MAURY USCG vessel records
← All vessels

DOUBLE SKIN 56

Built
2006
Last inspected
6 August 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 6 August 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 20 calendar years (2006–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

807181
Flag
UNITED STATES
Maury page id
psix-807181

Documentation record

Registered dimensions (L × B × D)348.0 ft × 62.0 ft × 24.5 ft
Registered tonnagegross 4,235 / net 2,521
ITC dimensions (L × B × D)348.0 ft × 62.0 ft × 24.5 ft
ITC tonnagegross 4,235 / net 2,521
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2006
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBALTIMORE, MD
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4235 - Convention (Subpart B), Gross Ton
2521 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 43 inspections, each with its date, unit and type; 36 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 3 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPTAIN WILLIE LANDERS Towing Vessel · MISLE 22966 · 6 April 2018 · activity 6388028SUSQUEHANNA Towing Vessel · MISLE 924966 · 6 April 2018 · activity 6388028MARILYN GEORGE Towing Vessel · MISLE 662923 · 4 February 2016 · activity 5811175

Inspection history · 43

6 August 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8203172
16 October 2024 Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8019891
21 May 2024 Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7917446
13 May 2024 Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7911665
23 April 2024 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7899935
21 March 2024 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7882752
22 August 2023 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7774120
29 September 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7568691
13 September 2022 Deficiency Check · MTSA Verification · Annual Inspection · Examination of Repairs
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7558040
10 June 2021 Drydock Exam · COI Inspection · MTSA Verification · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7221425
19 November 2020 Bulk Liquid Transfer Monitor
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7101178
7 August 2020 Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7026302
15 March 2019 Deficiency Check · Administrative Inspection · MTSA Verification · Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6644526
14 May 2018 Deficiency Check · MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6414324
6 April 2018 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6388028
14 June 2017 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6174591
13 June 2016 MTSA Verification · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5906421
20 May 2016 Internal Structural Exam · Hull Examination · Cargo Tank Internal
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5881796
5 February 2016 Damage Survey · In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5810369
4 February 2016 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5811175
17 November 2015 Administrative Inspection · SIP Initial Entry
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5764929
26 August 2015 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5227031
22 July 2015 MARPOL Annex I Examination · MTSA/ISPS Verification · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5192161
30 April 2014 Annual Inspection · Deficiency Check · SIP Inspection/Audit · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4847484
26 August 2013 MTSA Verification · SIP Inspection/Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4697432
11 July 2013 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4650118
12 September 2012 SIP Inspection/Audit · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4445012
8 July 2011 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4074185
21 June 2011 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4052606
13 June 2011 Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4043194
10 December 2010 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3908202
24 August 2010 Cargo Tank Internal · SIP Inspection/Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3832016
2 March 2010 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3688484
21 August 2009 Internal Structural Exam · SIP Inspection/Audit · Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3569732
25 September 2008 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3332176
6 December 2007 SIP Initial Entry
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3176068
14 August 2007 MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3027432
8 May 2007 SIP Initial Entry
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3176005
30 October 2006 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2810363
11 September 2006 Initial Certification · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2775687
12 July 2006 SIP Initial Entry
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3175942
26 April 2006 Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2633715
21 April 2006 Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2801411

