Records from 2016 to 2026. Most recent: inspection, 22 June 2026.
Inspection history · 17
22 June 2026
Drydock Exam · Vessel Attendance
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8387172
3 March 2026
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8306167
5 March 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8088810
24 June 2024
Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7941399
19 January 2024
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7851531
15 March 2023
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7651822
29 June 2022
Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7477214
28 February 2022
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7398354
5 March 2021
Deficiency Check · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7149460
18 September 2020
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7032286
12 August 2020
Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7006367
29 August 2019
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6790743
23 August 2018
Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6520998
2 August 2018
Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6482502
12 July 2018
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6477042
5 September 2017
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6237422
28 June 2016
COI Inspection · DAPI Audit · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5910088
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 February 2022
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Office in Charge, Marine Inspection. Replace mounting brackets for portable fire extinguishers located forward and amidship. 46 CFR 181.520
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 March 2022
Resolved 25 March 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 February 2022
Resolved
Each connection to a conductor or a terminal part of a conductor mut be made with an enclosure or (1) a pressure type connector. Numerous dead ended wires discovered under main console, remove wires or cap properly. 46 CFR 183.340
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 March 2022
Resolved 31 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2021
Resolved
AN ADULT LIFEJACKET MUST BE PROVIDED ON BOARD FOR EACH PERSON CARRIED ON BOARD A VESSEL. PROVIDE A LIFEJACKET FOR EACH PERSON ON BOARD IN ACCORDANCE WITH COI. VESSEL IS RESTRICTED TO 19 PASSENGERS UNTIL LIFEJACKETS ARE BROUGHT ON BOARD.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2021
Resolved 24 March 2021
Resolution: Owner provided receipt for proof of purchase for 10 adult life jackets on 24MAR and has since placed them in service on the vessel. The vessel can now carry the amount of persons alloted as per COI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 March 2021
Resolved
A VESSEL MUST CARRY ONE WATERLIGHT. PROVIDE A FLOATING WATERLIGHT IN ACCORDANCE WITH COI. RESTRICTED TO DAYLIGHT OPERATIONS.
46 CFR 180.70(d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2021
Resolved 24 March 2021
Resolution: Vessel obtained a brand new and working waterlight for RLB.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 5 March 2021
Resolved
BATTERIES MUST BE SECURED TO PROTECT AGAINST SHIFTING AND FREE FROM EXPOSURE TO WATER SPRAY. SECURE BATTERIES TO PREVENT SHIFTING.
46 CFR 183.350(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2021
Resolved 24 March 2021
Resolution: Batteries are secured to the trays mounted to the deck.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 March 2021
Resolved
EACH VESSEL MUST BE EQUIPPED WITH AT LEAST TWO OPERABLE PORTABLE BATTERY LIGHTS. PROVIDE TWO OPERABLE PORTABLE BATTERY LIGHTS.
46 CFR 183.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2021
Resolved 24 March 2021
Resolution: Owner provided proof of two operable portable lights (flashlights) for the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 March 2021
Resolved
ELECTRICAL EQUIPMENT AND INSTALLATION MUST BE SUITABLE FOR THE ROLL, PITCH, AND VIBRATION OF THE VESSEL UNDERWAY. REPLACE FORWARD OVERHEAD LIGHT FIXTURE COVER. SECURE SPEAKER OVERHEAD FORWARD PASSENGER SEATS.
46 CFR 176.810
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2021
Resolved 24 March 2021
Resolution: Speaker is secured overhead.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 March 2021
Resolved
OWNER/OPERATOR MUST CONDUCT INSPECTIONS AND TESTS OF PORTABLE FIRE EXTINGUISHERS MONTHLY AND ANNUALLY AS REQUIRED BY CH 4 OF NFPA 10. PROVIDE EVIDENCE OF INSPECTIONS AS PER CH 4 OF NFPA 10.
46 CFR 176.810
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2021
Resolved 24 March 2021
Resolution: Owner provided proof of Fire Extinguisher inspections by Safety First.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 August 2020
Resolved
The Owner or managing operator shall make a vessel availble for drydock examination.
Vessel exceeded drydock inspection date (30Jun2020).
