MAURY USCG vessel records
← All vessels

HARVEST

HARVEST is a 2005 freight ship. The Coast Guard has recorded 10 inspections since 2017, most recently in August 2021, along with 3 deficiencies and 2 operational controls.

Records from 2017 to 2021. Most recent: inspection, 20 August 2021.

Built
2005
Last inspected
20 August 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9297931
V7A2743
807624
Flag
MARSHALL ISLANDS
Maury page id
psix-807624

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
Years with a record 4 calendar years (2017–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it73690 - Dead Weight, Metric Ton
86034 - Displacement, Metric Ton
40230 - Convention (Subpart B), Gross Ton
26314 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 10

20 August 2021 Damage Survey · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7284653
29 December 2020 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7117381
21 November 2020 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7099632
21 November 2020 Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7100993
8 November 2020 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7087586
6 November 2020 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7091042
3 November 2020 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7089956
15 December 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6594096
29 November 2017 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6314867
9 January 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6061456

Deficiency record · 3

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 November 2020 Resolved
02108 -Electrical Installations in General- All electrical apparatus shall be so constructed and installed as not to cause injury when handled or touched in the normal manner. PSCO observed unprotected junction boxes for electrical wiring leading to the lighting behind the switchboard in the engine control room. Cite: 74 SOLAS(04) II-1/45.1.3 Action: 50a
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2020
Resolved 24 December 2020
Resolution: Received, reviewed and accepted BV class report stating the deficiency was rectified. The unprotected junction boxes and electrical wiring leading to the lighting behind the switchboard in the engine control room have been protected with insulation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 November 2020 Resolved
13101 - Propulson and Auxiliary Machinery- After any survey, no change shall be made in the structural arrangements, machinery, equipment, and other items covered by the survey, without the sanction of the Administration. PSCO observed missing heads on multiple jacket water casing bolts on the main diesel engine without the sanction of the Administration. Cite: 74 SOLAS (14) I/11(b) Action: 50a
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2020
Resolved 24 December 2020
Resolution: Received, reviewed and accepted BV class report stating the deficiency was rectified. The broken jacket water casing bolts (4pcs) of No.3 & 5 cylinder have been renewed.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 9 January 2017 Resolved
0715-Detection- Fire protection systems and fire fighting systems and appliances shall be maintained ready for use. PSCO observed 03 smoke detectors non- operational in the engine room over gererator sets. SOLAS 09(am) CH II-2/14.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2017
Resolved 11 January 2017
Resolution: PSC NOLA received a class report from BV satisfying the requirement.

Ownership record