A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 June 2012
Resolved
Provide visual + audible bilge high level alarms for amidships and engine compartments.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2012
Resolution: High level alarms were in existence but the crew was unaware of such existence and therefore unable to test them. Once the crew became aware of alarm operation, a deficiency check was conducted during which time a successful test was completed.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 1 June 2012
Resolved
Affix proper hailing port on stern.
Due 15 June 2012
Resolved 17 July 2012
Resolution: Hailing port affixed.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 1 June 2012
Resolved
Vessel is restricted to the carriage of 20 total persons until 10 - person life raft is serviced and installed aboard the vessel.
Due 6 July 2012
Resolved 13 June 2012
Resolution: Satisfactorily inspected liferaft installation and certification.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 21 July 2009
Resolved
Install lights on all life jackets - vessel restricted limited coastwise & nearer routes until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 21 July 2009
Resolved
Mark life jacket stowage w/appropriate numbers.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Operations/Management › Drills/Instruction › Safety Orientation
Issued 21 July 2009
Resolved
Post appropriate life jacket donning instructions.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 10 August 2009
Stability › Watertight Integrity › General
Issued 21 July 2009
Resolved
Install securing devices to both eng. wx deck hatch covers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 July 2009
Resolved
Prove proper operation of fwd p/s bilge alarms.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 21 July 2009
Engineering › Fuel Oil Service System › Piping
Issued 21 July 2009
Resolved
Install bonding cables on p/s fuel fill lines.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 3 August 2009
Resolution: Received pictures showing bonding of P&S fuel tanks.
Fire Fighting › Ventilation Systems › Ducts
Issued 21 July 2009
Resolved
Make engine vents smoketight and prove proper operation of closing devices.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Fire Fighting › Fire Bucket › Availability
Issued 21 July 2009
Resolved
Provide 2 additional 2 1/2 gallon buckets w/lanyards mark same as fire buckets prior to operation w/pax.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 August 2009
Resolved 27 July 2009
Stability › Watertight Integrity › General
Issued 21 July 2009
Resolved
Install/replace missing securing device for port fwd hatch cover.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 21 July 2009
Resolved
Obtain & keep onboard current copy of COLREG.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 July 2009
Resolved
Post stability letter and COI.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 21 August 2009
Resolution: Items Posted.
Personnel › Training › First Aid/CPR
Issued 21 July 2009
Resolved
Provide proof of CPR/First aid training for crew.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 21 August 2009
Lifesaving › Hand Flares › Quantity
Issued 21 July 2009
Resolved
Provide 3 orange day smokes & 2 red hand flares.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Operations/Management › Drills/Instruction › Safety Orientation
Issued 21 July 2009
Resolved
Post emergency instructions.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 21 August 2009
Resolution: Items Posted.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 July 2009
Resolved
Provide watertight container & mark same for first aid kit.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Fire Fighting › Means of Escape › Emergency Lighting
Issued 21 July 2009
Resolved
Install portable light near eng room space.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Stability › Watertight Integrity › General
Issued 21 July 2009
Resolved
Double clamp all bilge pump hoses.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Documentation › Certificates/Documents › FCC SSL
Issued 21 July 2009
Resolved
Provide copy of FCC Certificates.
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 29 July 2009
Stability › Watertight Integrity › General
Issued 21 July 2009
Resolved
Provide suitable portable bilge pumps w/hoses.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 27 July 2009
Navigation › Piloting/Steering › Coast Guard Light List
Issued 21 May 2008
Resolved
Provide light list
Action required: 705 - Other - as specified
Due 21 June 2008
Resolved 25 August 2008
Resolution: O/O PROVIDED LIGHT LIST
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 21 May 2008
Resolved
Post emergency instructions
Action required: 705 - Other - as specified
Due 21 June 2008
Resolved 25 August 2008
Resolution: Emergency instructions posted in cabin
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 May 2008
Resolved
Install snap hook on ring bouy light lanyard
Action required: 705 - Other - as specified
Due 21 June 2008
Resolved 25 August 2008
Resolution: Snap hook installed
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 May 2008
Resolved
Replace expired first aid kit items
Action required: 705 - Other - as specified
Due 21 June 2008
Resolved 25 August 2008
Resolution: Expired first aid items replaced in kit
Communications › Radio Communications › VHF Radiotelephone
Issued 21 May 2008
Resolved
Provide FCC operators license
Action required: 705 - Other - as specified
Due 21 June 2008
Resolved 25 August 2008
Resolution: Operator has FCC operators permit
Communications › Radio Communications › EPIRB
Issued 21 May 2008
Resolved
Replace expired EPIRB hydrostatic release
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 25 August 2008
Resolution: New hydrostatic release installed on EPIRB
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 8 June 2007
Resolved
Complete annual servicing for all portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2007
Resolved 18 March 2008
Resolution: Rcvd copies of servicing tags.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 8 June 2007
Resolved
Complete annual servicing for fixed firefighting cylinder.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2007
Resolved 18 March 2008
Resolution: Rcvd copies of servicing tags.
Lifesaving › Hand Flares › Quantity
Issued 8 June 2007
Resolved
Provide three (03) additional red hand flares.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 18 March 2008
Resolution: Rcvd copy of receipt of new flares.
Fire Fighting › Fire Bucket › Availability
Issued 8 June 2007
Resolved
Provide 3 "dedicated" fire buckets, marked "FIRE BUCKET" (at least 2.5 gal ea.) with lanyards attached.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 18 March 2008
Resolution: Rcvd photo of fire buckets.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 8 June 2007
Resolved
Post Emergency Instructions (as outlined in 46CFR185.512).
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 18 March 2008
Resolution: Rcvd verification that emergency instructions were posted.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 7 June 2006
Resolved
Vessel is restricted to limited coastwise route until PFD lights installed on all PFDs.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 30 June 2006
Resolution: Issued amended COI to reflect a Coastwise route, so PFD lights are not required.
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 April 2006
Resolved
Prove proper indicator unit and label bilge pump location at console.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2006
Resolution: Tested SAT
Communications › Alarms/Indicators › High Water Alarm
Issued 21 April 2006
Resolved
Provide and label high water alarm indicators for each protected space, audible and visual.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2006
Stability › Watertight Integrity › General
Issued 21 April 2006
Resolved
Attach cable/chain to forward freeman hatch on WX deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 21 April 2006
Resolved
Mount and label 3 portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2006
Fire Fighting › Fire Bucket › Quantity
Issued 21 April 2006
Resolved
Add and label 3 fire buckets with lanyards to vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2006
Documentation › Markings/Placards › Warning Signs
Issued 21 April 2006
Resolved
Post emergency instructions (fire/AB ship/MOB) PFD donning, deviation table, and speed/wave height table.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2006
Documentation › Certificates/Documents › Stability Letter
Issued 21 April 2006
Resolved
Post stability letter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2006
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 21 April 2006
Resolved
Provide evidence of DOT approved random drug testing enrollment for all crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2006
Operations/Management › Drills/Instruction › Fire
Issued 21 April 2006
Resolved
Conduct fire/MOB/abandon ship drills in presence and to satisfaction of marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2006
Stability › Incline Test › General
Issued 21 April 2006
Resolved
Provide USCG MSC issued stability letter and post in cabin.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2006