← All vessels
EVROTAS
EVROTAS is a 2006 tank ship. The Coast Guard has recorded 33 inspections since 2006, most recently in December 2025, along with 5 deficiencies and 4 operational controls.
Records from 2006 to 2025. Most recent: inspection, 5 December 2025.
- Built
- 2006
- Last inspected
- 5 December 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9309241 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A8HR9
807608
Flag
LIBERIA
—
Maury page id
psix-807608
Inspections, by type
…with no type recorded7
Years with a record
16 calendar years (2006–2025)
The 33 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it72605 - Displacement, Metric Ton
61281 - Dead Weight, Metric Ton
35711 - Convention (Subpart B), Gross Ton
16707 - Convention (Subpart B), Net Ton
61281 - Dead Weight, Metric Ton
35711 - Convention (Subpart B), Gross Ton
16707 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 33
5 December 2025
Administrative Inspection · PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8273774
29 November 2024
PSC B · COC-TVE Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8039791
29 March 2024
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7887068
27 March 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7886022
2 November 2023
COC-TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7815239
12 December 2022
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7608113
6 October 2022
COC-TVE Annual · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7568442
6 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7448594
8 September 2021
PSC B · Deficiency Check · COC-TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7298472
21 June 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7231402
31 August 2020
PSC B · COC-TVE Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7046756
5 August 2019
ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6769499
30 April 2018
COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6396192
24 April 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6394590
2 December 2017
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6316808
10 April 2017
Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6113604
4 May 2016
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5867441
17 December 2011
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4209942
18 February 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3948259
25 October 2010
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3876996
19 February 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3691705
18 February 2010
Ballast Water Examination · ISPS III Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3680583
23 April 2009
Random ISPS/MTSA/PSC · COE-Dockside
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3458761
24 March 2009
Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3443177
23 March 2009
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3438111
16 May 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3200144
5 March 2008
Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3158572
6 April 2007
MARPOL Annex I Examination · MARPOL Annex V Examination · COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2902480
26 January 2007
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2846017
12 September 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2773290
12 April 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2623061
7 April 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2619845
6 March 2006
Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2596590
Deficiency record · 5
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 September 2021
Resolved
No electrical equipment shall be installed in any speace where flammable mixtures are liable to collect including onboard tankers...unless the Administration is satisfied that such equipment is of a type which will not ignite mixtures concerned. Two lighting fixtures located in the cargo pump room have damaged casing and seals.
SOLAS 76/78 (04) II-1/45.10.2
10c
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 8 September 2021
Resolved
In tankers, cargo pump rooms shall be fitted with a system for continuous monitoring of the concentration of hydrocarbon gases. The fixed gas detection system did not read the proper LEL per the test gas (+1-2%).
SOLAS 76/78 (04) II-2/4.10.3
10c
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 8 September 2021
Resolved
The venting system shall be provided with devices to prevent the passage of flame into the cargo tank based on the guidelines developed by the Organization (MSC/Circ.677). The P/V breakers flamed screens are damaged.
SOLAS 76/78 (04) II-2/5.3.3
10c
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 August 2019
Resolved
Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a Classification society. Electrical panel in Bosun stores is missing electrical packing.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 5 August 2019
Resolved
The rings, lines and letter shall be painted in white or yellow on a dark ground. The marks shall be plainly visible. Port and starboard load lines are no longer visible.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.