MAURY USCG vessel records Sign in
← All vessels

SHARK 2

SHARK 2 is a passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2006, most recently in May 2025, along with 46 deficiencies and 1 operational control.

Records from 2006 to 2025. Most recent: inspection, 12 May 2025.

Built
Not recorded
Last inspected
12 May 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

805413
Flag
UNITED STATES
—
Maury page id
psix-805413

Inspections, by type

…with no type recorded1
Years with a record 15 calendar years (2006–2025)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

12 May 2025 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8130272
13 May 2024 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7913248
15 May 2023 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7681277
4 May 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7450043
27 April 2021 COI Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7179390
18 June 2020 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6986125
14 May 2019 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6675490
22 May 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6417096
25 May 2017 Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6160741
4 May 2016 DAPI Audit · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5873434
14 May 2012 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4311120
14 April 2009 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3450218
21 June 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3248564
30 May 2007 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2981046
7 June 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2673116
11 May 2006 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2650468
1 February 2006 Hull Examination · COI Inspection · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2577510

Deficiency record · 46

09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 May 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Aspirin and burn gel were expired. 46 CFR 184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 14 May 2025
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead end wires were present under helm console.46 CFR 183.200(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 14 May 2025
Resolution: MI attended vessel verifying dead end wires properly terminated.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 May 2025 Resolved
Cable and wire for power and lighting circuits must: (1)Meet Section 310-13 of NFPA 70 (incorporated by reference; see 46 CFR 175.600);(2) Be listed by Underwriters Laboratories (UL), as UL Boat or UL Marine cable; or(3) Meet § 111.60-1 in subchapter J of this chapter for cable, and § 111.60-11 in subchapter J of this chapter for wire. Speaker cable not rated for marine use was routed through center void. 46 CFR 183.340(d)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 14 May 2025
Resolution: MI attended vessel verifying all non-compliant wiring removed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 May 2025 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. 46 CFR 183.430
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 14 May 2025
Resolution: MI attended vessel verifying portable lights were placed onboard.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 May 2022 Resolved
The owner or managing operator shall have ready for its inspection its hull structure or appurtenances. Vessels aft aluminum tube stanchion structure which supports initial inflation of parasail has three large cracks in different locations. Vessel shall submit repair plan and make repairs to the satisfaction of the OCMI.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 14 June 2022
Resolution: Received pictures of crack repairs. All SAT.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 27 April 2021 Resolved
The minimum number of portable fire extinguishers required on a vessel must not be fewer than the minimum number required by 46 CFR Table 181.500(b). 10 B:C portable fire extinguisher discovered of the non-serviceable type. 46 CFR 181.500(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2021
Resolution: MI team verified replacement portable fire extinguisher of the serviceable type.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 27 April 2021 Resolved
A hatch exposed to the weather must be watertight except a hatch on a vessel that operates only on protected waters may be weathertight. Engine compartment hatch gasket discovered worn and partially removed. 46 CFR 179.360(a)(3)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2021
Resolution: MI team verified updated hatch gasket to make engine compartment hatch weathertight.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 April 2021 Resolved
The vessel will have mounted at the operating station, emergency instructions containing the actions be to taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions placard discovered severely faded. 46 CFR 185.510(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 30 April 2021
Resolution: MI team verified updated emergency instruction sticker.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 18 June 2020 Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible vapors are present. Vessel requires vapor barrier in wire run from engine room to midship space. 46 CFR 177.405(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2020
Resolved 30 September 2020
Resolution: Received photo of proper installation of vapor barrier in wire run from engine room to midship space.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 June 2020 Resolved
Each life ring buoy on a vessel must be approved in accordance with 46 CFR 160.050. Vessel's life ring did not have any retroreflective tape. 46 CFR 180.70(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2020
Resolved 30 September 2020
Resolution: Received satisfactory report of life ring retroreflective tape being repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2019 Resolved
A vessel of more than 7.9 meters in length, but not more than 19.8 meters must carry a minimum of one life buoy of not less than 24 inches in diameter. Line on ring life buoy is worn and inadequate. 46CFR180.70(a)(2) code 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2019
Resolved 17 May 2019
Resolution: New life ring has been labeled and installed.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 14 May 2019 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. 46CFR185.516(a) code 16c
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 15 May 2019
Resolution: New placard has been installed and is visible to passengers.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 14 May 2019 Resolved
The master or person in charge of a ship shall ensure that one or more placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so they can be read by the crew and passengers. Vessel is missing garbage management placard. 33CFR151.59 code 16c
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 15 May 2019
Resolution: New placard has been installed and is visible to passengers.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 May 2019 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. No navigation chart was onboard. 46CFR184.420(a)(1) code 16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 15 May 2019
Resolution: Chart has been placed onboard.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 May 2018 Resolved
Vessel has expired certificate of documentation. Provide proof of valid COD. 46CFR67.7
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2018
Resolution: Received confirmation from NVDC that COD had been processed.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 May 2017 Resolved
