Records from 2016 to 2026. Most recent: inspection, 30 April 2026.
Inspection history · 47
30 April 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8358946
28 April 2026
Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8357580
23 April 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8354830
11 April 2026
PSC B · COC-CVE Quarterly
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8341284
11 September 2025
COC-CVE Annual · PSC A
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8230391
17 July 2025
PSC B
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8188356
11 June 2025
PSC B
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8157151
11 June 2025
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8158213
8 May 2025
PSC B · COC-CVE Quarterly
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8131367
26 September 2024
Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8010104
12 September 2024
COC-CVE Annual · PSC A
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7998086
21 April 2024
PSC B · COC-CVE Quarterly
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7896479
16 October 2023
PSC B · COC-CVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7809681
8 May 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7684078
22 April 2023
PSC B · COC-CVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7672050
21 April 2022
COC-CVE Annual · Ballast Water Examination · PSC A · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7434297
18 November 2021
Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 7353449
17 April 2020
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6998752
28 October 2019
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6875874
14 October 2019
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6834304
28 September 2019
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6865638
4 September 2019
ISM Exam · In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6804034
14 August 2019
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6822019
15 July 2019
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6764002
1 July 2019
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6742727
19 June 2019
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6724444
9 June 2019
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6708847
2 June 2019
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6708792
15 May 2019
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6679617
29 April 2019
Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6668990
26 September 2018
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6581044
21 September 2018
Type not recorded
No type recorded · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6547622
20 September 2018
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6544912
30 August 2018
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6574913
23 August 2018
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6520811
14 August 2018
Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6559396
13 August 2018
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6603594
6 August 2018
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6505246
4 August 2018
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6504160
31 July 2018
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6564103
21 July 2018
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6514234
28 April 2018
Ballast Water Examination · COC-CVE Annual · ISPS II Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6399556
22 April 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6398758
18 August 2017
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6269845
19 July 2017
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6256574
16 April 2017
ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6127739
17 April 2016
COC-CVE Annual · ISPS II Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 5855711
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 11 April 2026
Resolved
Muster and embarkation stations shall be adequately
illuminated by lighting. PSCO observed at least 3 sets of
embarkation lightings not illuminated.
74 SOLAS 20 III/11.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2026
Resolved 28 April 2026
Resolution: Class attended virtually and provided report clearing the def.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 September 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Port rescue boat did not start upon actuation of engine.
74 SOLAS 20 III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 September 2025
Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of a force in the direction of escape flow. PSCO observed thumb type latches on multiple escape doors deck 10 child area.
74 SOLAS 20 II-2/13.3.6.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2025
Resolved 20 January 2026
Resolution: Received Class Exemption Certificate
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 September 2025
Resolved
A fixed fire-extinguishing system, required by this chapter shall comply with the provisions of the Fire Safety Systems Code. In accommodation and service spaces the sprinklers shall come into operation within the temperature rance fom 68 C to 79 C. PSCO observed empty ampule on sprinkler head, ivo section valve 11,16,17 station.
74 SOLAS 20 II-2/10.4.1.1
Action required: 10 - Deficiency Rectified
Resolved 11 September 2025
Resolution: Rectified to the satisfation of attending Marine Inspector
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 June 2025
Resolved
Ignition sources shall be restricted; In electrical locker 10.3.20, PSCO observed open paint cans, rags and other painting debris left unattended, with no worker nearby. 74SOLAS20 II-2/4.1.4 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2025
Resolution: Flamable liquid was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 June 2025
Resolved
Cylinders must always be secured, and when not in use, they must be stowed in a rack... PSCO observed 12 nitrogen and
refrigerant gas bottles secured to railing (engine room) that is not designed as a securing point for compressed gas bottles. 46CFR147.60(b)
Action required: 15 - Rectify deficiencies by next port
Resolved 12 June 2025
Resolution: Cylinders were secured withe appropriate lashing.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 June 2025
Resolved
The purpose of this regulation is to provide means of escape so that persons on board can safely and swiftly escape to the lifeboat and liferaft embarkation deck. For this purpose, the
following functional requirements shall be met: .1 safe escape routs shall be provided; Behind FSD 08.4.26, PSCO obsereved a closet storing houseware that prevented the entry/exit door from opening all the way, additionally the path thughout the space was severely obstructed with goods. 74SOLAS 20 II-2/13.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 June 2025
Resolution: area was cleared and class report provided; all sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 May 2025
Resolved
Parties responsible for fire extinguishing shall be
!Organized. These parties shall have the capability to complete their duties at all times while the ship is in service. A member of Attach Fire Team 1, as observed during the drill, ??dentified as having low-flow to his SCBA, after entering the !fire area.
