← All vessels
SHARK 2
SHARK 2 is a passenger vessel (inspected). The Coast Guard has recorded 10 inspections since 2016, most recently in May 2025, along with 27 deficiencies and 1 operational control.
Records from 2016 to 2025. Most recent: inspection, 12 May 2025.
- Built
- Not recorded
- Last inspected
- 12 May 2025
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 27 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
Years with a record
10 calendar years (2016–2025)
The 10 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
10 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 10
12 May 2025
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8130272
13 May 2024
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7913248
15 May 2023
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7681277
4 May 2022
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7450043
27 April 2021
COI Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7179390
18 June 2020
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6986125
14 May 2019
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6675490
22 May 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6417096
25 May 2017
Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6160741
4 May 2016
DAPI Audit · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5873434
Deficiency record · 27
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 May 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Aspirin and burn gel were expired. 46 CFR 184.710
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 May 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead end wires were present under helm console.46 CFR 183.200(b)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 May 2025
Resolved
Cable and wire for power and lighting circuits must: (1)Meet Section 310-13 of NFPA 70 (incorporated by reference; see 46 CFR 175.600);(2) Be listed by Underwriters Laboratories (UL), as UL Boat or UL Marine cable; or(3) Meet § 111.60-1 in subchapter J of this chapter for cable, and § 111.60-11 in subchapter J of this chapter for wire. Speaker cable not rated for marine use was routed through center void. 46 CFR 183.340(d)
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 May 2025
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. 46 CFR 183.430
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 May 2022
Resolved
The owner or managing operator shall have ready for its inspection its hull structure or appurtenances. Vessels aft aluminum tube stanchion structure which supports initial inflation of parasail has three large cracks in different locations. Vessel shall submit repair plan and make repairs to the satisfaction of the OCMI.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 27 April 2021
Resolved
The minimum number of portable fire extinguishers required on a vessel must not be fewer than the minimum number required by 46 CFR Table 181.500(b). 10 B:C portable fire extinguisher discovered of the non-serviceable type. 46 CFR 181.500(b)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 27 April 2021
Resolved
A hatch exposed to the weather must be watertight except a hatch on a vessel that operates only on protected waters may be weathertight. Engine compartment hatch gasket discovered worn and partially removed. 46 CFR 179.360(a)(3)
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 April 2021
Resolved
The vessel will have mounted at the operating station, emergency instructions containing the actions be to taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions placard discovered severely faded. 46 CFR 185.510(a)
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 18 June 2020
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible vapors are present. Vessel requires vapor barrier in wire run from engine room to midship space.
46 CFR 177.405(e)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 June 2020
Resolved
Each life ring buoy on a vessel must be approved in accordance with 46 CFR 160.050. Vessel's life ring did not have any retroreflective tape.
46 CFR 180.70(b)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2019
Resolved
A vessel of more than 7.9 meters in length, but not more than 19.8 meters must carry a minimum of one life buoy of not less than 24 inches in diameter. Line on ring life buoy is worn and inadequate. 46CFR180.70(a)(2) code 16c
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 14 May 2019
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. 46CFR185.516(a) code 16c
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 14 May 2019
Resolved
The master or person in charge of a ship shall ensure that one or more placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so they can be read by the crew and passengers. Vessel is missing garbage management placard. 33CFR151.59 code 16c
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 May 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. No navigation chart was onboard. 46CFR184.420(a)(1) code 16c
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 May 2018
Resolved
Vessel has expired certificate of documentation. Provide proof of valid COD. 46CFR67.7
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 May 2017
Resolved
Vessel does not have a Coast Guard Light List onboard IAW 46 CFR 184.420.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 25 May 2017
Resolved
Vessel Does not have Inland Navigation Rules publication onboard IAW 46 CFR 184.420.
Navigation › Piloting/Steering › Marine Charts
Issued 25 May 2017
Resolved
Vessel does not have Marine Charts onboard for the local operating area IAW 46 CFR 184.420.
Navigation › Piloting/Steering › US Coast Pilot
Issued 25 May 2017
Resolved
Vessel does not have a US Coast Pilot publication onboard IAW 46 CFR 184.420.
Lifesaving › Lifebuoys › Stowage
Issued 25 May 2017
Resolved
Life Ring does not have 60 feet of appoved line attached to ring. Life light does not have 3 to 6 feet of line with corrosion resistant clip attached around body of life ring. 46 CFR 180.70.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 May 2017
Resolved
U-Joint and shaft coming from Main Diesel Engine does not have a guard protecting it. Winch for bringing parasailers in does not have a chain guard over it. 46 CFR 177.960
Documentation › Certificates/Documents › Stability Letter
Issued 25 May 2017
Resolved
Stability Letter is not on board vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 May 2017
Resolved
Vessel has radio amplifier installation installed without plan approval. Amplifier and associated wires need to be removed. 46 CFR 176.700.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 May 2017
Resolved
Vessel has exposed wire not connected to anything in the engine compartment hanging on the starboard side of the aft bulkhead. Wire needs to be removed. 46 CFR 183.200
Construction/Loadline › Penetrations › Gasket
Issued 25 May 2017
Resolved
Battery Space Gasket and Engine Room Gasket is not sealing weathertight hatch. Gasket Needs Replacement. 46 CFR 179.360
Construction/Loadline › Structures › Scupper
Issued 4 May 2016
Resolved
Forward compartment watertight hatch scupper drain line not attached.
Engineering › Bilge Water Management System › Interface Detector
Issued 4 May 2016
Resolved
High Level Bilge Alarms not labeled at operators station
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.