Vessel does not have a Coast Guard Light List onboard IAW 46 CFR 184.420.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 6 June 2017
Resolution: Provided Light List.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 25 May 2017 Resolved
Vessel Does not have Inland Navigation Rules publication onboard IAW 46 CFR 184.420.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 25 May 2017
Resolution: Vessel is outfitted with a copy of Navigation Rules.
Navigation › Piloting/Steering › Marine Charts
Issued 25 May 2017 Resolved
Vessel does not have Marine Charts onboard for the local operating area IAW 46 CFR 184.420.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 6 June 2017
Resolution: Provided Charts.
Navigation › Piloting/Steering › US Coast Pilot
Issued 25 May 2017 Resolved
Vessel does not have a US Coast Pilot publication onboard IAW 46 CFR 184.420.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 6 June 2017
Resolution: Provided Coast Pilot.
Lifesaving › Lifebuoys › Stowage
Issued 25 May 2017 Resolved
Life Ring does not have 60 feet of appoved line attached to ring. Life light does not have 3 to 6 feet of line with corrosion resistant clip attached around body of life ring. 46 CFR 180.70.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 6 June 2017
Resolution: Life Ring, Float Light, and life line are correctly configured and installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 May 2017 Resolved
U-Joint and shaft coming from Main Diesel Engine does not have a guard protecting it. Winch for bringing parasailers in does not have a chain guard over it. 46 CFR 177.960
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 6 June 2017
Resolution: Guards were provided for exposed hazards.
Documentation › Certificates/Documents › Stability Letter
Issued 25 May 2017 Resolved
Stability Letter is not on board vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 6 June 2017
Resolution: Stability Letter provided onboard vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 May 2017 Resolved
Vessel has radio amplifier installation installed without plan approval. Amplifier and associated wires need to be removed. 46 CFR 176.700.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 6 June 2017
Resolution: Amplifier Installation was removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 May 2017 Resolved
Vessel has exposed wire not connected to anything in the engine compartment hanging on the starboard side of the aft bulkhead. Wire needs to be removed. 46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 6 June 2017
Resolution: Wire was disconnected, capped off and heat shrank.
Construction/Loadline › Penetrations › Gasket
Issued 25 May 2017 Resolved
Battery Space Gasket and Engine Room Gasket is not sealing weathertight hatch. Gasket Needs Replacement. 46 CFR 179.360
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2017
Resolved 6 June 2017
Resolution: Gaskets were replaced.
Construction/Loadline › Structures › Scupper
Issued 4 May 2016 Resolved
Forward compartment watertight hatch scupper drain line not attached.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 4 May 2016
Resolution: Reattached Forward compartment watertight hatch scupper drain line with threaded tube and adhesive.
Engineering › Bilge Water Management System › Interface Detector
Issued 4 May 2016 Resolved
High Level Bilge Alarms not labeled at operators station
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 4 May 2016
Resolution: Operator labeld high level alarms at operators station
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 May 2012 Resolved
Provide proper support to the newly added raido wiring in void 2 using metalic wire supports every 24".
Due 15 June 2012
Resolved 16 July 2014
Resolution: Supports for radio wiring were approved and verified by attending Marine Inspector.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 14 May 2012 Resolved
Provide stowage marking for adult and child lifejackts.
Due 18 May 2012
Resolved 16 July 2014
Resolution: Proper markings were provided for adult and child lifejackets, verified by attending Marine Inspector.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 14 May 2012 Resolved
Provide logs for crew training, required fire and safety drills, and required lifesaving appliance inspections.
Due 15 June 2012
Resolved 14 July 2014
Resolution: Crew training and drill logs were up to date and onboard, verified by attending Marine Inspector
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 May 2012 Resolved
Provide aspirin and eye dressings for the vessels first aid kit.
Due 15 June 2012
Resolved 16 July 2014
Resolution: Aspirin and eye dressing was present in the medical kit. Verified by attending Marine Inspector.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 May 2012 Resolved
Provide identifying label for bilge high water alarms.
Due 15 June 2012
Resolved 8 August 2014
Resolution: Cleared based on subsequent successful inspection.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 May 2006 Resolved
Provide guards for main diesel engine belts, pulleys, and shaft.
Due 11 June 2006
Resolved 7 June 2006
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 11 May 2006 Resolved
Provide proof of original Certificate of Documentation prior to operating with passengers for hire. Copy of document can be faxed to [phone withheld].
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2006
Resolved 7 June 2006
Documentation › Certificates/Documents › FCC SSL
Issued 1 February 2006 Resolved
Provide FCC documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2006
Resolved 11 May 2006
Resolution: Not required for Lake Tahoe.
Navigation › Piloting/Steering › Marine Charts
Issued 1 February 2006 Resolved
Provide navigation publications.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2006
Resolved 11 May 2006
Lifesaving › Hand Flares › Not on Board
Issued 1 February 2006 Resolved
Provide flares & Horn.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2006
Resolved 11 May 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 February 2006 Resolved
Conduct drills & u/w test of machinery.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2006
Resolved 11 May 2006
Communications › Radio Communications › EPIRB
Issued 1 February 2006 Resolved
Provide EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2006
Resolved 11 May 2006
Resolution: Not required for route.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 1 February 2006 Resolved
Provide anchor & mooring lines.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2006
Resolved 11 May 2006
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 1 February 2006 Resolved
Provide PFD's & Life Ring w/ light.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2006
Resolved 7 June 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 February 2006 Resolved
Provide first aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2006
Resolved 11 May 2006
Fire Fighting › Fire Bucket › Availability
Issued 1 February 2006 Resolved
Provide fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2006
Resolved 11 May 2006
Engineering › Bilge Water Management System › Pump
Issued 1 February 2006 Resolved
Provide portable bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2006
Resolved 7 June 2006
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 1 February 2006 Resolved
Provide portable lighting.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2006
Resolved 11 May 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 February 2006 Resolved
Conduct new to zone inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2006
Resolved 11 May 2006

Ownership record