MAURY USCG vessel records
← All vessels

SFL COMPOSER

SFL COMPOSER is a 2005 freight ship. The Coast Guard has recorded 25 inspections since 2016, most recently in March 2026, along with 11 deficiencies and 2 operational controls.

Records from 2016 to 2026. Most recent: inspection, 12 March 2026.

Built
2005
Last inspected
12 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 March 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9293583
807001
Flag
LIBERIA
Maury page id
psix-807001

Documentation record

Tonnage as PSIX records it18881 - Dead Weight, Metric Ton
34063 - Displacement, Metric Ton
58631 - Convention (Subpart B), Gross Ton
17590 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 25

12 March 2026 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8322889
1 December 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8275743
7 November 2025 PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8264596
14 October 2025 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8250965
2 July 2025 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8173378
17 May 2025 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8138063
2 May 2025 PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8124001
24 October 2024 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8019976
21 March 2024 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7880479
28 November 2023 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7833195
24 February 2023 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7640213
16 September 2022 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7560386
18 July 2022 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7503382
18 July 2022 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7509852
30 April 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7441146
11 April 2022 PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7428505
1 April 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7422931
16 March 2022 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7412772
21 May 2020 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6958007
25 March 2019 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6649001
10 May 2018 ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6406428
5 February 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6350008
26 April 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6128748
25 April 2017 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6134742
7 March 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5825909