Deficiency record · 36

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 October 2024 Resolved
Each outlet or junction box must be secured or attached to its mounting and be affixed so as to maintain its designated degree of protection. Lighting fixture on the starboard side cargo pump room requires proper mounting.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2024
Resolved 6 August 2025
Resolution: Cleared previously (see docs).
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 October 2024 Resolved
Class 1 Division 1 locations may have only approved intrinsically safe, explosion proof, or purged and pressurized electrical equipment, and through runs of marine shipboard cable if the location is- (1) within 10 feet of: (iii) A cargo pipe flange. Port and starboard pump room battery boxes are within 10 feet of a cargo pipe flange.
Action required: 705 - Other - as specified
Resolved 6 August 2025
Resolution: Observed no battery box within 10 ft.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 May 2024 Resolved
No extensive alterations involving the safety of a tank vessel either in regard to hull or machinery shall be made without the approval of the Commandant. Perform temporary repairs to whole found in the FWD rake Port side in accordance with ABS approved temporary repair proposal.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 May 2024
Resolved 14 May 2024
Resolution: Temporary repair made with JB weld. See documents for pictures.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2024 Resolved
The Officer in Charge, Marine Inspection, may issue a permit to proceed to another port for repair. Vessel is required to receive an approved permit to proceed prior to its departure to the Tampa Captain of the Port zone.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2024
Resolved 14 May 2024
Resolution: Permit to Proceed signed and issued.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 May 2024 Resolved
No extensive alterations involving the safety of a tank vessel either in regard to hull or machinery shall be made without the approval of the Commandant. Perform permanent repairs to hole found in the FWD rake Port side to the satisfaction of the cognizant OCMI.
Action required: 705 - Other - as specified
Due 5 June 2024
Resolved 28 May 2024
Resolution: Permanent repairs verified and found to be satisfactory.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 13 September 2022 Resolved
Cargo pump relief valves shall be tested at least once each year to determine that they function satisfactorily at the pressure at which they are set to open. The previous test was conducted 23JUL2021 and the vessel representative could not provide proper documentation the port and starboard cargo pump relief valves had been tested within the past year. Provide proper documentation a test has been completed within the last 12 months or test to the satisfactory of a CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2022
Resolution: Reviewed current test records for both cargo pump relief valves.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 13 September 2022 Resolved
Cargo pump pressure gauge shall be tested at least once a year for accuracy. The previous test was conducted 23JUL2021 and the vessel representative could not provide proper documentation the port and starboard cargo pump pressure gauges had been tested within the past year. Provide proper documentation a test has been completed within the last 12 months or test to the satisfactory of a CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2022
Resolution: Barge received new gauges with recent test documentation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 September 2022 Resolved
Each cable entrance into explosion proof or flame proof equipment must be made with approved seal fittings, termination fittings, or glands that meet the requirements of 46 CFR 111.105-9. The seal fitting to the #5 port side high level/over fill device on deck and in a hazardous location found wasted away and is no longer providing explosion proof or flame proof protection. Repair to the satisfaction of the attending CG Marine Inspector prior to carrying cargo in #5 port tank.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2022
Resolution: Fitting renewed, satisfactorily tested high level and overfill alarms.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 September 2022 Resolved
At least one lifebuoy on each side of the vessel fitted with a buoyant lifeline. The forward life buoy’s buoyant lifeline was found broken and tied back together. Additionally, the line is crumbling apart. Replace buoyant lifeline with an approved type to the satisfaction of a CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 September 2022
Resolution: Lifeline replaced with an approved type.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 September 2022 Resolved
The lifebuoys shall be fitted with retro-reflective material (tape) with a minimum of 5 cm (2 inches) width around the lifebuoy at four locations spaced equally around the circumference of the lifebuoy. Retro-reflective material shall be Type II material that is approved under 46 CFR 164.018. Both life buoys had faded retro-reflective tape. Repair to the satisfaction of the attending CG Marine Inspector. 46 CFR 160.150-3(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 September 2022
Resolution: Retro-reflective tape renewed on both life buoys.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 13 September 2022 Resolved
Each hose must be marked with date of the latest test required by 33 CFR 156.170. Diesel fuel oil transfer hose was not labeled with latest test date. Label hose with last test date to the satisfaction of the attending CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 September 2022
Resolution: Diesel fuel oil transfer hose labeled appropriately.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 September 2022 Resolved
Where fitted, it shall be the duty of the master to see that the emergency lighting and power systems are tested and inspected at least once in each week that the vessel is navigated to be assured that the system is in proper operating condition. Emergency lighting in the cabin was inoperable. Repair to the satisfaction of the attending CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 September 2022
Resolution: Emergency lighting tested satisfactorily.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 13 September 2022 Resolved
Each valve shall be legibly marked with the style, type or other designation of the manufacturer, the size, pressure and vacuum setting and name or registered trademark of the manufacturer and Coast Guard approval number. The minimum wording for showing the approval number shall be “USCG/162.017/* *” or “USCG 162.017-* *”. HVPVs were not labeled with serial number, pressure data, or test dates. Provide documentation from the tests and label valves to the satisfaction of the attending CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 29 September 2022
Resolution: Received objective evidence new manufacturer placards were ordered, embossed with proper information, and affixed to both VCS HVPVs. Satisfactory testing documentation for both HVPVs was verified by USCG Marine Inspector.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 August 2021 Resolved
