Records from 2011 to 2026. Most recent: inspection, 23 June 2026.
Inspection history · 37
23 June 2026
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8412576
18 April 2025
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8114044
17 April 2025
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8215124
8 April 2025
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8108092
23 January 2025
Bulk Liquid Transfer Monitor
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8068955
1 December 2024
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8042320
4 July 2024
Examination of Repairs · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7961165
29 June 2024
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7953381
21 June 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7939874
21 June 2024
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7981334
9 April 2024
Annual Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7892324
7 April 2023
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7648212
6 April 2023
In-Service Inspection · Administrative Inspection · Appeal
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7664180
8 March 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7647620
27 October 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7585060
12 April 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7429768
26 July 2021
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7268597
5 June 2021
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7221516
9 April 2021
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7173300
9 March 2021
Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7152681
1 July 2020
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6992791
11 May 2020
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6951368
9 March 2020
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6923010
10 January 2020
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6894937
26 September 2019
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6821586
25 September 2019
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6832403
25 April 2019
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6670186
26 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6548937
30 January 2018
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6349956
30 January 2018
Construction Oversight · Examination of Repairs · Drydock Exam · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6364881
11 June 2017
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6175984
10 June 2017
Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6174093
23 May 2017
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6153238
13 October 2016
Damage Survey · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6022016
23 May 2016
DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5884338
27 April 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5863188
11 February 2016
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5813173
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 23 June 2026
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. Light fixture in laz was broken. Fix light fixture and notify local OCMI.
46 CFR 183.410
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2026
Resolution: POC provided images. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 June 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found in laz and 03 DCV’s in the engine room were missing plates and showing exposed wires. Remove dead end wiring and update electrical plans.
46 CFR 183.200 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2026
Resolution: POC provided images. All SAT
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 June 2026
Resolved
An alarm for a fixed gas fire extinguishing system must be clearly and conspicuously marked “WHEN ALARM SOUNDS-VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED”. Where a different extinguishing agent is installed, that agent shall be marked in place of “carbon dioxide.”
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows:
(1) Spaces storing carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION.”.
(2) Spaces protected by carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” The reference to wintergreen scent may be omitted for carbon dioxide systems not required to have odorizing units and not equipped with such units.
46 CFR 185.612
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2026
Resolution: POC provided images. All SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2026
Resolved
Each vessel must have adequate emergency lighting fitted along the escape to the main deck from all passenger and crew accommodation spaces located below the main deck. 03 emergency lights in the passenger accommodation were inoperable. Replace emergency lighting and notify local OCMI.
46 CFR 183.432
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2026
Resolution: POC provided images. All SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2026
Resolved
Each ring life buoy on a vessel must: Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Mi found port and stbd ring life buoy to be no longer serviceable. Replace ring life buoy.
46 CFR 180.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2026
Resolution: POC provided images. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 18 April 2025
Resolved
Vessel's port propeller struck a submerged log while underway. Provide servicing report of repairs and balancing of the port propeller prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 23 April 2025
Resolution: Recieved report, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 18 April 2025
Resolved
Vessel's port propeller struck a submerged log while underway. Provide servicing report of port shaft testing prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 23 April 2025
Resolution: Received report, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 April 2025
Resolved
Remote fuel shutoff valve failed during testing. Repair/replace the fuel shutoff valve and demonstrate operation to the attending Coast Guard marine inspector. Cite: 46 CFR 182.455(b)(4)
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2025
Resolved 10 April 2025
Resolution: Remote fuel shut off operational.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 April 2025
Resolved
There was no fire detector in the engine room. Install an integrated fire detector in the engine room and demonstrate operation to the attending Coast Guard marine inspector. The detector must be in compliance with 46 CFR 181.450. Cite: 46 CFR 181.405(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2025
Resolution: Detector installed in engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 December 2024
Resolved
Vessel reported that its starboard shaft is cracked and is causing a vibration when run. Vessel must repair or replace the affected shaft.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2024
Resolution: Shaft was replaced with aquamet 22.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 9 April 2024
Resolved
The Laz hatch was found to be missing the gasket. Make hatch water tight.
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: Hatch gasket was replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 9 April 2024
Resolved
The ER escape hatch was found to be inoperable from the inside. Provide means to operate escape hatch from inside the compartment.
