13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 May 2026
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Starboard aft fuel tank valve has slow leak.
46 CFR 143.220(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2026
Resolved 20 July 2026
Resolution: Operator submitted pictures of satisfactory repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 May 2026
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Outlet above the starboard main engine has broken plug logged in outlet posing a safety risk.
46 CFR 143.400(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2026
Resolved 20 July 2026
Resolution: Operator submitted pictures of replaced outlet.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 May 2026
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Remove all waste receptacles that meet the standard, and replace with proper noncombustible.
46 CFR 144.425
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2026
Resolved 20 July 2026
Resolution: Recieved pictures from operator with non-combustible garbage cans onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2026
Resolved
Each lifebuoy on a towing vessel must: Be marked in block capital letters with the name of the vessel. Lifebouy markings were wasted and could not read.
46 CFR 141.360(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2026
Resolved 20 July 2026
Resolution: Lifebuoys remarked accordingly per operator email/pictures.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 21 May 2026
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. The port aft window and A/C unit are not watertight.
46 CFR 140.610(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2026
Resolved 20 July 2026
Resolution: Operator emailed pictures of new gaskets around effected windows.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 11 June 2025
Resolved
46 CFR 144.605 Means to stop fans and close openings.
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces.
Machinery space fans and vents did not have a means for closing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2025
Resolved 14 July 2025
Resolution: Photographic evidence of new vent closures provided by operator
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 June 2024
Resolved
The Rules concerning day shapes shall be complied with by day. The vessel was found to not possess the required day shapes for the employment of the vessel. Procure the required day shapes prior to conducting commercial operations.
Action required: 10 - Deficiency Rectified
Resolved 6 June 2024
Resolution: Owner provided photographic evidence of the proper shape and quanitiy of dayshapes on the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 June 2024
Resolved
Portable and semi-portable fire extinguishers must be inspected maintained and tested with the frequency specified by NFPA 10. It was found that the vessel's portable and semi-portable fire extinguishers were not inspected on a monthly basis. Fire extinguisher monthly checks to be accomplished and documented prior to commercial operations.
Action required: 10 - Deficiency Rectified
Resolved 6 June 2024
Resolution: Owner provided photographic evidence of completion and documentation of the required mainetnance.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 6 June 2024
Resolved
Each immersion suit must be marked in such a way as to identify the person or vessel to which it belongs. It was found that the immersion suits were not properly marked. Properly mark immersion suits prior to commercial operations.
Action required: 10 - Deficiency Rectified
Resolved 6 June 2024
Resolution: Owner provided photographic evidence of the proper markings on the immersion suits.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 June 2024
Resolved
The emergency duties and duty stations must be posted at each operating station. It was found that emergency duties and duty stations were not posted in the wheelhouse.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2024
Resolution: Emergency duties and duty stations were visually sighted to be posted in the wheelhouse.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 6 June 2024
Resolved
A mariner's TWIC must be produced to verify identity when required by an authorized official. It was found that the vessel master's TWIC was expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2024
Resolution: Master provided a current TWIC for review.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 6 June 2024
Resolved
Survival craft must be marked with the name of the vessel, hailing port, and number of persons. It was found that the inflatable liferaft's identification card was not properly filled out.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2024
Resolution: Identification card was updated with the vessel informarion.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 June 2024
Resolved
Bilge alarms must be visible and audible at each operating station. It was found that the bilge level alarm and the hydraulic level alarms were backwards.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2024
Resolution: Alarm wiring was corrected and demonstrated to the MI.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 June 2024
Resolved
The design of the fire detection system must be certified and inspected by a registered professional engineer with experience in fire detection systems. The vessel was unable to produce evidence of certification and inspection by a registered professional engineer.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2024
Resolved 29 July 2024
Resolution: Owner provided objective evidence of a previous PE acceptance.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 June 2024
Resolved
Fire detection systems must be inspected at least once every twelve months. Additionally records of inspections and tests must be recorded in the TVR, offical logbook, or TSMS as applicable. It was found that the fire detection system had not been inspected within the previous twelve months. It was also found that the vessel did not have documentation of any previous inspection and testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2024
Resolved 17 July 2024
Resolution: Objective evidence of annual servicing received to the satisfaction of the attending MI.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 11 May 2022
Resolved
Vessel not equipped with required alarm for high bilge levels at operating station.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 24 August 2022
Resolution: Witnessed operation of high level alarms from engine room and bridge.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 11 May 2022
Resolved
Unable to demonstrate operational status of bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 24 August 2022
Resolution: Witnessed operational test of bilge pump.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 November 2020
Resolved
EACH TOWING VESSEL MUST HAVE EITHER A SELF-PRIMING, POWER-DRIVEN, FIXED FIRE PUMP, A FIRE MAIN, AND HOSES AND NOZZLES IN ACCORDANCE WITH PARAGRAPHS (A) THROUGH (D) OF THIS SECTION; OR A PORTABLE PUMP, AND HOSES AND NOZZLES, IN ACCORDANCE WITH PARAGRAPHS (E) AND (F) OF THIS SECTION. THE VESSELS FIRE PUMP WAS INOPERABLE.
