Records from 2006 to 2022. Most recent: inspection, 5 October 2022.
Inspection history · 18
5 October 2022
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7571678
5 October 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7572400
31 January 2022
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7386002
27 September 2021
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7320637
18 September 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7314974
29 November 2019
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6864537
18 September 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6814811
17 September 2019
ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6808694
16 July 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6751983
26 February 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5822609
26 July 2009
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3540447
8 July 2008
ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3261093
15 February 2007
NPV Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2872582
3 September 2006
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2767427
3 May 2006
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2639378
20 February 2006
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2588573
17 February 2006
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2587627
17 February 2006
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2587649
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management Plan (BWMP)
Issued 5 October 2022
Resolved
A vessel equipped with ballast water tanks that operates in the waters of the United States must maintain a ballast water management plan that has been
developed specifically for the vessel and that will allow those responsible for the plans implementation to understand and follow the vessel's ballast water
management strategy and comply with the requirements of this subpart.
Vessel’s ballast water management plan does not include all of the necessary provisions listed in 33CFR 151 Subpart D.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2022
Resolved 12 October 2022
Resolution: Vessel provide addendum to the BWMP which includes U.S. ballast water regulations and requirements as per 33 CFR 151.2000.
Construction/Loadline › Markings › Load Line Mark
Issued 17 February 2006
Resolved
Deck line is not painted in contrasting color to back ground. ICLL 1966 Annex 1 Chap 1 Reg8 Rectify to the satisfaction of class first US port after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 May 2006
Resolved 5 May 2006
Resolution: Sector LA/LB cleared.