MANHATTAN

MANHATTAN is a 2006 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 2005, most recently in March 2026, along with 31 deficiencies and 1 operational control.

Records from 2005 to 2026. Most recent: inspection, 30 March 2026.

Built
2006
Last inspected
30 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD8872
806082
Flag
UNITED STATES
367303910
Maury page id
psix-806082

Inspections, by type

…with no type recorded2
Years with a record 18 calendar years (2005–2026)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)77.2 ft × 16.0 ft × 8.3 ft
Registered tonnagegross 68 / net 54
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSCARANO BOAT BUILDING INC · ALBANY, NY, UNITED STATES · built 2006
Hull materialAluminum
PropulsionDiesel Direct
Hull shapeShip
Hull configurationMonohull
Hailing portNEWPORT, RI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it31 - Displacement, Gross Ton
68 - Simplified, Gross Ton
54 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD8872MMSI 367303910 · active · compulsorily equipped · granted 19 July 2017, expires 19 July 2027
WDC9002MMSI 367096260 · expired · compulsorily equipped · granted 2 March 2006, cancelled 7 May 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 34

30 March 2026 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8332855
7 January 2026 Drydock Extension · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8291367
9 June 2025 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8155398
15 May 2024 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7912672
10 January 2024 Internal Structural Exam · Plan Review "T" Boat · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7847136
25 August 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7776379
17 May 2023 Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7685360
11 May 2022 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7449209
11 January 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7453953
17 September 2021 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7316232
8 April 2021 COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7171505
13 July 2020 Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7005966
10 March 2020 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6921320
10 March 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6925664
10 July 2019 Administrative Inspection · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6744891
7 November 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6576343
28 June 2018 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6456907
13 April 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6450560
3 January 2018 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6332034
8 December 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6321209
7 December 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6322884
19 June 2017 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6180080
20 July 2016 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5962191
14 April 2016 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5853930
15 March 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5838156
10 March 2014 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4813024
26 January 2011 Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3934809
29 March 2010 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3811941
28 June 2008 Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3250247
21 May 2008 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3224893
31 March 2008 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3174623
27 June 2007 MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2976609
16 May 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2650509
1 September 2005 Construction Oversight · COI Inspection · MARPOL Annex V Examination · Hull Examination · Plan Review "T" Boat · Inclining Experiment
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2481026