EACH CARGO TANK OF A TANK BARGE MUST HAVE AUDIBLE AND VISUAL HIGH-LEVEL AND TANK OVERFILL ALARMS. VESSELS HIGH-LEVEL AND TANK OVERFILL ALARMS FOR TANK ONE ON STARBOARD SIDE 1S INOPERABLE. VESSEL IS NOT PERMITTED TO ONLOAD CARGO IN TANK 1S UNTIL PROOF OF PROPER OPERATION OF ALARMS. 46CFR39.2009
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2021
Resolved 17 August 2021
Resolution: MI WITNESSED OPERATIONAL TESTING OF VESSELS HIGH-LEVEL AND TANK OVERFILL ALARMS FOR TANK ONE ON STARBOARD SIDE. CLEARED 835.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 March 2019 Resolved
Replace all wasted hydraulic line valve handles and cargo pump gauge valve handles IAW 46 CFR 56.20-9(a).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 March 2019
Resolution: 14 handles replaced
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 March 2019 Resolved
Repair cracked weld in the #3 starboard void tank located 3 bays forward of the after ladderwell and 2 bays inboard from the side shell. 46 CFR 31.10-21(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 March 2019
Resolution: Grinded and re-welded.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 18 March 2019 Resolved
Replace gaskets in void tank hatch covers. 46 CFR 31.25-1.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 March 2019
Resolution: Replaced all gaskets.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 18 March 2019 Resolved
Prove proper reinstallation of the port cargo pump to attending CG marine inspector prior to cargo operations w/ pump. Pump was removed at the time of inspection for maintenance. 46 CFR 32.50-1
Action required: 705 - Other - as specified
Resolved 26 March 2019
Resolution: Witnessed the cargo pump installed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 18 March 2019 Resolved
Crop and renew cracked longitudinal in #2 port void located on the side shell 3 bays fwd from aft ladderwell and 4th longitudinal from bottom.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 March 2019
Resolution: Cropped and renewed longitudinal.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 March 2019 Resolved
Repair cracked weld on fwd frame in #1 stbd void located 8 bays aft of the fwd ladderwell approximately 4 feet up from the deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 March 2019
Resolution: Grinded and re-welded.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 March 2019 Resolved
Repair cracked weld in #2 stbd void where the 4th side shell longitudinal meets the aft frame. Located 1 bay aft of the fwd ladderwell.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 March 2019
Resolution: Grinded and re-welded.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 March 2019 Resolved
Repair cracked weld in #2 stbd void on 4th side shell longitudinal approximately halfway between the frames. Located 2 bays aft of the fwd ladderwell.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 March 2019
Resolution: Grinded and re-welded.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 March 2019 Resolved
Repair cracked weld on web bracket in the forward rake located in the aft corner of the stbd side approximately 2 feet from the deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 March 2019
Resolution: Grinded and re-welded.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 14 May 2018 Resolved
Freeboard measurement on the special service load line certificate issued by ABS is not as listed on the ABS Stability Letter from 2006. Confirm accuracy of both documents.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 20 June 2018
Resolution: SSLL was corrected by ABS.
Construction/Loadline › Hull › Double Hull
Issued 14 May 2018 Resolved
Conduct repairs identified in #1 & #2 stbd voids to the satisfaction of the attending USCG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 22 June 2018
Resolution: All hot work approved by ABS and USCG.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 July 2015 Resolved
Prove proper operation of emergency lights in generator space and crew quarters.
Condition: Improper/Lack of Maintenance
Due 23 July 2015
Resolved 23 July 2015
Resolution: Replaced dead batteries.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 July 2015 Resolved
Renew markings on life ring buoys to include name and hailing port.
Condition: Improper/Lack of Maintenance
Due 22 July 2015
Resolved 22 July 2015
Resolution: Restenciled ring buoys.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 July 2015 Resolved
Make navigation light screens matter black, as original.
Condition: Improper/Lack of Maintenance
Due 29 July 2015
Resolved 23 July 2015
Resolution: Screen were repainted.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 22 July 2015 Resolved
Repair hatch cover for 1 starboard void, as original.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 July 2015
Resolved 23 July 2015
Resolution: Hatch cover repaired.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 22 July 2015 Resolved
Replaced lightbulb in 240V ground detection for distribution panel in generator space, as original.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2015
Resolved 23 July 2015
Resolution: Lightbulb was replaced.
Lifesaving › Hand Flares › Marking
Issued 22 July 2015 Resolved
Label container for distress signals.
Condition: Improper/Lack of Maintenance
Due 23 July 2015
Resolved 23 July 2015
Resolution: Container was labeled.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 30 April 2014 Resolved
Vapor recovery Manifold does not indicate the word VAPOR at the 10 & 2 o'clock position on the pipe line.
Due 2 May 2014
Resolved 6 May 2014
Resolution: Received pictures showing the Vapor recovery Piping system has the word "VAPOR" stenciled in black. Painting Sat.
Construction/Loadline › Hull › Double Hull
Issued 30 April 2014 Resolved
Worklist items from ISE inspection conducted on 30APR14 will be rectified prior to next credit Dry Dock Exam.
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 14 June 2016
Resolution: Completed credit drydock, worklist items corrected during drydock.
Pollution Prevention/Response › Response Equipment › Protective Clothing
Issued 30 April 2014 Resolved
Each non-self propelled ship must have a fixed or portable shower and eyewash fountain that operates during cargo transfer. As per the COI/CAA the vessel falls under 46 CFR 153. Sub Chapter O requirements.
Due 30 May 2014
Resolved 12 May 2014
Resolution: Received email from vessel representative with pictures showing the eyewash/shower station installed onboard the vessel. installation satisfactory.
Electrical › Electric Generation Source (service) › Generator
Issued 24 June 2011 Resolved
Provide generator specifications for old and new generators within 30 days. IAW 46 CFR 110.01-3
Action required: 705 - Other - as specified
Due 25 July 2011
Resolved 8 July 2011
Resolution: Generator specifications provided for old and new generators.
Construction/Loadline › Hull › Weld
Issued 21 August 2009 Resolved
Provide Repair Proposal For Discrepancies as ID'd by MI during ISE.
Action required: 705 - Other - as specified
Due 1 October 2009
Resolved 2 September 2009
Resolution: Recieved proposal to clear during next drydock.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.