Deficiency record · 11

07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 11 April 2022 Resolved
07117 - MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS AND TO LIMIT THE ACCUMULATION OF FLAMMABLE LIQUIDS. PSCO OBSERVED FUEL OIL LEAK SPRAYING FROM THE HIGH PRESSURE FUEL OIL LINE LEADING TO THE #3 FUEL PUMP ON THE #3 M. D. GENERATOR. 74 SOLAS (2004) II-2/4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2022
Resolution: Class society provided report attesting to repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 April 2022 Resolved
13199 - THE MACHINERY ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. PSCO OBSERVED OIL SEEPING FROM WELDS ON #2 GENERATOR OIL FILTER PIPING. CHIEF ENGINEER STATED THAT CREW REPAIRED CRACKS FOUND ON PIPE BUT COULD NOT PROVIDE ANY DOCUMENTATION STATING REPAIRS WERE APPROVED BY ADMINISTRATION. 74 SOLAS (2004) II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2022
Resolution: Class society provided report attesting to repair.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 11 April 2022 Resolved
02118 - WHENEVER A DEFECT IS DISCOVERED THE MASTER OR OWNER OF THE SHIP SHALL REPORT AT THE EARLIEST OPPORTUNITY TO THE ADMINISTRATION, THE NOMINATED SURVEYOR OR RECOGNIZED ORGANIZATION RESPONSIBLE FOR ISSUING THE RELEVANT CERTIFICATE. PSCO OBSERVED FUEL OIL SEEPING FROM WELD ON FRAME #125 BULKHEAD ABOVE PORT SIDE FUEL OIL TANK. [name withheld] STATED THAT TEMPORARY REPAIRS WERE CONDUCTED BY PREVIOUS CREW. MASTER WAS UNABLE TO PROVIDE DOCUMENTATION STATING THAT TEMPORARY REPAIRS WERE APPROVED BY THE ADMINISTRATION. 74 SOLAS(2020) 1/11(c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 11 April 2022
Resolved 16 September 2022
Resolution: Received Class Survey attesting to repairs and rectifying this deficiency.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 11 April 2022 Resolved
15102 - THE COMPANY SHOULD ESTABLUISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN CONFORMITY WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATION AND WITH ANY ADDITIONAL REQUIREMENTS WHICH MAY BE ESTABLISHED BY THE COMPNAY. VESSEL MASTER PROVIDED EVIDENCE THAT THE COMPANY WAS NOTIFIED ON THE ITEMS #2, #3 LISTED ABOVE. HOWEVER, WAS NOT ABLE TO RPOVIDE DOCUMENTATION STATING THAT THER TEMPORARY REPAIR ON THE #2 FO TANK AND THE REPAIRS ON THE @2 mdg OIL FILTER PIPING WERE APPORVED BY THE ADMINSTRATION. DUE TO THE OBJECTIVE EVIDENCE IN THE ABOVE DEFINCIENCIES, THE VESSEL IS NOT IN SUBSTANTIAL COMPLIANCE WITH RELEVANT CONVENTIONS. THE CAPTAIN OF THE PORT QUESTIONS THE ADEQUACY AND OVERALL IMPLEMENTATION OF THE VESSEL'S SMS UNDER THE ISM CODE. AN INTERNAL AUDIT IS REQUIRED WITHIN 30 DAYS TO DETERMINE WHETHER THE SHIP IS OPERATING IN ACCORDANCE WITH THE ISM CODE. PROVIDE A COPY OF THE AUDIT REPORT TO USCG WHEN COMPLETED. 74 SOLAS (2020)IX/3.1 ISM CODE 10.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 April 2022
Resolution: Received ISM Audit and Report attached to this activity under documents.
01 - Certificates & Documentation › 013 - Documents › Cargo record book
Issued 16 March 2022 Resolved
Cargo, cargo units, and cargo transport units shall be loaded, stowed and secured throughout the voyage in accordance with the cargo securing manual approved by the Administration. PSCO found cargo shift and damage following reported heavy weather. Prior to movement, secure cargo to the satisfaction of the Administration. 74SOLAS(20)VII/5 Action taken: 60bc
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 16 March 2022
Resolved 18 March 2022
Resolution: DNV class report recieved, attesting to vehicles re-stowed IAW Cargo Securing Manual.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 March 2022 Resolved
A safety system shall be provided to ensure that serious malfunction in machinery or boiler operations, which present immediate danger, shall initiiate the automatic shutdown of that part plant and that an alarm shall be given. Vessel experianced a loss of propulsion in heavy weather. PSCO found low lube oil alarm in history, but low main engine oil pressure, which should have casued engine shutdown, was not recorded or observed. 74SOLAS(04)II-1/52 action taken: 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 17 March 2022
Resolved 17 March 2022
Resolution: Vessel lost suction on the #1 LO sump pump, which triggered a stop of the pump. #2 LO sump pump started, not in enough time for a loss of oil pressure alarm to be detected and a low alarm/shutdown of the MDE, in alignement with class rules & automation.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 16 March 2022 Resolved
Satisfactory means for safe passage required by regulation 25-1 shall be provided for the protection of the crew. PSCO observed damage to handrails on ladderway between cargo decks 1 & 2 and stanchions on cargo ramp from deck 6 to 7 ICLL I/25.4 action taken: 40ac
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 March 2022
Resolved 1 April 2022
Resolution: Vessel report showing handrails were repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 March 2022 Resolved
Whenever there is a hazardous condition either onboard a vessel or caused by a vessel or its operations, the owner, agent, master, operator, or person in charge must immediately notify the nearest Coast Guard sector office. Vessel failed to notify Sector SE New England following heavy weather that caused a loss of propulsion and shifting cargo 33CFR160.216(a) action taken: 10c
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 17 March 2022
Resolved 17 March 2022
Resolution: Notification found.
Engineering › Steering Gear System › Pump
Issued 5 February 2018 Resolved
Vessel reported failure of Steering Gear.
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 5 March 2018
Resolved 7 February 2018
Resolution: Vessel provided Class Report and satisfactory port state control exam.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 26 April 2017 Resolved
In the event of an emergency the echo sounder record shall be removed, properly identified with the vessel's name and date in ink, signed by the master and the OOW at the time of the emergency. On April 25, 2017 the vessel ran aground outside Brunswick Pilot Station. The echo sounder record was set at 250 meter range at the time of the grounding. SOLAS74/78(14CONS)IX/REG4.3 (17ac)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2017
Resolved 26 April 2017
Resolution: Vessel's crew conducted training on the echo sounding device. Crew changed the scale of the depth on the echo sounding device to proper depth needed for safe voyage.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 26 April 2017 Resolved
When an accident occurrs to a ship, the organization responsible shall initiate an ivestiagation. On April 25, 2017 at approximately 1550 local time, the MV GLOVIS COMPOSER reported to have ranve aground. The vessel shall provide survey report from the company attesting to the seaworthiness of the vessel. SOLAS74/78(14Cons)I/REG11.C (17ac)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2017
Resolved 26 April 2017
Resolution: MSU Savannah received survey report from class attesting to the seaworthiness of vessel.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.