11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 14 November 2021
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in a working order and ready for immediate use.
PSCO observed that rescue boast did not maintain idle upon start and secures without crew. Rescue boat is not ready for immediate use. (74SOLAS(14)III/20.2); 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2021
Resolution: Vessel provided Flag Society report stating the failure was caused by the inlet of the carburetor was not clean and the engine of rescue boat can’t running stable. The crews opened and clean the carburetor and the rescue boat is now fully operable.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 5 May 2016
Resolved
0715-Detection. Heat detector failed to alarm during testing and heat source used from testing emittied such a high temperature that the detector head melted. PSCO review of SMS testing requirments determined that there are no procedures for testing the heat detector and not logged maintenance of it every being completed. SOLAS IX/3.1...ISM REG 7.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 May 2016
Resolved 7 May 2016
Resolution: Recieved a Bureau Veritas Class Report stating that the deficiency was corrected.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 5 May 2016
Resolved
0750-Fire Prevention.PSCO observed four (4) 55 Gallon drums of sludge being stored near the incenirator obove the Ships Service Generators. SOLAS II-2/4.2.2.3.3
Action required: 17 - Rectify deficiencies prior to departure
Due 5 May 2016
Resolved 7 May 2016
Resolution: Recieved a Bureau Veritas Class Report stating that the deficiency was corrected.
Construction/Loadline › Structures › Door
Issued 5 May 2016
Resolved
0910-Closing devices watertight doors.WTD leading from Engineroom to Steering compartment is equipped with a indicating switch that is visible on the Bridge and locally. PSCO's osbserved a string by-passing the indicating device to give a false signal to the bridge that the door was close, when in fact it was not. SOLAS II-1/13-1.
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 7 May 2016
Resolution: Recieved a Bureau Veritas Class Report stating that the deficiency was corrected.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 5 May 2016
Resolved
1410-Propulsion Main Engine. Drain valve for the fuel oil leak tank was left in the open postion by-passing the requirement to provide an alarm in the event of a high pressure fuel line failure. SOLAS II-2/4.2.2.5.2
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 7 May 2016
Resolution: Recieved a Bureau Veritas Class Report stating that the deficiency was corrected.
Fire Fighting › Remote Fuel Shutoff › General
Issued 5 May 2016
Resolved
0750-Fire Prevention. Air supply to the quick close vavles was in the closed position rendering the four fuel valve groups served by designed to be closed in the event of a fire inoperable. SOLAS II-2/14.1
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 7 May 2016
Resolution: Recieved a Bureau Veritas Class Report stating that the deficiency was corrected.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 5 May 2016
Resolved
0715-Detection. PSCO's noted that there were numerious smoke detector and flame detectors throughout the engineroom that were being held together with tape. PSCO's tested 5 detectors satisfactory. SOLAS II-2/14.1
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 7 May 2016
Resolution: Recieved a Bureau Veritas Class Report stating that the deficiency was corrected.