74 SOLAS 2011-2/15.2.1 3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2025
Resolution: Additional training provided to fire team 1
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 May 2025
Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation,or where it is possible to assign two or more classifications to a space, it shall be treated as a space within the relevant category having the most stringent boundary requirements. NC machinery spaces 1/1.01, 2/4, and 1/2 iare identified as category (I 0) spaces, and were found to have combustibles stowed in the spaces.
74 SOLAS 20 ll-2/19.2.2.3.2.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2025
Resolution: Combustible material was removed and stored in correct space Cat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 May 2025
Resolved
Fire doors in main vertical z.one bulkheads, galley ooundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5° opposing closure. PSCO observed FSD 1.1.69, FSD 04.7.03, FSD 04.6.05, FSD 3.1.82 would not close as intended.
74SOLAS2011-2/9.4.1.1.5.l
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2025
Resolution: Door adjusted to close properly.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 May 2025
Resolved
Cabin doors in "8" class divisions shall be of a self-closing ??pe. Hold-back hooks are not pennitted. Three crew bibins, doors 8096, B 110, and 8098 were observed to not be self closing.
74SOLAS20 II-2/9.4.1.2.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2025
Resolution: Door were made to slef close.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 May 2025
Resolved
The following functional requirements shall be met: escape
routes shall be maintained in a safe condition, clear of
obstacles. The passageway near room A.3.09 was Mentified as an esacpe route, and was incorrectly being used to stow luggage and other supplies.
74 SOLAS 20 11-2/13.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2025
Resolution: All stowed items removed from the egress route.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 8 May 2025
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Four (4) stairway guides in crew stairways forward 7,8,9 and aft 6
were not familiar with ship's emergency procedures for passengers returning to their cabins during an abandon ship scenario.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2025
Resolution: Training conducted with members who failed to meet standard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 May 2025
Resolved
Waste receptacles shall be constructed of on-combustible materials with no openings in the sides or bottom. PSCO obsetved two garbage cans in galley areas
n deck 1 and 3 where combustible waste was stowed in plastic garbage cans.
74 Solas 20 II-2/4.4.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2025
Resolution: Plastic garbage cans removed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 May 2025
Resolved
The means of escape, including stairways and exits, shall be
marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. The
marking must enable passengers/crew to identify the
outes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be of photo luminescent material or marked by lighting. PSCO obseived low location lighting erroneously indicating a door on deck 3, starboard side aft,
exit by the dining room entrance. Additionally, PSCO o
bsetved low location lighting erroneously indicating a door o
n deck 3, port side, by the mid ship stair.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2025
Resolution: Recieved Class report that the low level light in question was removed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 May 2025
Resolved
In interior locations in passenger ships carrying more than 36 passengers, fire hoses shall have necessary fittings and
tools for use kept in conspicuous postilions near hydrants.
the hydrant located as location 01.01 .29 was missing a spanner wrench.
