CALIPSO is a 2004 freight ship. The Coast Guard has recorded 10 inspections since 2016, most recently in February 2025, along with 8 deficiencies and 4 operational controls.
Records from 2016 to 2025. Most recent: inspection, 9 February 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it31917 - Simplified, Gross Ton 40230 - Convention (Subpart B), Gross Ton 86034 - Displacement, Metric Ton 73690 - Dead Weight, Metric Ton 26314 - Convention (Subpart B), Net Ton 25533 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 10
9 February 2025MARPOL Annex V Examination · MARPOL Annex I Examination · MARPOL Annex VI Survey · PSC A · MARPOL Annex II Examination
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 9 February 2025Resolved
PERSONAL EQUIPMENT SHALL CONSIST OF THE FOLLOWING... PROTECTIVE CLOTHING OF MATERIAL TO PROTECT THE SKIN FROM THE HEAT RADIATING FROM THE FIRE AND FROM BURNS AND SCALDING BY STEAM. THE OUTER SURFACE SHALL BE WATER-RESISTANT. PSCO OBSERVED TEARS IN FIRE FIGHTING HOODS, NOT PROTECTING THE SKIN FROM HEAT.
74 SOLAS 09 II-2/10.10.1
FSS CODE CH.3.2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2025
Resolved 15 May 2025
Resolution: Vessel sent receipts and approval certificates for new firefighting suits.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 February 2025Resolved
THE PURPOSE OF THIS REGULATION IS TO MAINTAIN AND MONITOR THE EFFECTIVENESS OF THE FIRE SAFETY MEASURES THE SHIP IS PROVIDED WITH. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: FIRE PROTECTION SYSTEMS AND FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE MAINTAINED READY FOR USE... 02 CARBON DIOXIDE CYLINDERS HAD PINS INSTALLED PREVENTING IMEEDIATE USE.
74 SOLAS 09 II-2/14.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 February 2025
Resolved 9 February 2025
Resolution: PINS WERE REMOVED.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 February 2025Resolved
EXPOSED METAL PARTS OF ELECTRICAL MACHINES OR EQUIPMENT WHICH ARE NOT INTENDED TO BE LIVE BUT WHICH ARE LIABLE UNDER FAULT CONDITIONS TO BECOME LIVE SHALL BE EARTHED UNLESS THE MACHINES OR EQUIPMENT ARE SUPPLIED AT A VOLTAGE NOT EXCEEDING 250V BY SAFETY ISOLATING TRANSFORMERS SUPPLYING ONLY ONE CONSUMING DEVICE. MULTIPLE MOTORS IN THE PURIFIER SPACE AND ENGINE ROOM WITH EARTHING WIRES WERE DISCONNECTED.
74 SOLAS 04 II-1/45.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 February 2025
Resolved 9 February 2025
Resolution: GROUNDING WIRES WERE REINSTALLED.
Fire Fighting › Remote Fuel Shutoff › General
Issued 29 December 2017Resolved
0750-Fire Prevention-Oil fuel pipes, which if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500L and above shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. PSCO observed the quick closing valves of the main MGO service tank were intentional disabled by blocking air supply with a plug. SOLAS 74(a) II-2/4.2.2.3.4 30a
Action required: 60 - Rectify deficiencies prior to movement
Due 30 December 2017
Resolved 30 December 2017
Resolution: 30DEC17: Received, reviewed and accepted class report from DNV-GL satisfying outstanding requirements related to the detention.
0699- Other (Life saving)- Muster and embarkation stations shall be adequately illuminated.
PSCO observed emergency lighting was not adequately providing light for the embarkation stations.Solas 74(a) III/11.4 17a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2017
Resolution: Received, reviewed and accepted class report from DNV-GL satisfying outstanding requirements related to emergency lighting.
1730-Oily water separtating equipment- A 15 PPM bilge alarm should record date, time and status and operating status of the 15 PPM bilge separator. The recording device should also store data for at least 18 months and should be able to display or print a protocol for official inspections. PSCO observed that the oil content meter could not recall data or display history of past usage. MARPOL ANNEX I/14.6 MEPC.107(49) 17a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2017
Resolution: Received, reviewed and accepted class report from DNV-GL satisfying outstanding requirements related to OWS
1510-Navigation Equipment-If the vessels automatic identification system (AIS), radar, radio navigation receivers, gyrocompass, or echo depth sounding device stops working properly the person directing the movement of the vessel must report that it is not operating properly to the nearest Captain of the Port. PSCO observed that the echo depth sounder was not working. 33CFR 164.53(b) 16b
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 18 August 2018
Resolution: PSC NOLA RECEIVED A CLASS REPORT FROM ABS SATISFYING THE REQUIREMENT.
Construction/Loadline › Structures › Deck Plating
Issued 29 December 2017Resolved
0988- Deck-Corrosion- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed that various sections of steel covering the hydraulic lines and electrical conduit has corroded beyond repair 74 SOLAS (a) REG. 1/11(a) 16a
Action required: 705 - Other - as specified
Due 12 January 2018
Resolved 18 August 2018
Resolution: PSC NOLA RECEIVED A CLASS REPORT FROM DNV-GL SATISFYING THE REQUIREMENT.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.