← All vessels
OBERON
OBERON is a 2006 tank ship. The Coast Guard has recorded 9 inspections since 2006, most recently in July 2021, along with 2 deficiencies and 2 operational controls.
Records from 2006 to 2021. Most recent: operational control imposed, 2 July 2021.
- Built
- 2006
- Last inspected
- 1 July 2021
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 2 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9299721 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5PB5
804122
Flag
INDIA
—
Maury page id
psix-804122
Inspections, by type
…with no type recorded1
Years with a record
5 calendar years (2006–2021)
The 9 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it57243 - Convention (Subpart B), Gross Ton
32763 - Convention (Subpart B), Net Ton
106004 - Dead Weight, Ton
122969 - Displacement, Ton
32763 - Convention (Subpart B), Net Ton
106004 - Dead Weight, Ton
122969 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 9
1 July 2021
PSC A · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7241354
14 March 2010
COE-Dockside
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3692527
7 July 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3261503
17 June 2008
MARPOL Annex I Examination · COC-TVE Renew · MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3235238
12 July 2007
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2992509
10 July 2007
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2990401
3 July 2007
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2982194
14 February 2007
MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · COC-TVE Annual · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2871868
13 January 2006
MARPOL Annex I Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2568536
Deficiency record · 2
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 1 July 2021
Resolved
A secondary means of allowing full flow relief of vapour, air or inert gas mixtures shall be provided to prevent over-pressure or under-pressure in the event of failure arrangements. PSCO observed that the liquid level in P/V breaker was lower than what was required due to the pressure in the main IG line.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other cargo/timber/deck/construction
Issued 1 July 2021
Resolved
The venting system shall be provided with devices to prevent the passage of flame into the cargo tanks. The design, testing and location of these devices shall comply with the requirements established by the Administration based on the guidelines developed by the Organization. PSCO observed wrong flame screens installed on WBT tanks.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.