← All vessels
UACC HARMONY
UACC HARMONY is a 2005 tank ship. The Coast Guard has recorded 20 inspections since 2006, most recently in September 2021, along with 12 deficiencies and 6 operational controls.
Records from 2006 to 2021. Most recent: inspection, 6 September 2021.
- Built
- 2005
- Last inspected
- 6 September 2021
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 12 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9288289 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FZK8
803872
Flag
PANAMA
—
Maury page id
psix-803872
Inspections, by type
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it28059 - Convention (Subpart B), Gross Ton
28059 - Simplified, Gross Ton
11645 - Simplified, Net Ton
11645 - Convention (Subpart B), Net Ton
54780 - Displacement, Ton
45913 - Dead Weight, Metric Ton
28059 - Simplified, Gross Ton
11645 - Simplified, Net Ton
11645 - Convention (Subpart B), Net Ton
54780 - Displacement, Ton
45913 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
6 September 2021
COC-TVE Renew · Ballast Water Examination · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7295310
5 May 2016
Administrative Inspection · COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5866666
27 January 2009
PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3399683
25 January 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3399732
23 July 2008
Ballast Water Examination · COC-TVE Renew · ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3276634
13 November 2007
ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3097691
5 May 2007
Spot Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2922892
21 April 2007
Deficiency Check · ISM Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2912161
18 April 2007
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2910339
8 February 2007
ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · COC-TVE Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2868069
16 January 2007
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2857003
13 January 2007
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2855341
25 March 2006
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2609395
24 March 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2609128
8 February 2006
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2581405
25 January 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2573352
24 January 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2572110
18 January 2006
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2569323
17 January 2006
MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · COC-TVE Renew · MARPOL Annex V Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2564009
17 January 2006
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2568187
Deficiency record · 12
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 6 September 2021
Resolved
All lifesaving appliances and arrangements shall comply with the applicable requirements of the code. Food rations as described in paragraph 4.1.5.1.18 totaling not less than 10,000 KJ for each person the lifeboat is permitted to accommodate. Vessel requires 50 total rations, 25 per lifeboat. 14 total food rations have a broken vacuum seal, 05 on the port lifeboat and 09 on the starboard lifeboat.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 23 July 2008
Resolved
The #1 port overfill alarm is malfunctioning; Unit showing continuous alarm status. Provide technician report verifying sensor for alarm is working properly.
Deck/Cargo › Inert Gas System › Boiler Uptake
Issued 22 April 2007
Resolved
Ships boiler automatic burning mode doesn't work. This supplies inert gas and the O2 content of the boiler gas can only be controlled by manual mode which does not function as designed. Rectify deficiencies prior to departure from port to the satisfaction of CG and class.
Engineering › Steam Boiler (auxiliary/waste heat) › Fan
Issued 22 April 2007
Resolved
Engine room log stated on 7 April 07 vessel removed aux blower fan motor for aux boiler and doesn't state when repaired. Vessel must provide technician reports for both boiler ops and forced draft fan. Rectify deficiencies prior to departure from port to the satisfaction of CG and class.
Documentation › Safety Management System › Safety/Environmental Protection Policy
Issued 20 April 2007
Resolved
See "FormA&B20Apr07Detention" in Documents section. Ship has been detained until the deficiency has been rectified to the satisfaction of Class.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 20 April 2007
Resolved
See "FormA&B20Apr2007Detention" in Documents section. Ship has been detained until the deficiency has been rectified to the satisfaction of the Administration.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 8 February 2007
Resolved
Bunker and cargo transfer procedures do not meet requirements for oil transfer in the navigable waters of the Unitd States. Provide to Coast Guard prior to cargo operations.
Documentation › Logs/Records › Oil Record Book
Issued 8 February 2007
Resolved
Entries in ORB are not made in accordance with MARPOL; many entries have not been signed by the person in charge; two or more separate operations have been logged as one entry; the codes used for collection and disposal of oil residues are not correct. Correct to satisfaction of class/RO
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 8 February 2007
Resolved
Several documents used for essential procedures (firefighting maintenance, hotwork, enclosed space entry, ballast water handling, meter calibration) have been created by the crew and are not in accordance with or tracked within the SMS. The procedures for maintaining a safe atmosphere in pump room not followed & entry log book not filled out properly. Rectify to satisfaction of RO. ISM A/11
Documentation › Markings/Placards › Garbage Placard
Issued 8 February 2007
Resolved
The garbage placards posted throughout the ship are in conflict with labeling/color coding as outlined in the ship's garbage management plan. Correct to satisfaction of class/RO
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 8 February 2007
Resolved
The crew isn't familiar w/proper maintenance & testing of IGS. Crewmbrs unfamiliar w/calibration of O2 sensor. C/E doesn't have test procedures for gas high temp alarm, & is unable to demonstrate if operable/ever tested. Must provide procedures for testing O2 & gas high temp & show proficiency in IGS operation prior to cargo for CG. ISM A/10.3 FSS 15/2.4
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 14 January 2006
Resolved
Retain all oily waste slops on board and discharge to approved reception facilities until proper operation of the Oil Discharge monitoring equipment (ODME) is provided to the satisfaction of class but no later than 17Feb2006.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.