Deficiency record · 31

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 June 2025 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Fuel valves on port and starboard tank did not have remote shutoff means. 46 CFR 182.455(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2025
Resolved 20 June 2025
Resolution: Provided photo evidence of installed cables to remote fuel shutoffs. All sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 9 June 2025 Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. MI observed leak on the fire pump discharge elbow and 40 psi at the discharge gauge. 46 CFR 181.300(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2025
Resolved 20 June 2025
Resolution: Provided video evidence of pump making 60 PSI w/ no leaks at elbow. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 June 2025 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Fuel valves on port and starboard tank did not have remote shutoff means. MI observed port engine supply fuel valve seized.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2025
Resolved 20 June 2025
Resolution: Provided photo evidence of installed cables to remote fuel shutoffs. Verified operation with operator. All sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 June 2025 Resolved
Certification or licensing by a state or local jurisdiction as a fire extinguisher servicing agency will be accepted by the Coast Guard as meeting the personnel certification requirements of NFPA 10 for annual maintenance and recharging of extinguishers. Galley fwd portable extinguisher exceeded 12 months inspection date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2025
Resolved 20 June 2025
Resolution: Operator provided photo of new extinguisher and valid servicing tag. All sat.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 9 June 2025 Resolved
Vapor barriers. Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. Centerline exhaust piping penetration in aft bulkhead not vapor tight. 46 CFR 177.405(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2025
Resolved 20 June 2025
Resolution: Operator provided photo evidence of sealant around exhaust. Space is sufficiently vapor-tight at this location. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 June 2025 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). MI observed port life buoy missing retroreflective materiel. 46 CFR 185.604(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2025
Resolved 20 June 2025
Resolution: Operator provided photo evidence of new buoy.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 9 June 2025 Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. MI observed magnetic compass light inoperable. 46 CFR 184.402(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2025
Resolved 20 June 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 June 2025 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. MI observed anchor light as inoperable. 46 CFR 183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2025
Resolved 20 June 2025
Resolution: Operator provided photo evidence of anchor light illuminated. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 June 2025 Resolved
Pipes used for wet exhaust lines must be Schedule 80 or corrosion-resistant material and adequately protected from mechanical damage. MI observed port exhaust piping chaffing on deck longitudinal. 46 CFR 182.430(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2025
Resolved 20 June 2025
Resolution: Recieved photo evidence of channel trimmed back w/ rubber chafe pad installed. All Sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 May 2024 Resolved
Vessel Charts were not up-to-date. 46 CFR 184.420 "As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible"
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 26 May 2024
Resolution: Vessel representative provided proof of purchase of navgational charts. Photo is located under documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2024 Resolved
Provide techinical specification sheet for air compressor to MI for review. Air compressor for ship's horn needs ASME approval. 46 CFR 54.10-20 Pressure vessels (replaces UG-116, except paragraph (k), and UG-118). Pressure vessels that are required by § 54.10-3 to be stamped with the Coast Guard Symbol must also be stamped with the following information: (1) Manufacturer's name and serial number. (2) Coast Guard number, see § 50.10-30 of this subchapter. (3) Coast Guard Symbol, which is affixed only by the marine inspector. (4) Maximum allowable working pressure ____ kPa (____ psig) at ____ °C (____ °F). (5) Class. (6) Minimum design metal temperature, if below -18 °C (0 °F). (7) Water capacity in liters (U.S. gallons), if a cargo carrying pressure vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 26 May 2024
Resolution: Vessel's representative provided photo of techinical specification sheet for air compressor as well as photo of ASME stamp on air compressor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 15 May 2024 Resolved
Pipe installation on a/c lines needs to be renewed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 26 May 2024
Resolution: Pipe installation on a/c line were renewed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 July 2019 Resolved
A space containing propulsion machinery must have a fixed gas fire extinguishing system. Pre-engineered system was accidentally discharged during inspection. system must be serviced prior to carriage of pax. 46 CFR 181.400 Vessel has been authorized to carry passengers for one charter on 10 July. Vessel will provide 2 additional 40-BC fire extinguishers and 01 additional deckhand dedicated to engine room fire watch during this voyage. Upon completion of this charter, vessel is prohibited from carrying passengers until Pre-Engineered Fire Fighting system is recharged to the satisfaction of the Coast Guard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2019
Resolution: FF System restored/fully opertaional.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 July 2019 Resolved
A vessel must carry adaquate and up to date charts. Charts on board are dated 2017.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2019
Resolved 23 July 2019
Resolution: pics received.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 July 2019 Resolved
A vessel must carry a first aid kit approved under 160.041. First aid kit did contain ammonia inhalants. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2019
Resolved 23 July 2019
Resolution: pics received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 July 2019 Resolved
Each ring life buoy on a vessel must be approved IAW 160.050. Buoy with light is no longer servicable. Additionally, grab lines and light lanyard are not properly arranged. 46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2019
Resolved 23 July 2019
Resolution: pics received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 July 2019 Resolved
Each ring life buoy on a vessel must be marked with type II retroreflective material approved IAW 164.018 and as specified by IMO resolution A.658(16).02. Outboard ring buoys lacked 3/4 of required retroreflective material. 46 CFR 185.604(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2019
Resolved 23 July 2019
Resolution: pics received.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 7 November 2018 Resolved
Vsl is not broadcasting dimension information (AIS Antenna Position ABCD values equals 0) and Vsl is not broadcasting static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 10 March 2020
Resolution: Verified that AIS static data was programmed. See attached photos.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 June 2017 Resolved
Provide eye wash, aspirin, and iodine applicators for first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 30 June 2017
Resolution: Attened vessel, defs cleared.
Engineering › Bilge Water Management System › Pump
Issued 19 June 2017 Resolved
Prove proper operation at 50 GPM of bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 30 June 2017
Resolution: Attened vessel, defs cleared.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 28 June 2008 Resolved
Repair port main diesel engine to satisfaction of USCG marine Inspector and provide faxed copy said tech report to USCG.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 July 2008
Resolved 4 July 2008
Documentation › Certificates/Documents › FCC SSL
Issued 27 June 2007 Resolved
Obtain current FCC Safety Radio Certificate. Vessel operation restricted to no more than 1000 feet from shore until this requirement is met.
Action required: 705 - Other - as specified
Due 27 July 2007
Resolved 7 August 2007
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 1 September 2005 Resolved
Verify DC plan when they get it back from MSC.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 1 June 2006
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 1 September 2005 Resolved
Managing owner needs to be ADIRONDACK SAILING EXCURSIONS, LLC
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2006
Resolved 6 April 2006
Operations/Management › Drills/Instruction › Fire
Issued 1 September 2005 Resolved
Manifold for bilge and fire system is complex, a plan / signage must be created to help crewmembers operate bilge and fire systems.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2006
Resolved 6 April 2006
Navigation › Piloting/Steering › Marine Charts
Issued 1 September 2005 Resolved
Provide charts.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2006
Resolved 6 April 2006
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 1 September 2005 Resolved
Provide contract for ADIRONDACK SAILING EXCURSIONS, LLC
Action required: 705 - Other - as specified
Due 6 April 2006
Resolved 6 April 2006
Documentation › Logs/Records › Logbook (official)
Issued 1 September 2005 Resolved
Provide official logbook.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2006
Resolved 6 April 2006
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 1 September 2005 Resolved
Provide at least 10 more adult lifejackets
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 April 2006
Resolved 6 April 2006
Documentation › Markings/Placards › Warning Signs
Issued 1 September 2005 Resolved
Add "KEEP CLEAR" to emergency escape signage and locate in highly visIble location.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2006
Resolved 6 April 2006
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 1 September 2005 Resolved
Provide 2 portable lights designated as Emergency Lights.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2006
Resolved 6 April 2006

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.