74 SOLAS 20 II-2/10.2.3.1.1
Action required: 10 - Deficiency Rectified
Resolved 8 May 2025
Resolution: Spanner Wrench installed in location 01.01.29
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 September 2024
Resolved
The following functional requirements shall be met escape
routes shall be maintained in a safe condition, clear of
obstacles. Following stairwells have items obstructing
means of escape: 1) Crew stairwell; deck 09, MVZ 4, tables
are stored 2) Passenger stairwell, signs stored near spa on
deck 09. 3) Passenger stairwell, carts stored on deck 09,
MVZ 4. 4) Charis on deck 09 ivo Ledo deck restaurant.
74 SOLAS 20 II-2/13.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2024
Resolution: All obstruction removed from spaces.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 12 September 2024
Resolved
Fire protection systems and fire-fighting systems and
appliances shall be maintained ready for use. Fire hose
station (9.1.27) is secured shut with tie down line, not easily accessed if required.
74 SOLAS 20 II-2/14.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2024
Resolution: Line was removed from fire station door.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 September 2024
Resolved
A fixed fire-extinguishing system, required by this chapter
shall comply with the provisions of the Fire Safety Systems
Code. PSCO observed 04 failed high-fog sprinkler heads on
deck 8 & 9, in fire zone 06. Sprinkler heads (C10-57C70
1662, C10-57C/0 1662) failed to activate and discharge
water upon application of heat, via a heat gun, on ampules.
74 SOLAS 20 II-2/10.4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2024
Resolution: 5 nozzles in sprinkler section 42 and 5 nozzles in sprinkler section 48 now activated and discharge after application of heat, using heat gun. Actionable Item in vessel’s status AI-E-038 now closed satisfactory. Class report received.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 September 2024
Resolved
A fixed fire detection and fire alarm system and sample
extrication smoke detection system shall be of an approved
type and comply with the Fire Safety Systems Code. Any required fixed fire detection and fire alarm system with
manually activated call points shall be capable of immediate
operation at all times. PSC observed 02 inoperable smoke
detectors number 127-154 on deck 10 aft and 01 inoperable
call point outside room 10004.
74 SOLAS 20 II-2/7.2.4.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2024
Resolution: Smoke detectors and manual call point repaired and retested, sat.
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 12 September 2024
Resolved
Emergency escape breathing devices shall comply with the
Fire Safety Systems Code. Spare emergency escape
breathing devices shall be kept onboard. PSCO observed
an expired EEBD in Eengine Room, IVO FSD 0C.2.19.
74 SOLAS 20 II-2/13.3.4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2024
Resolution: EEBD replaced with serviceable EEBD.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 September 2024
Resolved
Waste receptacles shall be constructed of
non-combustible materials with no openings in the sides or
bottom. PSCO observed plastic garbage cans with general
combustible waste throughout the ship in galleys, pantries,
and in the garbage handling room- where ship's crews were
not actively sorting wastes. Per the ship's garbage
management plan, crews are permitted to use combustible
garbage cans in galleys, bars and pantries- this practice is in violation to the subject regulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 15 September 2024
Resolution: Combustible waste receptacles removed.
14 - Pollution Prevention › 145 - MARPOL Annex V › Other (MARPOL Annex V)
Issued 12 September 2024
Resolved
Every ship of 100gt or above and every ship that carries 15 or more persons….shall carry a garbage management plan that the crew shall follow. Placard to indicate how to dispose of
garbage is contradictory to Garbage Management plan.
Plan indicates all garbage shall be disposed of in
non-cobnustable recepticales, except for pantries, galleys
and bars.
ANNEX V / Reg 10.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 15 September 2024
Resolution: Incorrect placards removed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 September 2024
Resolved
Fire extinguishers shall be situated ready for use at easily
visible places, which can be reached quickly and easily at
any time in the event of a fire, and in such a way that their
serviceability is not impaired by the weather, vibration or
other external factors. Portable fire extinguishers shall be
provided with devices which indicate whether they have
been used. PSCO observed a fire extinguisher 10.6.03, in a
locker behind two doors in the crows nest lounge, without any
signage indicating fire extinguisher is located there.
