MAURY USCG vessel records
← All vessels

SEA LION

SEA LION is a 2006 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in April 2026, along with 6 deficiencies and 1 casualty investigation in 2009.

Records from 2009 to 2026. Most recent: inspection, 15 April 2026.

Built
2006
Last inspected
15 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC9437
809450
Flag
UNITED STATES
Maury page id
psix-809450

Documentation record

Registered dimensions (L × B × D)55.0 ft × 15.7 ft × 8.0 ft
Registered tonnagegross 46 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFIBERCRAFT INC · BLAINE, WA, UNITED STATES · built 2006
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portFRIDAY HARBOR, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 4 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46 - Simplified, Gross Ton
37 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

17 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

15 April 2026 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8333972
26 January 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8296474
19 March 2025 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8101333
8 March 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7883214
31 January 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7859450
16 March 2023 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7650405
22 March 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7418201
14 January 2022 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7380678
17 March 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7158950
16 March 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6926345
24 January 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6894281
19 March 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6643168
21 February 2018 COI Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6359110
29 January 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6342147
24 February 2017 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6101482
11 March 2016 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5833995
22 January 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5800446

Deficiency record · 6

02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 January 2026 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. Stringer in engine room has a significant crack in the gelcoat and possibly top layer of laminate. Vessel is to renew damaged fiberglass and gelcoat for joint of this stringer to the longitudinal. 46 CFR 176.802(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2026
Resolved 18 February 2026
Resolution: Damaged fiberglass has been repaired and repainted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 January 2026 Resolved
All cable and wire must: be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. Vessel is to renew all plastic ties support electrical wires and cables with metal supports.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2026
Resolved 18 February 2026
Resolution: Metal supports have been installed in "the garage".
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 26 January 2026 Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction. Vessel is to renew port and starboard deck rails support to original strength.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2026
Resolved 18 February 2026
Resolution: Rails have been reinstalled.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 January 2026 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. Vessel is to seal interior hull in area surrounding sewage tank vent to saturation of vessel core from excessive interior condensation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2026
Resolved 18 February 2026
Resolution: Satisfactory sealant applied around vent overboard.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Approval
Issued 28 February 2018 Resolved
Fire extinguisher at operating station not appropriate type/size. Replace extinguisher with 10-B:C or greater prior to carriage of passengers. 46 CFR 181.500
Action required: 705 - Other - as specified
Due 1 March 2018
Resolved 1 March 2018
Resolution: Installed 40-B:C extinguisher at operating station.
Lifesaving › Lifefloat › Serviceable
Issued 28 February 2018 Resolved
Lifefloats not in good working order. Replace in-kind. 46 CFR 185.700
Action required: 705 - Other - as specified
Due 27 March 2018
Resolved 22 March 2018
Resolution: Replaced Lifefloat with IBA.

Casualty record · 1

29 September 2009Routine · role: Transiting Vicinity of Primary Subject · activity 3606855
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.