Records in 2016. Most recent: inspection, 4 October 2016.
Documentation record
Tonnage as PSIX records it29377 - Simplified, Gross Ton
29377 - Convention (Subpart B), Gross Ton
17592 - Convention (Subpart B), Net Ton
17592 - Simplified, Net Ton
52677 - Dead Weight, Metric Ton
60768 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Engineering › Sea-water System (primary cooling) › Piping
Issued 4 October 2016
Resolved
2545: The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons onboard. Temporary patches were found on the fresh water generator, upper sea chest, main S/W line to main engine, #2 S/W outlet; See Narrative
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2016
Resolved 11 October 2016
Resolution: Received, reviewed, and accepted BV Class Report attesting to repair and renewal of deficient items. A condition of class was issued for the upper sea chest to be permanently repaired within 3 months.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Location
Issued 4 October 2016
Resolved
0715: The function of fixed fire detection shall be periodically tested by means of equipment producing hot air at the appropriate temperature, or smoke or aerosol particles or other phenomena associated with incipient fires to which the detector is designed to respond. Crew does not have appropriate means to safely test fire detection above main engine. 74 SOLAS (14) II-2/7.3.2 (17ac)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2016
Resolved 11 October 2016
Resolution: Received reciept for proper testing equipment.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 4 October 2016
Resolved
2120: Every ship of 100 GT and above shall carry a Garbage Management Plan that shall provide written procedures for collecting, storing, processing and disposing of garbage. The Garbage Management Plan on board provided insufficient instructions for category F and Bio-Hazardous waste as required by the Bio-Fouling Management Plan, MARPOL Annex V/10, 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2016
Resolved 4 October 2016
Resolution: Discussed items with the [name withheld] and Chief Engineer.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 4 October 2016
Resolved
2510: Any vessel equipped with ballast tanks must maintain a Ballast Water Management Plan that has been developed specifically for the vessel. Ballast handling logs that the crew is using in no in accordance with the plan. Bio-Fouling record keeping is not being followed and VGP record keeping is incorrect, 33CFR151.2050(g), 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2016
Resolved 4 October 2016
Resolution: Discussed all items with the [name withheld] and Chief Engineer.
Personnel › Training › Fire Fighting Basic
Issued 4 October 2016
Resolved
2020: Performance of crewmembers assigned fire-fighting duties shall be periodically evaluated by conducting on-board training and drills to identify areas in need of improvement, to ensure competency in fire-fighting skills is maintained and to ensure the operational readiness of the fire fighting organization. Crew failed first and second fire drills for the following reasons: See Narrative.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 October 2016
Resolved 4 October 2016
Resolution: Discussed basic fire procedures with the Captain, [name withheld], Chief Engineer and all other crewmembers.