MAURY USCG vessel records Sign in
← All vessels

BALTIC ADVANCE

BALTIC ADVANCE is a 2006 tank ship. The Coast Guard has recorded 11 inspections since 2006, most recently in May 2012, along with 3 deficiencies and 4 operational controls.

Records from 2006 to 2012. Most recent: operational control imposed, 19 May 2012.

Built
2006
Last inspected
16 May 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9299862 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
806664
Flag
CYPRUS
—
Maury page id
psix-806664

Inspections, by type

…with no type recorded5
Years with a record 4 calendar years (2006–2012)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10110 - Simplified, Net Ton
45974 - Displacement, Ton
37332 - Dead Weight, Ton
23240 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 11

16 May 2012 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4313025
8 February 2012 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4240441
3 February 2012 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4237886
5 June 2008 Ballast Water Examination · COC-TVE Renew · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3228348
17 May 2007 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2933313
10 May 2007 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2926801
11 August 2006 ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2747358
5 May 2006 Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2641317
25 February 2006 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2591821
24 February 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2591715
21 February 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2589064

Deficiency record · 3

Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 8 February 2012 Resolved
The IGS is not operational. The main burner is unable to produce a flame and therefore the inert gas cannot be produced. (SOLAS 2009, Reg. 5.5.1.1 and FSS Code, Ch. 15.2.1.2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2012
Resolution: Received a satisfactory class report attesting that the Inert Gas Generator has been repaired by the ship''s crew, tested and found in good order.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 8 February 2012 Resolved
The IGG flexible fuel delivery line for the main burner was leaking fuel. (SOLAS 2009, Reg. 5.5.1.1 and FSS Code, Ch. 15.2.1.2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2012
Resolution: Received a satisfactory class report attesting that the broken flexible hose has been replaced by a spare one with the same specifications and pressure tested in the presents of the surveyor.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 May 2007 Resolved
The display screen on the OWS was not functioning. The OWS was operational but the PPM amount could not be displayed.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2007
Resolved 17 May 2007

Ownership record