46CFR142.325
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2021
Resolution: Resolved to satisfaction of attending marine inspectors.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 18 November 2020
Resolved
A REMOTE FUEL SHUTOFF VALVE SHALL BE INSTALLED ON ANY FUEL LINE THAT SUPPLIES FUEL DIRECTLY TO A PROPULSION ENGINE OR GENERATOR PRIME MOVER. THREE OF THE FOUR REMOTE FUEL SHUTOFF VALVES WERE NOT INSTALLED.
46CFR143.260(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2021
Resolution: Resolved to satisfaction of attending marine inspectors.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 18 November 2020
Resolved
SURVIVAL CRAFT SHALL BE STOWED IN ACCORDANCE WITH 199.130 OF THIS CHAPTER. THE HYDROSTATIC RELEASE UNIT FOR THE INSTALLED INFLATABLE LIFERAFT WAS EXPIRED.
46CFR141.310
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2021
Resolution: Resolved to satisfaction of attending marine inspectors.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 18 November 2020
Resolved
THE PERSON IN CHARGE OF A DOCUMENTED VESSEL SHALL ENSURE THAT THE ORIGINAL CERTIFICATE OF DOCUMENTATION IS ON BOARD THE VESSEL.
46CFR67.313
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2021
Resolution: Resolved to satisfaction of attending marine inspectors.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 November 2020
Resolved
A VESSEL OF GREATER THAN 26-FT, LESS THAN 79-FT SHALL CARRY A MIN. OF TWO LIFEBUOYS LOCATED ON OPPOSITE SIDES OF THE VESSEL. LIFEBUOYS ONBOARD WERE NOT SERVICEABLE.
46CFR141.360(a)(2)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2021
Resolution: Resolved to satisfaction of attending marine inspectors.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 November 2020
Resolved
AT LEAST TWO LIFEBUOYS ON A VESSEL OVER 26-FT SHALL BE EQUIPPED WITH A FLOATING ELECTRIC WATERLIGHT. THE ELECTRIC WATERLIGHTS ON BOARD WERE IN A DETERIORATED CONDITION, ONE HAVING BEEN ELECTRICAL TAPED TOGETHER AND NEITHER HAVING BATTERY INSTALL/EXPIRATION DATES MARKED.
46CFR141.360(c)(2)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2021
Resolution: Resolved to satisfaction of attending marine inspectors.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 November 2020
Resolved
CLOSURES SHALL BE PROVIDED TO ENSURE ALL HULL PENETRATIONS ARE CLOSED, PROVIDING PROPER PROTECTION FOR THE INTENDED ROUTE. VESSEL HAD MULTIPLE AREAS WHERE THE HULL/DOORS WERE COMPROMISED BY AN INSTALLATION, DETERIORATED GASKETS FOR ALL WATERTIGHT DOOES OR DETERIORATED METAL. PROVIDE A REPAIR PROPOSAL TO ENSURE THAT THE SHIP'S ENVELOPE IS WATER AND WEATHERTIGHT.
