MAURY USCG vessel records Sign in
← All vessels

KUSHTAKA

KUSHTAKA is a 2006 passenger vessel (inspected). The Coast Guard has recorded 10 inspections since 2006, most recently in February 2021, along with 44 deficiencies.

Records from 2006 to 2021. Most recent: inspection, 10 February 2021.

Built
2006
Last inspected
10 February 2021
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDQ6427
807800
Flag
UNITED STATES
368184090, 368443720
Maury page id
psix-807800

Inspections, by type

…with no type recorded1
Years with a record 6 calendar years (2006–2021)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)36.0 ft × 15.0 ft × 3.9 ft
Registered tonnagegross 9 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderARMSTRONG MARINE INC · PORT ANGELES, WA, UNITED STATES · built 2006
Hull materialAluminum
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationTwin Hull
Hailing portSEWARD, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ6427MMSI 368443720 · active · compulsorily equipped · granted 22 November 2025, expires 22 November 2035
WDL9994MMSI 368184090 · active · voluntarily equipped · granted 25 February 2021, expires 25 February 2031 · licensed under a name not among this hull’s recorded names (not shown)
WDG4242MMSI 367534480 · expired · compulsorily equipped · granted 9 June 2012, cancelled 13 August 2022 · licensed under a name not among this hull’s recorded names (not shown)
WDE9628MMSI 367419420 · expired · compulsorily equipped · granted 21 July 2009, cancelled 21 September 2019 · licensed under a name not among this hull’s recorded names (not shown)
WDC9511MMSI 367103240 · expired · voluntarily equipped · granted 30 March 2006, cancelled 4 June 2016 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 10

10 February 2021 Drydock Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7138751
1 June 2012 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4330233
17 May 2012 Hull Examination · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4318126
20 July 2009 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3540808
21 May 2008 DAPI Audit · Deficiency Check · Annual Inspection · MARPOL Annex II Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3308902
22 April 2008 Internal Structural Exam · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3190140
8 June 2007 Administrative Inspection · Annual Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2958812
23 May 2007 Type not recorded
No type recorded · Station Valdez · USCG Arctic District (CGD-A) · Activity 2940125
7 June 2006 In-Service Inspection · Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2677916
21 April 2006 Initial Certification · Deadweight Survey · Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2642257