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: The wrong hatch was installed, vessel crew changed out with proper hatch.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 April 2024
Resolved
Extension cord cable was found wired to a light fixture on the main deck port side closet. Provide proper boat cable for the light fixture.
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: Extension cord was removed.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 9 April 2024
Resolved
Vessel's steering was inoperable due to hydraulic ram maintenance. Prove proper operation of steering.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 April 2024
Resolution: Rebuilt ram was installed and video was sent to SSD.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 April 2024
Resolved
Ring buoy light was found inoperable. Prove operation of light.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 April 2024
Resolution: Light was repaired.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 9 April 2024
Resolved
Vessel was unable to get underway. Preform underway man overboard drills and provide proof to SSD.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 April 2024
Resolution: Drills were conducted, logged, and video sent to SSD.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 April 2023
Resolved
03 ring buoys were missing retro reflective tape. Add retro reflective tape to front and back of all ring buoys at "four corners".
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2023
Resolved 27 April 2023
Resolution: Witnessed pictures of the corrected ring buoys.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 12 April 2022
Resolved
Vessel's EPIRB had an expired battery and could not be replaced. Replace and register the new EPIRB with NOAA. Vessel is restricted to no more than 3NM from shore until this deficiency is rectified.
Action required: 705 - Other - as specified
Resolved 13 April 2022
Resolution: EPIRB replaced - Received a copy of the new registration via email.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 12 April 2022
Resolved
The vessel's fire stations did not have spanner wrenches. Provide a spanner wrench at each fire station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2022
Resolved 13 April 2022
Resolution: Received email with picture of the new spanner wrenches.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 April 2022
Resolved
The vessel's fire pump gauge is stuck. Replace the gauge on the fire pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 13 April 2022
Resolution: Received email with picture of the new guage.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2019
Resolved
Electrical equipment must be installed and maintained to protect passengers, crew and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock. Correct the following: (1)Label all sub-panels (2)Provide blanks for missing breakers (3)Provide switchboard with latching/securing device. (4)Make permanent repairs to "main panel", make cover able to latch/close. (6)Make main panel free of any openings. (7)Remove surge protect @ TV (8) Properly wire and install outlets in crew cabins.
Action required: 705 - Other - as specified
Due 25 November 2019
Resolved 10 January 2020
Resolution: Pictures received.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 September 2019
Resolved
Complete but simple instructions for the operation of the fixed gas fire-extinguishing system must be located in a conspicuous place at or near each pull box and stop valve and in the space where the cylinders are stored. Crew member did not know location of E/R CO2 system remote pull. Label with "Engine Room CO2 remote pull station - On master's order - Pull handle - Cover ventilation - Close remote fuel shutoffs."
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2019
Resolved 25 November 2019
Resolution: MI attended.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 September 2019
Resolved
Provide additional ladder rungs above main deck on forward emergency escape. Mark two rungs below deck at hinge locations with "PULL"
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2019
Resolved 25 November 2019
Resolution: MI attended
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 September 2019
Resolved
Move "EMERGENCY EXIT - KEEP CLEAR" markings closer to emergency exit hatch in galley.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2019
Resolved 25 November 2019
Resolution: MI attended.
09 - Working and Living Conditions › 091 - Living Conditions › Cold room
Issued 25 April 2019
Resolved
Repair escape plunger in starboard freezer.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 2 May 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 26 September 2018
Resolved
ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 10 May 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 July 2018
Resolved
Provide fire service report.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 July 2018
Resolution: cert provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 6 July 2018
Resolved
Install captive chains on hatches exposed to the weather.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 July 2018
Resolution: installed chains.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 July 2018
Resolved
Installing approve first aid kit on the vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 July 2018
Resolution: Installed kit.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 6 July 2018
Resolved
Properly mounted light cover in forward berthing compartment, port side.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 July 2018
Resolution: deadlight installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 July 2018
Resolved
Install hardware on starboard side pilot house door.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 July 2018
Resolution: Hardware installed.
Engineering › Steering Gear System › Actuator
Issued 10 June 2017
Resolved
Loss of steering; unknown cause.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2017
Resolved 15 June 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 13 October 2016
Resolved
Demonstrate proper operation of the port port MDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 15 October 2016
Resolution: Operatiionally tested the port MDE SAT
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 11 February 2016
Resolved
Make efective repairs to the portside main propulsion shaft prior to getting underway with passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 February 2016
Resolution: Effective repairs made and operational test witnessed.