MAURY USCG vessel records
← All vessels

SHARK 2

SHARK 2 is a passenger vessel (inspected). The Coast Guard has recorded 10 inspections since 2016, most recently in May 2025, along with 27 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 12 May 2025.

Built
Not recorded
Last inspected
12 May 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

805413
Flag
UNITED STATES
Maury page id
psix-805413

Inspections, by type

Years with a record 10 calendar years (2016–2025)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 10

12 May 2025 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8130272
13 May 2024 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7913248
15 May 2023 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7681277
4 May 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7450043
27 April 2021 COI Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7179390
18 June 2020 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6986125
14 May 2019 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6675490
22 May 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6417096
25 May 2017 Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6160741
4 May 2016 DAPI Audit · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5873434

Deficiency record · 27

09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 May 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Aspirin and burn gel were expired. 46 CFR 184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 14 May 2025
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead end wires were present under helm console.46 CFR 183.200(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 14 May 2025
Resolution: MI attended vessel verifying dead end wires properly terminated.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 May 2025 Resolved
Cable and wire for power and lighting circuits must: (1)Meet Section 310-13 of NFPA 70 (incorporated by reference; see 46 CFR 175.600);(2) Be listed by Underwriters Laboratories (UL), as UL Boat or UL Marine cable; or(3) Meet § 111.60-1 in subchapter J of this chapter for cable, and § 111.60-11 in subchapter J of this chapter for wire. Speaker cable not rated for marine use was routed through center void. 46 CFR 183.340(d)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 14 May 2025
Resolution: MI attended vessel verifying all non-compliant wiring removed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 May 2025 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. 46 CFR 183.430
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 14 May 2025
Resolution: MI attended vessel verifying portable lights were placed onboard.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 May 2022 Resolved
The owner or managing operator shall have ready for its inspection its hull structure or appurtenances. Vessels aft aluminum tube stanchion structure which supports initial inflation of parasail has three large cracks in different locations. Vessel shall submit repair plan and make repairs to the satisfaction of the OCMI.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 14 June 2022
Resolution: Received pictures of crack repairs. All SAT.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 27 April 2021 Resolved
The minimum number of portable fire extinguishers required on a vessel must not be fewer than the minimum number required by 46 CFR Table 181.500(b). 10 B:C portable fire extinguisher discovered of the non-serviceable type. 46 CFR 181.500(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2021
Resolution: MI team verified replacement portable fire extinguisher of the serviceable type.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 27 April 2021 Resolved
A hatch exposed to the weather must be watertight except a hatch on a vessel that operates only on protected waters may be weathertight. Engine compartment hatch gasket discovered worn and partially removed. 46 CFR 179.360(a)(3)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2021
Resolution: MI team verified updated hatch gasket to make engine compartment hatch weathertight.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 April 2021 Resolved
The vessel will have mounted at the operating station, emergency instructions containing the actions be to taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions placard discovered severely faded. 46 CFR 185.510(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 30 April 2021
Resolution: MI team verified updated emergency instruction sticker.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 18 June 2020 Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible vapors are present. Vessel requires vapor barrier in wire run from engine room to midship space. 46 CFR 177.405(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2020
Resolved 30 September 2020
Resolution: Received photo of proper installation of vapor barrier in wire run from engine room to midship space.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 June 2020 Resolved
Each life ring buoy on a vessel must be approved in accordance with 46 CFR 160.050. Vessel's life ring did not have any retroreflective tape. 46 CFR 180.70(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2020
Resolved 30 September 2020
Resolution: Received satisfactory report of life ring retroreflective tape being repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2019 Resolved
A vessel of more than 7.9 meters in length, but not more than 19.8 meters must carry a minimum of one life buoy of not less than 24 inches in diameter. Line on ring life buoy is worn and inadequate. 46CFR180.70(a)(2) code 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2019
Resolved 17 May 2019
Resolution: New life ring has been labeled and installed.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 14 May 2019 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. 46CFR185.516(a) code 16c
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 15 May 2019
Resolution: New placard has been installed and is visible to passengers.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 14 May 2019 Resolved
The master or person in charge of a ship shall ensure that one or more placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so they can be read by the crew and passengers. Vessel is missing garbage management placard. 33CFR151.59 code 16c
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 15 May 2019
Resolution: New placard has been installed and is visible to passengers.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 May 2019 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. No navigation chart was onboard. 46CFR184.420(a)(1) code 16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 15 May 2019
Resolution: Chart has been placed onboard.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 May 2018 Resolved
Vessel has expired certificate of documentation. Provide proof of valid COD. 46CFR67.7
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2018
Resolution: Received confirmation from NVDC that COD had been processed.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 May 2017 Resolved
Vessel does not have a Coast Guard Light List onboard IAW 46 CFR 184.420.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 6 June 2017
Resolution: Provided Light List.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 25 May 2017 Resolved
Vessel Does not have Inland Navigation Rules publication onboard IAW 46 CFR 184.420.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 25 May 2017
Resolution: Vessel is outfitted with a copy of Navigation Rules.
Navigation › Piloting/Steering › Marine Charts
Issued 25 May 2017 Resolved
Vessel does not have Marine Charts onboard for the local operating area IAW 46 CFR 184.420.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 6 June 2017
Resolution: Provided Charts.
Navigation › Piloting/Steering › US Coast Pilot
Issued 25 May 2017 Resolved
Vessel does not have a US Coast Pilot publication onboard IAW 46 CFR 184.420.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 6 June 2017
Resolution: Provided Coast Pilot.
Lifesaving › Lifebuoys › Stowage
Issued 25 May 2017 Resolved
Life Ring does not have 60 feet of appoved line attached to ring. Life light does not have 3 to 6 feet of line with corrosion resistant clip attached around body of life ring. 46 CFR 180.70.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 6 June 2017
Resolution: Life Ring, Float Light, and life line are correctly configured and installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 May 2017 Resolved
U-Joint and shaft coming from Main Diesel Engine does not have a guard protecting it. Winch for bringing parasailers in does not have a chain guard over it. 46 CFR 177.960
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 6 June 2017
Resolution: Guards were provided for exposed hazards.
Documentation › Certificates/Documents › Stability Letter
Issued 25 May 2017 Resolved
Stability Letter is not on board vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 6 June 2017
Resolution: Stability Letter provided onboard vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 May 2017 Resolved
Vessel has radio amplifier installation installed without plan approval. Amplifier and associated wires need to be removed. 46 CFR 176.700.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 6 June 2017
Resolution: Amplifier Installation was removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 May 2017 Resolved
Vessel has exposed wire not connected to anything in the engine compartment hanging on the starboard side of the aft bulkhead. Wire needs to be removed. 46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 6 June 2017
Resolution: Wire was disconnected, capped off and heat shrank.
Construction/Loadline › Penetrations › Gasket
Issued 25 May 2017 Resolved
Battery Space Gasket and Engine Room Gasket is not sealing weathertight hatch. Gasket Needs Replacement. 46 CFR 179.360
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 6 June 2017
Resolution: Gaskets were replaced.
Construction/Loadline › Structures › Scupper
Issued 4 May 2016 Resolved
Forward compartment watertight hatch scupper drain line not attached.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 4 May 2016
Resolution: Reattached Forward compartment watertight hatch scupper drain line with threaded tube and adhesive.
Engineering › Bilge Water Management System › Interface Detector
Issued 4 May 2016 Resolved
High Level Bilge Alarms not labeled at operators station
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 4 May 2016
Resolution: Operator labeld high level alarms at operators station

Ownership record