Deficiency record · 44

Communications › Alarms/Indicators › Bilge Alarm
Issued 1 June 2012 Resolved
Provide visual + audible bilge high level alarms for amidships and engine compartments.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2012
Resolution: High level alarms were in existence but the crew was unaware of such existence and therefore unable to test them. Once the crew became aware of alarm operation, a deficiency check was conducted during which time a successful test was completed.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 1 June 2012 Resolved
Affix proper hailing port on stern.
Due 15 June 2012
Resolved 17 July 2012
Resolution: Hailing port affixed.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 1 June 2012 Resolved
Vessel is restricted to the carriage of 20 total persons until 10 - person life raft is serviced and installed aboard the vessel.
Due 6 July 2012
Resolved 13 June 2012
Resolution: Satisfactorily inspected liferaft installation and certification.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 21 July 2009 Resolved
Install lights on all life jackets - vessel restricted limited coastwise & nearer routes until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 21 July 2009 Resolved
Mark life jacket stowage w/appropriate numbers.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Operations/Management › Drills/Instruction › Safety Orientation
Issued 21 July 2009 Resolved
Post appropriate life jacket donning instructions.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 10 August 2009
Stability › Watertight Integrity › General
Issued 21 July 2009 Resolved
Install securing devices to both eng. wx deck hatch covers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 July 2009 Resolved
Prove proper operation of fwd p/s bilge alarms.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 21 July 2009
Engineering › Fuel Oil Service System › Piping
Issued 21 July 2009 Resolved
Install bonding cables on p/s fuel fill lines.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 3 August 2009
Resolution: Received pictures showing bonding of P&S fuel tanks.
Fire Fighting › Ventilation Systems › Ducts
Issued 21 July 2009 Resolved
Make engine vents smoketight and prove proper operation of closing devices.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Fire Fighting › Fire Bucket › Availability
Issued 21 July 2009 Resolved
Provide 2 additional 2 1/2 gallon buckets w/lanyards mark same as fire buckets prior to operation w/pax.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 August 2009
Resolved 27 July 2009
Stability › Watertight Integrity › General
Issued 21 July 2009 Resolved
Install/replace missing securing device for port fwd hatch cover.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 21 July 2009 Resolved
Obtain & keep onboard current copy of COLREG.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 July 2009 Resolved
Post stability letter and COI.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 21 August 2009
Resolution: Items Posted.
Personnel › Training › First Aid/CPR
Issued 21 July 2009 Resolved
Provide proof of CPR/First aid training for crew.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 21 August 2009
Lifesaving › Hand Flares › Quantity
Issued 21 July 2009 Resolved
Provide 3 orange day smokes & 2 red hand flares.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Operations/Management › Drills/Instruction › Safety Orientation
Issued 21 July 2009 Resolved
Post emergency instructions.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 21 August 2009
Resolution: Items Posted.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 July 2009 Resolved
Provide watertight container & mark same for first aid kit.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Fire Fighting › Means of Escape › Emergency Lighting
Issued 21 July 2009 Resolved
Install portable light near eng room space.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Stability › Watertight Integrity › General
Issued 21 July 2009 Resolved
Double clamp all bilge pump hoses.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Documentation › Certificates/Documents › FCC SSL
Issued 21 July 2009 Resolved
Provide copy of FCC Certificates.
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 29 July 2009
Stability › Watertight Integrity › General
Issued 21 July 2009 Resolved
Provide suitable portable bilge pumps w/hoses.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Navigation › Piloting/Steering › Coast Guard Light List
Issued 21 May 2008 Resolved
Provide light list
Action required: 705 - Other - as specified
Due 21 June 2008
Resolved 25 August 2008
Resolution: O/O PROVIDED LIGHT LIST
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 21 May 2008 Resolved
Post emergency instructions
Action required: 705 - Other - as specified
Due 21 June 2008
Resolved 25 August 2008
Resolution: Emergency instructions posted in cabin
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 May 2008 Resolved
Install snap hook on ring bouy light lanyard
Action required: 705 - Other - as specified
Due 21 June 2008
Resolved 25 August 2008
Resolution: Snap hook installed
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 May 2008 Resolved
Replace expired first aid kit items
Action required: 705 - Other - as specified
Due 21 June 2008
Resolved 25 August 2008
Resolution: Expired first aid items replaced in kit
Communications › Radio Communications › VHF Radiotelephone
Issued 21 May 2008 Resolved
Provide FCC operators license
Action required: 705 - Other - as specified
Due 21 June 2008
Resolved 25 August 2008
Resolution: Operator has FCC operators permit
Communications › Radio Communications › EPIRB
Issued 21 May 2008 Resolved
Replace expired EPIRB hydrostatic release
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 25 August 2008
Resolution: New hydrostatic release installed on EPIRB
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 8 June 2007 Resolved
Complete annual servicing for all portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2007
Resolved 18 March 2008
Resolution: Rcvd copies of servicing tags.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 8 June 2007 Resolved
Complete annual servicing for fixed firefighting cylinder.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2007
Resolved 18 March 2008
Resolution: Rcvd copies of servicing tags.
Lifesaving › Hand Flares › Quantity
Issued 8 June 2007 Resolved
Provide three (03) additional red hand flares.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 18 March 2008
Resolution: Rcvd copy of receipt of new flares.
Fire Fighting › Fire Bucket › Availability
Issued 8 June 2007 Resolved
Provide 3 "dedicated" fire buckets, marked "FIRE BUCKET" (at least 2.5 gal ea.) with lanyards attached.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 18 March 2008
Resolution: Rcvd photo of fire buckets.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 8 June 2007 Resolved
Post Emergency Instructions (as outlined in 46CFR185.512).
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 18 March 2008
Resolution: Rcvd verification that emergency instructions were posted.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 7 June 2006 Resolved
Vessel is restricted to limited coastwise route until PFD lights installed on all PFDs.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 30 June 2006
Resolution: Issued amended COI to reflect a Coastwise route, so PFD lights are not required.
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 April 2006 Resolved
Prove proper indicator unit and label bilge pump location at console.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2006
Resolution: Tested SAT
Communications › Alarms/Indicators › High Water Alarm
Issued 21 April 2006 Resolved
Provide and label high water alarm indicators for each protected space, audible and visual.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2006
Stability › Watertight Integrity › General
Issued 21 April 2006 Resolved
Attach cable/chain to forward freeman hatch on WX deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 21 April 2006 Resolved
Mount and label 3 portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2006
Fire Fighting › Fire Bucket › Quantity
Issued 21 April 2006 Resolved
Add and label 3 fire buckets with lanyards to vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2006
Documentation › Markings/Placards › Warning Signs
Issued 21 April 2006 Resolved
Post emergency instructions (fire/AB ship/MOB) PFD donning, deviation table, and speed/wave height table.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2006
Documentation › Certificates/Documents › Stability Letter
Issued 21 April 2006 Resolved
Post stability letter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2006
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 21 April 2006 Resolved
Provide evidence of DOT approved random drug testing enrollment for all crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2006
Operations/Management › Drills/Instruction › Fire
Issued 21 April 2006 Resolved
Conduct fire/MOB/abandon ship drills in presence and to satisfaction of marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2006
Stability › Incline Test › General
Issued 21 April 2006 Resolved
Provide USCG MSC issued stability letter and post in cabin.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2006

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.