46CFR144.320(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2021
Resolution: Resolved to satisfaction of attending marine inspectors.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 18 November 2020
Resolved
THE OWNER/MANAGING OPERATOR MUST PROVIDE SATISFACTORY EVIDENCE OF THE REQUIRED SERVICING OF FIRE SAFETY EQUIPMENT TO THE C.G. MARINE INSPECTOR. THE VESSEL HAD NO SERVICING/MAINTENANCE RECORDS FOR THE FIRE SAFETY SYSTEMS DATED AFTER 2017.
46CFR142.240(a)(1)(iv)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2021
Resolution: Resolved to satisfaction of attending marine inspectors.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 18 November 2020
Resolved
PIPING AND MACHINERY COMPONENTS THAT EXCEED 220 °C (428 °F), MUST BE INSULATED. THE EXHAUST PIPING IN THE ENGINE ROOM HAD DUCT TAPE OVER THE LAGGING, PREVENTING THE ATTENDING [name withheld] THE MATERIAL CONDITION OF THE LAGGING AND POSING A POTENTIAL FIRE HAZARD.
46CFR143.220(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2021
Resolution: Resolved to satisfaction of attending marine inspectors.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 November 2020
Resolved
A FIRE DETECTION PANEL MUST DRAW POWER FROM TWO SOURCES. THE FIRE DETECTION PANELS BATTERY BACKUP WAS DEAD.
46CFR142.330(a)(5)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2021
Resolution: Resolved to satisfaction of attending marine inspectors.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 November 2020
Resolved
A VESSEL ON AN LBS/COASTWISE ROUTE SHALL HAVE AT LEAST 6 DAY/6 NIGHT VISUALDISTRESS SIGNALS. THE VESSEL ODID NOT HAVE THE REQUIRED TOTAL OF DISTRESS SIGNALS ON BOARD.
46CFR141.370
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2021
Resolution: Resolved to satisfaction of attending marine inspectors.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 November 2020
Resolved
A VESSEL OPERATING ON A COASTWISE ROUTE SHALL HAVE AN EPIRB, INSTALLED IN A FLOAT-FREE ARRANGEMENT. THE EPIRB HAD AN EXPIRED REGISTRATION AND THE HYDROSTATIC RELASE UNIT HAD EXPIRED IN 2019.
46CFR141.380
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2021
Resolution: Resolved to satisfaction of attending marine inspectors.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 November 2020
Resolved
VESSELS SHALL HAVE A HEALTH AND SAFETY PLAN. NO HEALTH AND SAFETY PLAN WAS ON BOARD THE VESSEL.
46CFR140.500
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2021
Resolution: Resolved to satisfaction of attending marine inspectors.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 November 2020
Resolved
EVERY TOWING VESSEL OF GREATER THAN 26-FEET IN LENGTH MUST HAVE A RADIOTELEPHONE IN COMPLAINCE WITH THE BRIDGE TO BRIDGE ACT. THE VESSEL DID NOT HAVE A VALID BRIDGE TO BRIDGE OR RADIOTELEPHONE CERTIFICATE.
33CFR26.03
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2021
Resolution: Resolved to satisfaction of attending marine inspectors.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 November 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2021
Resolution: Resolved to satisfaction of attending marine inspectors.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 18 November 2020
Resolved
VESSELS SHALL HAVE AN ILLUMINATED MAGNETIC COMPASS & DEVIATION TABLE. NO DEVIATION TABLE WAS PRESENT & LIGHT WAS NOT MOUTNED/FALLING OFF.
46CFR140.725(d)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2021
Resolution: Resolved to satisfaction of attending marine inspectors.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 18 November 2020
Resolved
TOWING VESSELS SHALL KEEP A TOWING VESSEL RECORD OR OFFICIAL LOGBOOK, LOGGING THE ITEMS REQUIRED IN 140.915. THE VESSELS LOGBOOK DID NOT CONTAIN THE REQUIRED ITEMS.
46CFR140.910
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2021
Resolution: Resolved to satisfaction of attending marine inspectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 November 2020
Resolved
PRESSURE VESSELS SHALL BE FITTED WITH ONE OR MORE SPRING-LOADED RELIEF VALVES TO PREVENT OVER THE TANK FROM EXCEEDING MAWP BY MORE THAN 10%. THE PRESSURE VESSELS RELIEF VALVE HAD NO MARKINGS TO INDICATE ITS RELIEVING PRESSURE.
