MAURY USCG vessel records Sign in
← All vessels

DUCK 9

DUCK 9 is a 2006 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2006, most recently in April 2020, along with 13 deficiencies — 3 with no resolution recorded — and 1 operational control.

Records from 2006 to 2020. Most recent: inspection, 30 April 2020.

Built
2006
Last inspected
30 April 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

808241
Flag
UNITED STATES
—
Maury page id
psix-808241

Inspections, by type

…past their stated due date3
Years with a record 11 calendar years (2006–2020)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 16

30 April 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6946210
2 August 2019 Examination of Repairs · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6773665
12 July 2019 Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6744452
15 May 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6685212
5 March 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6636790
6 September 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6534416
28 February 2018 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6362869
29 March 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6155130
27 January 2016 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5795954
24 January 2012 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4232276
25 January 2010 Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3668439
25 March 2009 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3440213
24 January 2008 Internal Structural Exam · Drydock Exam · Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3136017
31 January 2007 Hull Examination · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2864702
24 April 2006 Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2632298
27 March 2006 Initial Certification · Internal Structural Exam · Construction Oversight · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2595519

Deficiency record · 13

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 May 2020 No resolution recorded
46CFR176.840/MSIB 15-20 / 701c - IN ACCORDANCE WITH MSIB 15-20, AN INSPECTION OF THE CANOPY AND SIDE CURTAINS, AND A STABILITY REVIEW MUST BE CONDUCTED PRIOR TO CARRYING PASSENGERS AND RECOMMENCING OPERATIONS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2020 — due date passed with no resolution recorded
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 9 May 2020 No resolution recorded
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2020 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 May 2020 No resolution recorded
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2020 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 August 2019 Resolved
46 CFR 176.814 / 17c - An inspection and test of steering systems on the following vessels, owned or operated by Ride the Ducks of Seattle, must be conducted to determine they are in suitable condition and fit for the service intended: DUCK 9 (CG808241), DUCK 12 (CG866032), DUCK 16 (CG1042941), DUCK 18 (CG1107015).
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2019
Resolved 3 August 2019
Resolution: Conducted inspection of steering cable using 30x magnifying glass, all sat. Cable installed on 26Feb2017. Conducted operational steering test, all sat.
Engineering › Fuel Oil Service System › Pump
Issued 25 January 2010 Resolved
Make proper repairs to Holley fuel pump, prior to operation IAW 46 CFR 176.830.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 January 2010
Resolved 2 February 2010
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 31 January 2007 Resolved
Prove proper operation of ventilation exhaust blower for bilge upon activation of fixed CO2.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 February 2007
Resolved 1 February 2007
Resolution: Installed blower to shutdown upon activation of fixed CO2.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 31 January 2007 Resolved
Prove electrically supervised fire/heat detection circuit
Action required: 705 - Other - as specified
Due 7 May 2007
Resolved 10 May 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 31 January 2007 Resolved
Prove proper operation of bilge alarm in engine compartment.
Action required: 705 - Other - as specified
Due 9 February 2007
Resolved 1 February 2007
Resolution: Replaced alarm float. Test sat.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 27 March 2006 Resolved
Properly stencil vessels name onto each life jacket.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 April 2006
Resolved 26 April 2006
Resolution: Type 1 Lifejackets properly marked
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 27 March 2006 Resolved
Properly stencil vessels name onto both life ring buoys.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 April 2006
Resolved 26 April 2006
Resolution: Lifebuoys properly marked.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 27 March 2006 Resolved
Properly stencil vessels name onto the hull.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 April 2006
Resolved 26 April 2006
Resolution: Vessel name properly marked on hull.
Personnel › Training › Familiarization Training
Issued 27 March 2006 Resolved
Properly conduct emergency drill & training with vessel's proposed master.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2006
Resolved 26 April 2006
Resolution: Satisfactory conducted emergency drill.
Construction/Loadline › Structures › Door
Issued 27 March 2006 Resolved
Properly repair minor water leak on the stbd side passenger door.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 April 2006
Resolved 26 April 2006
Resolution: No water leakage visible on passenger side door.

Ownership record