Records from 2014 to 2018. Most recent: inspection, 11 October 2018.
Inspection history · 5
11 October 2018
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6559218
1 August 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6227188
1 August 2017
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6227257
16 May 2016
COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5884749
3 March 2016
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5826120
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 October 2018
Resolved
A vessel may not operate without having on board a valid U.S. Coast Guard Certificate of Inspection.
Vessel has exceeded their Annual Inspection date by more then 3 months as required in 46 CFR 176.500 (b) (1). Vessel is not to operate commercially; carry passengers or cargo; until they have an Annual Inspection completed by an attending U.S. Coast Guard Marine Inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2018
Resolved 6 December 2018
Resolution: Vessel rep surrendered COI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 October 2018
Resolved
Vessel owner or operator must pay the annual vessel inspection fees for each year on or before the vessel's user fee anniversary date.
Vessel has not paid 2018 user fees. An Annual Inspection will not be scheduled until associated fees have been paid. Vessel is not to operate commercially; carry passengers or cargo; until user fees are paid.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2018
Resolved 6 December 2018
Resolution: Vessel rep surrendered COI.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 August 2017
Resolved
Non Operational
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2017
Resolved 30 September 2017
Resolution: Owner sent picture verifying the function test of nav light.
Electrical › Electric Generation Source (service) › Panelboard
Issued 18 August 2017
Resolved
Hole in breaker name plate exposing interal wiring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2017
Resolved 18 August 2017
Resolution: Corrected Prior to departure.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 3 March 2016
Resolved
Master's license must be provided.
Action required: 705 - Other - as specified
Due 3 March 2016
Resolved 3 March 2016
Resolution: Master went home and returned with his valid license.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 3 March 2016
Resolved
Provide 01 adult lifejacket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2016
Resolution: Vessel provided lifejackets
Lifesaving › Hand Flares › Quantity
Issued 3 March 2016
Resolved
Provide 04 distress signals.
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 16 March 2016
Resolution: Vessel provided 04 distress signals.
Fire Fighting › Fire Bucket › Quantity
Issued 3 March 2016
Resolved
Provide 02 fire buckets.
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 16 March 2016
Resolution: 02 fire buckets were provided.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 3 March 2016
Resolved
Provide pollution prevention placard.
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 16 March 2016
Resolution: Placard was provided.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 3 March 2016
Resolved
Provide 02 flashlights (one at operating station, one for engine compartment).
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 16 March 2016
Resolution: Flashlight was provided at operating station and one for engine compartment
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 March 2016
Resolved
Provide waterlight lanyard and corrosion resistant clip.
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 16 March 2016
Resolution: Waterlight lanyard and corrosion resistant clip was provided.