74 SOLAS 20 II-2/10.3.2.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 12 September 2024
Resolution: IMO placard place outside the space to identify the fire extinguisher.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 September 2024
Resolved
The construction of doors and door frames in 'A" class
divisions, with the means of securing them when closed,
shall provide resistance to fire as well as to the passage of
smoke and flame equivalent to that of the bulkheads in which
the doors are situated. PSCO observed considerable
(aprox. 1"X1/4") gap in hose port on FSD 10.6.02.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 12 September 2024
Resolution: Vessel sealed the gap with plate.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 12 September 2024
Resolved
Any ship of 10,000 gross tonnage and above shall be fitted
with oil filtering equipment complying with paragraph 7 of
this regulation. Oil content meter on static oily water
separator, is activating the 3 way valve beyond the 15 ppm
threshold.
MARPOL 2017 Annex I / 14.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 15 September 2024
Resolution: Class conducted IOPP equipment tested satisfactory no time delay observed 3 way activated at 15ppm. Actionable Item in vessel’s status AI-E-039 now closed satisfactory
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 12 September 2024
Resolved
The machinery, boilers and other pressure vessels,
associated piping systems and fittings shall be of a design
and construction adequate for the service for which they are
intended and shall be so installed and protected as to reduce
to a minimum any danger to persons on board, due regard
being paid to moving parts, hot surfaces and other hazards.
Stbd steering gear fall prevention railing has crack at based
stanchion, considerably weakening rail holdback strength.
74 SOLAS 04 II-1/26.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 15 September 2024
Resolution: Stanchion repaired satisfactory by welding. Actionable Item in vessel’s status AI-E-039 now closed satisfactory. Class report issued.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 September 2024
Resolved
Fire hoses shall be of non-perishable material and shall be
sufficient in length to project a jet of water to any of the spaces in which they may be required to be used Each hose shall be provided with a nozzle and the necessary couplings. Fire hose station D.03.13 and D.04.09 were missing spanner
wrenches.
74 SOLAS 20 II-2/10.2.3.1.1
Action required: 10 - Deficiency Rectified
Resolved 12 September 2024
Resolution: Spanner wrenches place in fire hose stations.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 September 2024
Resolved
Where the contents and use of a space are such that there is adoubt as to its classification for the purpose of this regulation, or where it is possible to assign two or more classifications to a space, it shall be treated as a space within the relevant category having the most stringent boundary requirements. PSCO observed storage of combustible
material (solids annd liquids) in technical spaces IVO crew
cabin C001, C007, B003, C018, B120, B007, fire station
B.4.18, B.05.07, B. 04.04, fire extinguisher C.04.02, and in
AC space behind door 4.4.25.
74 SOLAS 20 II-2/9.2.2.3.2.2
Action required: 10 - Deficiency Rectified
Resolved 12 September 2024
Resolution: All combustible materials removed from technical spaces.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 September 2024
Resolved
Electrical installations shall be such that: the safety of
passengers, crew and ship from electrical hazards will be
ensured. PSCO observed a holdback device on an
electrical panel in garbage room near escape ffrom
machinery space.
74 SOLAS 04 II-1/40.1.3
Action required: 10 - Deficiency Rectified
Resolved 12 September 2024
Resolution: Hold back on electrical panel removed. Panel doors secured with square key latching device as designed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 October 2023
Resolved
Openings in "A" class divisions. Openings in bulkheads and decks in passenger ships. Fire Doors in main vertical zone bulkheads, galley boundaries and stairway enclosures other other than power-operated watertight doors and those which are normally locked shall satisfy the following requirements: a door re-open not more than 1 m from the point of contact. The vessel's FSD 02.4.41 damage to bottom hinge prevented door from closing. FSD 04.6.10 hit door jam at the bottom and did not close properly. The vessel's FSD 02.5.18 had a cracked doorframe and the timing prevented the door from closing properly.
