Records from 2008 to 2009. Most recent: inspection, 30 January 2009.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 13 March 2008
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 March 2008
Resolved 13 March 2008
Construction/Loadline › Penetrations › Pipe Flange
Issued 3 January 2008
Resolved
Replace cracked side shell thru hull fitting on Stbd side fourth one aft.
Action required: 705 - Other - as specified
Resolved 3 January 2008
Resolution: Replaced cracked side shell thru hull fitting on Stbd side fourth one aft.
Construction/Loadline › Structures › Deck Plating
Issued 3 January 2008
Resolved
Make main deck water tight in vicinity of bow pulpit.
Action required: 705 - Other - as specified
Resolved 3 January 2008
Resolution: Made main deck water tight in vicinity of bow pulpit.
Construction/Loadline › Structures › Scuttle
Issued 3 January 2008
Resolved
Gouge and re-weld fractured welds near hinge on forward hatch.
Action required: 705 - Other - as specified
Resolved 13 March 2008
Construction/Loadline › Structures › Scuttle
Issued 3 January 2008
Resolved
Replace broken dog on third hatch aft on main deck.
Action required: 705 - Other - as specified
Resolved 13 March 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 3 January 2008
Resolved
Repair loose life line stanchion located port side fourth one aft.
Action required: 705 - Other - as specified
Resolved 3 January 2008
Resolution: Repaired loose life line stanchion located port side fourth one aft.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 3 January 2008
Resolved
Repair loose compass / hand grab bracket at Stbd helm station.
Action required: 705 - Other - as specified
Resolved 3 January 2008
Resolution: Repaired loose compass / hand grab bracket at Stbd helm station.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 3 January 2008
Resolved
Gouge and weld fractured weld on compass / hand grab bracket port helm station.
Action required: 705 - Other - as specified
Resolved 3 January 2008
Resolution: Made proper repairs to compass / hand grab bracket port helm station.
Construction/Loadline › Structures › Scuttle
Issued 3 January 2008
Resolved
Gouge and weld fractured welds at hinge on main deck aft hinge.
Action required: 705 - Other - as specified
Resolved 13 March 2008
Engineering › Fuel Oil Service System › Filter
Issued 3 January 2008
Resolved
Install metal bowl under Racor filter.
Action required: 705 - Other - as specified
Resolved 13 March 2008
Electrical › Electrical Distribution System (service) › Junction Box
Issued 3 January 2008
Resolved
Install junction box cover in center head.
Action required: 705 - Other - as specified
Resolved 3 January 2008
Resolution: Installed junction box cover in center head.
Construction/Loadline › Structures › Superstructure
Issued 3 January 2008
Resolved
Re-install missing 1.5 " engine alarm repeater at operating station center.
Action required: 705 - Other - as specified
Resolved 13 March 2008
Accommodation/Occupational Safety › Potable Water System › General
Issued 3 January 2008
Resolved
Replace broken hold down strap on hot water heater.
Action required: 705 - Other - as specified
Resolved 3 January 2008
Resolution: Replaced broken hold down strap on hot water heater.
Construction/Loadline › Structures › Deck Plating
Issued 3 January 2008
Resolved
Make proper repairs to Stbd Life Raft inboard bracket.
Action required: 705 - Other - as specified
Resolved 13 March 2008
Construction/Loadline › Hull › Hull Plating
Issued 3 January 2008
Resolved
Make proper repairs to stern chine fiberglass cracks as marked.
Action required: 705 - Other - as specified
Resolved 13 March 2008