MSC MICHIGAN VII is a 2000 freight ship. The Coast Guard has recorded 20 inspections since 2016, most recently in July 2024, along with 10 deficiencies — 1 with no resolution recorded — and 7 operational controls.
Records from 2016 to 2024. Most recent: inspection, 20 July 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it74583 - Convention (Subpart B), Gross Ton 81462 - Dead Weight, Metric Ton 107762 - Displacement, Metric Ton 41490 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 July 2024Resolved
Means ahll be provided so that main propulsion can be restored in the event an essential auxiliary becomes inoperative. PSCO observed that ship's #2 air compressor had a defective sealing gasket was leaking excessively.
SOLAS (2020 Cons) II-1/26.3.9.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 July 2024
Resolved 22 July 2024
Resolution: Received BV class report. Gasket was repaired and AC tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 July 2024No resolution recorded
Machinery, associated piping systems and fitting shall be adequate for intended purpose. Following extensive repairs to the ship's main disel engine (MDE), the technicians's service report (MAN PrimeServ Canada report of 12 July 2024) provided 13 recommendations to improve the safe and efficient operation of the MDE. These recommendations are to be addressed or resolved to the satisfactor of the Administration or classification society.
SOLAS (2020 Cons) II-1/26.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 July 2024 — due date passed with no resolution recorded
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 8 June 2024Resolved
The safety management system should provide for safe practices in ship operation and a safe working environment. During a more detailed inspection following a marine casualty, objective evidence indicated that the crew is not analyzing non-conformities, accidents and hazardous occurrences (ISM Code 9); did not adequately maintain the ship and equipment (ISM Code 10); and failed to produce various documentation related to the maintenance of critical equipment (ISM 11). The crew stated that MDE was unreliable at maneuvering speeds following the ship's dry docking in Nov 2023. No objective evidence was provided that that MDE unreliability was investigated and analyzed by the Company. Also, no documentation was provided related to MDE
maintenance activities at the shipyard, despite the installation of Engine Power Limiter. Further, the shipboard engineering alarm printer was jammed, with the printer printing over itself on the same line of paper since Feb. PSCO also observed multiple leaking fuel valves, inoperable fuel/lube oil purifiers, and a leaking fuel tank w/pooled fuel oil. A SMS audit is required to be carried out before the ship may be released from detention.
74 SOLAS (2020 cons.) IX/3.1
ISM Code 1.2.2.1
30ac
Action required: 30 - Ship detained
Resolved 22 July 2024
Resolution: Received ISM Audit Report. See deficiency documents tab.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 June 2024Resolved
The speed and direction of thrust shall be fully controllable from the navigation bridge under all sailing conditions, including maneuvering. Main Diesel Engine governor was found to be faulty resulting in a loss of throttle control and uncontrolled acceleration of the ship through Charleston Harbor.
**PSC Exam is suspended in accordance with the Procedures for Port State Control Ch. 3.6. The Administration is required to verify compliance with all applicable conventions and regulations.**
74 SOLAS (2004 cons.) II-1/31.2
30ac
Action required: 30 - Ship detained
Resolved 22 July 2024
Resolution: Received service report. See deficiency documents tab.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 February 2024Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED EXCESSIVE OIL ACCUMULATION ON MAIN DIESEL GENERATORS #3 AND #4. 74 SOLAS (20) II-2/4.1.3 - 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2024
Resolved 4 March 2024
Resolution: Received report from Flag verifying no continued leakage of accumulation on the #3 or #4 main diesel generators.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 February 2024Resolved
THE FIXED FIRE DETECTION SYSTEM SHALL INITIATE AUDIBLE AND VISUAL ALARMS...TOENSURE THAT THE ALARMS ARE HEARD AND OBSERVED ON THE NAVIGATION BRIDGE AND BY A RESPONSIBLE ENGINEERING OFFICER. SMOKE DETECTOR IN ENGIVE CONTROL ROOM DID NOT PRODUCE AN AUDIBLE ALARM. 74 SOLAS (20) II-2/4.2 - 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 February 2024
Resolution: Ship's electrictian was able to make repairs to faulty fire alarm. PSCOs witnessed satisfactory test of the affected detector.
ANY MAIN AND AUXILIARY STEERING GEAR, IN THE EVENT OF A FAILURE OF ELECTRICAL POWER SUPPLY TO THE CONTROL SYSTEM, AN AUDIBLE AND VISUAL ALARM SHALL BE GIVEN ON THE NAVIGATION BRIDGE. LOSS OF POWER ALARM WAS NOT GIVEN ON THE BRIDGE. 74 SOLAS (20) II-1/29.8.4 - 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 February 2024
Resolution: Ship's personnel replaced faulty bulbs on steering gear alarm panel on nav. bridge. PSCOs verified proper operation while onboard.
HYDRAULIC POWER-OPERATED STEERING GEAR SHALL BE PROVIDED WITH A LOW-LEVEL ALARM FOR EACH HYDRAULIC FLUID RESERVOIR. AUDIBLE AND VISUAL ALARMS SHALL BE PROVIDED ON THE NAV. BRIDGE AND IN THE MACHINERY SPACE. ALARMS WERE NOT GIVEN FOR #1 STEERING GEAR RESEVOIR WITHIN THE MACHINERY SPACE. 74 SOLAS (20) II-1/29.12.2 - 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2024
Resolved 4 March 2024
Resolution: Received report from flag verifying testing of the low-level alarm for the hydraulic fluid reservoir. Audible and visual alarms were tested from local, the ECR and bridge.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 February 2024Resolved
ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT THE SAFETY OF CREW AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED. UNAPPROVED INSTALLATION OF A 440 VOLT RECEPTACLE FOR AN SCBA COMPRESSOR WAS INSTALLED TO THE EMERGENCY GENERATOR. 74 SOLAS (20) II-1/40.3 - 10c
See photos in DOCUMENTS.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 17 February 2024
Resolution: Ship's electrician removed un-approved 440V receptacle from the emegency generator space.
Engineering › Freshwater Generation System › Piping
Issued 28 April 2017Resolved
AFTER ANY SURVEY OF THE SHIP HAS BEEN CONDUCTED NO CHANGE SHALL BE MADE ON THE STRUCTURE ARRANGEMENTS, MACHINARY,EQUIPMENT, AND OTHER ITEMS COVERED BY SURVEY. WITHOUT THE SUCTION PIPE ON THE CONDENSER LOCATED ON THE FRESH WATER GENERATOR IS FITTED WITH A C CLAMP AND COVERED WITH SYNTHOGLASS. 74SOLAS(2014 CONS) 1/11
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 May 2017
Resolved 3 June 2017
Resolution: Received attestation for the repairs.