74 SOLAS 01 II-2/30
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2023
Resolution: All doors fixed to the satisfaction of class.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 16 October 2023
Resolved
Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. Portable extinguishers which have been discharged shall be immediately recharged or replaced with an equivalent unit. Fire station cabinet missing access handle.
74 SOLAS 20 II-2/14.2.1.2
Action required: 10 - Deficiency Rectified
Due 16 October 2023
Resolved 16 October 2023
Resolution: Replaced handle.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 22 April 2023
Resolved
Every ship shall be provided with: subject to provisions of regulation 8.3, a satellite Emergency Position-Indicating Radio Beacon (EPIRB). EPIRB in free arrangement above bridge found with expired battery.
SOLAS 74(2020) IV/7.1.6
Action required: 10 - Deficiency Rectified
Due 22 April 2023
Resolved 22 April 2023
Resolution: The vessel had a spare additional EPIRB. Additionally, the vessel's Class was on board and was taking for action.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 April 2022
Resolved
In addition to the emergency lighting required by regulations II-I/42 and III/11.5, The means of escape, including stairways and exits shall be marked by lighting or photo luminescent strip indicators placed not more than 300 mm above the deck at all points of escape routing including angles and intersections. Electric low location lighting was extinguished in various locations throughout Deck 0 MVZ 5 to include the hospital and crew accommodation.
SOLAS 20 II-2/13.2.5.1
Action required: 10 - Deficiency Rectified
Resolved 21 April 2022
Resolution: Vessel identified and rectified electrical fault in lightning switchboard.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 April 2022
Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release... Quick release mechanisms shall be designed and installed to the satisfaction of the Administration and in particular: not be equipped with any locking device, set screw or other arrangement that prevents the release of the latch when pressure is applied to the releasing device... Escape route doors in Deck 10 "Club Hal" had installed twist locks without means for quick release.
Action required: 10 - Deficiency Rectified
Resolved 21 April 2022
Resolution: Vessel removed internal locking mechanism and replaced with blanks.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 April 2019
Resolved
The traditional wooden lining on the bulkheads and ceiling are permitted in sauna. the distance from the hot surfaces to combustible material shall be at least 500mm or the combustible materials shall be protected. There was no protection on combustible material and charring was present in mens sauna. Solas Ch II-2 Reg 2.2.3.4.3
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 29 April 2019
Resolved 29 April 2019
Resolution: Crew install alluminum strips to protect wood.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 29 April 2019
Resolved
Every crewmember with assigned emergency duties shall be familiar with these duties before the voyage begins. Port side life boat team was unfamiliar with the decending units for life boats. Solas Ch III Reg 19 2.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2019
Resolved 15 May 2019
Resolution: Receieved documentation that assigned personnel had completed additional flag-approved training on life saving launching arrangement.
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 29 April 2019
Resolved
In addition to the emergency lighting required..., the means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicaters placed not more than 300mm above the deck at all points of escape routes. Low location lighting or tape is missing from aft crew stairway deck A & B. Solas Ch II-2 Reg 13 3.2.5.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 29 April 2019
Resolved 29 April 2019
Resolution: Crew installed photoluminescent tape.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 29 April 2019
Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with structural, mechanical and electrical requirements of a Class/RO or with applicable national standards of the Administration which provide an equivalent level of safety. Identified a piece of floor tile raised and not flushed with the surrounding floor presenting a tripping hazard to passengers and crew. Floor tile is located on the starboard side deck one, at the entrance to the Vista Lounge. The crew placed a yellow cone in the area for passengers to avoid the tile until repairs are complete. Solas 2002 Ch. II Reg 3-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2019
Resolved 15 May 2019
Resolution: Tile flush.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 23 August 2018
Resolved
11112: Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The #5 lifeboat davit is not ready for immediate use. 74 SOLAS 14 CH. III 20.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2018
Resolved 20 September 2018
Resolution: Repairs certified by LR and witnessed sat lowering of LB#5 to boat deck.