46CFR176.600
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2020
Resolution: Conducted successful drydock on 12Aug2020.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 August 2019
Resolved
Employers must ensure that they and their crewmembers
meet the requirements of the chemical testing program.
Provide evidence, to the satisfaction of the attending
marine inspector, of: Random testing, Arrangements for incident and reasonable cause, EAP, MIS, and employee enrollment. 46 CFR 16.203 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2019
Resolved 27 September 2019
Resolution: O/O provided proof of random testing, alcohol test devices, EAP, MIS report (2018), and employee enrollment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 August 2019
Resolved
An adult life jacket must be provided for each person
carried and a number of child size life jackets equal to
at least 10% of the number of persons permitted on board
must be provided on board a vessel.
02 Adult life jackets and 01 child life jacket were not
in a serviceable condition. Passenger count reduced to
24 adult persons and 02 persons less than ninety (90)
lbs. 46 CFR 180.71 (a)(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2019
Resolved 27 September 2019
Resolution: O/O purchased 02 adult and 01 child Type-1 life jackets.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 5 September 2018
Resolved
Radio is not connected to GPS. - 46CFR184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2018
Resolved 12 September 2018
Resolution: O/O requested route to be changed to not more than 1,000 feet from shore.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 September 2018
Resolved
No proof of servicing portable fire extinguishers was made available for inspector to review. Owner had no maintenance logs available. 46CFR189.25-20(a)(1)
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2018
Resolved 11 September 2018
Resolution: O/O provided pictures of proof of inspection for portable fire extinguisher via SSP inbox.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 September 2018
Resolved
Life line on ring life buoy does not meet requirements. 46CFR180.70(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2018
Resolved 24 September 2018
Resolution: O/O is using replacement life ring buoy with proper life line attached that meets requirements of 46 CFR 180.70(c).
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 September 2018
Resolved
No retroreflective material found on life ring buoys. 46CFR185.604(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2018
Resolved 24 September 2018
Resolution: O/O provided proof of purchase of new retro reflective tape along with pictures via SSP inbox.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 September 2018
Resolved
Expired burn cream, eye dressing, aspirin, and ammonia inhalants. 46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2018
Resolved 24 September 2018
Resolution: O/O provided proof of purchase and pictures of new first aid kit contents via SSP inbox.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 2 August 2018
Resolved
The owner/managing oeprator shall make a vessel available for drydock examinations, internal structural examinations. MI observed 01 and 03 stbd compartmentsunable to prove pressurization. 46CFR176.600
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 August 2018
Resolution: Successfully tested pontoons with appropriate equipment.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 July 2018
Resolved
The owner or managing operator shall make a vessel available for dry dock examinations; vessel must undergo a dry dock examination at least once every two years.
Operator failed to make vessel available for inspection prior to 30 June 2018, as required.
Complete credit dry dock prior to carrying passengers for hire. 46 CFR 176.600
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2019
Resolution: See activity 6482502 for DD completion.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 5 September 2017
Resolved
18 adult life jacket and 3 child life jacket missing, reduce passenger count to 6 adult and provide 18 adult and 3 child life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2017
Resolved 5 October 2017
Resolution: Owner provide all 18 adult and 3 child Lifejackets, all properly marked, deficiency cleared.
Lifesaving › Hand Flares › Quantity
Issued 5 September 2017
Resolved
2 flares missing, provide 2 red hand flares.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 September 2017
Resolved 5 October 2017
Resolution: Owner provide all 6 hand flares on board, deficiency cleared.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 28 June 2016
Resolved
Post emergency, fire, and heavy weather instructions IAW 46 CFR 185.510
Due 14 July 2016
Resolved 5 July 2016
Navigation › Piloting/Steering › Coast Guard Light List
Issued 28 June 2016
Resolved
Provide copies of light list IAW 46 CFR 184.420
Due 14 July 2016
Resolved 5 July 2016
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 28 June 2016
Resolved
Purchase 2 type-1 life jackets and reduce passenger count by 2 IAW 46 CFR 180.71(a)
Due 14 July 2016
Resolved 5 July 2016
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 28 June 2016
Resolved
Do not operate past demarcation line IAW Stability Letter
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 7 July 2016
Resolution: Sent new COI with correct route