46CFR143.300(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2021
Resolution: Resolved to satisfaction of attending marine inspectors.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 18 November 2020
Resolved
VESSELS OPERATING ON COASTWISE ROUTES SHALL HAVE LINE-THROWING DEVICES APPROVED UNDER 160.040. THE VESSEL HAD NO LINE-THROWING DEVICES ON BOARD.
46CFR141.385
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2021
Resolution: Resolved to satisfaction of attending marine inspectors.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 November 2020
Resolved
VESSEL SHALL CARRY CURRENT CHARTS AND PUBLICATIONS FOR THEIR INTENDED VOYAGE. VESSELS HAD NO CURRENT PUBS AVAILABLE.
46CFR140.705
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2021
Resolution: Resolved to satisfaction of attending marine inspectors.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 21 July 2020
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Inflatable liferaft maintenance is overdue. Provide documentation of liferaft servicing.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 March 2021
Resolution: Recieved Servicing invoice and documentation for proper install. def cleared
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 21 July 2020
Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. Starboard generator forward rotating machinery does not have protective cover. Install protective cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 March 2021
Resolution: Recieved documentaion of the installment of proper guards in place.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 July 2020
Resolved
Each vessel must be designed and constructed to minimize fire hazards insofar as reasonable and practicable. Fuel filter housings in engineroom did not have flame impingement bowls. Install flame impingement bowls on fuel filter housings in engineroom.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 March 2021
Resolution: Recieved invoice of new fuel filter flame impingement bowl. def cleared.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 23 October 2018
Resolved
Vsl is broadcasting invalid MMSI and Vsl is broadcasting Invalid Call Sign
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 March 2021
Resolution: Resolved to satisfaction of attending marine inspectors.
Navigation
Issued 21 March 1997
Resolved
PROVIDE UPDATED NAV RULES.
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Lifesaving
Issued 21 March 1997
Resolved
RENEW STBD LIFERING.
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Navigation
Issued 21 March 1997
Resolved
PROVIDE RESTRICTED IN ABILITY TO MANEUVER LIGHTS. IF VESSEL SUPPLIES DOCUMENTATION FROM OWNER THAT VESSEL WILL NOT GO BEYOND 3NM VESSEL DOES NOTNEED UL1104 STANDARD LIGHTS.
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Documentation
Issued 19 August 1996
Resolved
PROVIDE PROOF OF VALID CERTIFICATE OF DOCUMENTATION ON BOARD VESSEL.
Condition: Unknown
Due 11 September 1996
Resolved 12 September 1996
Documentation
Issued 19 August 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 11 September 1996
Resolved 12 September 1996
Accommodation/Occupational Safety
Issued 19 August 1996
Resolved
PROVIDE PROPER MSD FOR UTV
Condition: Unknown
Due 11 September 1996
Resolved 12 September 1996
Navigation
Issued 19 August 1996
Resolved
Navlights operable, however do not meet UL 1104 as per NAVRULS, Provide proper lights.
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Engineering
Issued 19 August 1996
Resolved
provide proof that both MDE operate satisfactorily
Condition: Unknown
Due 11 September 1996
Resolved 13 September 1996
Documentation
Issued 19 August 1996
Resolved
Provide evidence of drug and alcohol program aborad vessel
Condition: Unknown
Due 11 September 1996
Resolved 13 September 1996
Documentation
Issued 19 August 1996
Resolved
provide proof of waste management plan on board vessel
Condition: Unknown
Due 11 September 1996
Resolved 13 September 1996
Fire Fighting
Issued 19 August 1996
Resolved
Repair improperly stowed fire extinguisher stowed iwo galley
Condition: Unknown
Due 11 September 1996
Resolved 13 September 1996
Navigation
Issued 19 August 1996
Resolved
provide copy of NAVRULS aboard vessel
Condition: Unknown
Due 11 September 1996
Resolved 13 September 1996