Records from 2005 to 2026. Most recent: inspection, 3 March 2026.
Documentation record
Registered dimensions (L × B × D)82.2 ft × 20.0 ft × 6.0 ft
Registered tonnagegross 83 / net 56
ITC dimensions (L × B × D)82.2 ft × 20.0 ft × 6.0 ft
ITC tonnagegross 178 / net 63
BuilderMID-CITY STEEL FABRICATING, INC. · LA CROSSE, WI, UNITED STATES · built 2006
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKNOXVILLE, TN
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 24 October 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it83 - Regulatory (Subpart C or D), Gross Ton
178 - Convention (Subpart B), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
63 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
3 March 2026
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 8319667
10 February 2026
COI Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 8308119
21 May 2025
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 8142278
17 May 2023
Annual Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7691978
5 April 2022
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7425835
23 March 2021
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7170229
25 January 2021
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7128339
25 July 2019
DAPI Audit · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6767319
18 July 2018
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6495209
18 July 2017
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6223365
30 March 2016
Drydock Exam · DAPI Audit · COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 5862047
12 June 2014
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4890197
18 October 2010
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3919693
14 May 2008
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3192249
15 May 2007
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2936524
11 May 2006
Deficiency Check · Initial Certification
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2644983
17 September 2005
Construction Oversight
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2626382
Engineering › Bilge Water Management System › Not Operational
Issued 26 April 2016
Resolved
Switch broken in engine room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 26 April 2016
Resolution: Replaced switch
Lifesaving › Lifefloat › Serviceable
Issued 12 June 2014
Resolved
Vessel is not required to maintain or have onboard lifefloats located on top of wheel house. Remove all lifefloats and the associated equipment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 11 July 2014
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 June 2014
Resolved
Replace all navigation lights with approved marine grade bulbs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 17 June 2014
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 May 2007
Resolved
Provide 4 additional adult sized type I PFD's. Passenger count is reduced by 4 until corrected.
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 14 May 2008
Resolution: All PFD''s are present.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 11 May 2006
Resolved
Post PFD donning placards where they will be visible to passengers.
Action required: 705 - Other - as specified
Due 11 June 2006
Resolved 15 June 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 May 2006
Resolved
Renew line for water light on aft deck ring buoy with proper type and length and install clip to enable quick release.
Action required: 705 - Other - as specified
Due 11 June 2006
Resolved 15 June 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 11 May 2006
Resolved
Reposition B-II portable fire extinguisher in galley.
Action required: 705 - Other - as specified
Due 11 June 2006
Resolved 15 June 2006
Construction/Loadline › Hull › Side Shell
Issued 11 May 2006
Resolved
Install cap on 2" pipe penetration on starboard side of engine room.
Action required: 705 - Other - as specified
Due 11 June 2006
Resolved 15 June 2006
Stability › Watertight Integrity › General
Issued 11 May 2006
Resolved
Install retaining device on hatch cover for lazarette.
Action required: 705 - Other - as specified
Due 11 June 2006
Resolved 15 June 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 11 May 2006
Resolved
Replace nylon heaving line on forward ring buoy with buoyant line.
Action required: 705 - Other - as specified
Due 11 June 2006
Resolved 15 June 2006
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 11 May 2006
Resolved
Extend rescue platform to water or provide alternative means to retrieve a person from the water.
Action required: 705 - Other - as specified
Due 11 June 2006
Resolved 15 June 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 May 2006
Resolved
Install proper wire connectors on terminal block behind door at right of helm.
Action required: 705 - Other - as specified
Due 11 June 2006
Resolved 15 June 2006
Electrical › Electric Generation Source (service) › Generator
Issued 11 May 2006
Resolved
Troubleshoot and repair main generator.
Action required: 705 - Other - as specified
Due 11 June 2006
Resolved 15 June 2006
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 11 May 2006
Resolved
Provide 20 additional adult PFDs. Passenger capacity reduced by 20 until item is corrected.
Action required: 705 - Other - as specified
Due 11 June 2006
Resolved 15 June 2006