Records from 1995 to 2005. Most recent: inspection, 25 April 2005.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
25 April 2005
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2342463
30 March 2005
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2323216
11 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1964232
4 March 2002
Re-Inspection · Hull Examination · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1489849
12 February 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1062711
2 February 2001
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1376436
30 March 2000
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 816738
13 March 2000
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1451519
18 January 2000
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 814527
16 December 1999
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1430783
6 December 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1442920
26 March 1999
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1406465
11 February 1999
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1369033
4 February 1998
Plan Review "T" Boat · Hull Examination · Deficiency Check · MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1411618
5 April 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1360061
Construction/Loadline › Structures
Issued 4 March 2002
Resolved
Repair cracks in main deck, at the corners, forward of the pilothouse on both the port and stbd sides in accordance with 46 CFR 176.610. LEGACY COMPONENT DESC: Main Deck
Due 14 March 2002
Resolved 7 March 2002
Resolution: Vessel operator had the cracks ground and rewelded.
Navigation › Piloting/Steering
Issued 4 March 2002
Resolved
Provide Coast Guard Light List in accordance with 46 CFR 184.420. LEGACY COMPONENT DESC: Coast Guard Light List
Due 14 March 2002
Resolved 7 March 2002
Resolution: Vessel operator provided a copy of the Coast Guard Light List.
Lifesaving › Lifejacket/PFD (Type III)
Issued 4 March 2002
Resolved
Remove "M/V ANNA, New Orleans" from adult life jackets in accordance with 46 CFR 185.604(b). LEGACY COMPONENT DESC: Marking
Due 14 March 2002
Resolved 7 March 2002
Resolution: Vessel operator blacken out the name "M/V ANNA, New Orleans" from the adult life jackets.
Engineering
Issued 4 March 2002
Resolved
Prove proper operation of the bilge high level alarms in accordance with 46 CFR 182.530. LEGACY COMPONENT DESC: Bilge High Level Alarms
Due 14 March 2002
Resolved 13 March 2002
Resolution: Vessel operator proved proper operation of bilge high level alarms.
Engineering
Issued 4 March 2002
Resolved
Provide portable bilge pump (5 GPM) in accordance with 46 CFR 182.520(b). LEGACY COMPONENT DESC: Portable Bilge Pump
Due 14 March 2002
Resolved 13 March 2002
Resolution: Vessel operator provided portable ligle pump (5 GPM).
Construction/Loadline
Issued 2 February 2001
Resolved
Replace all safety chain locking devices on deck rails in accordance with 46 CFR 177.900.
Condition: Unknown
Due 9 February 2001
Resolved 13 February 2001
Lifesaving
Issued 2 February 2001
Resolved
Replace expired EPIRB hydrostatic release unit in accordance with 46 CFR 185.728.
Condition: Unknown
Due 9 February 2001
Resolved 13 February 2001
Accommodation/Occupational Safety
Issued 2 February 2001
Resolved
Prove proper operation of toilet facility in accordance with 46 CFR 184.704.
Condition: Unknown
Due 9 February 2001
Resolved 20 February 2001
Electrical
Issued 2 February 2001
Resolved
Remove wiring for lighting from port and starboard natural supply vent ducting for engineroom in accordance with 46 CFR 183.340.
Condition: Unknown
Due 9 February 2001
Resolved 20 February 2001
Accommodation/Occupational Safety
Issued 2 February 2001
Resolved
Clean out toilet facility in accordance with 46 CFR 176.818.
Condition: Unknown
Due 9 February 2001
Resolved 13 February 2001
Construction/Loadline
Issued 13 March 2000
Resolved
Ensure forward bulkhead to tank space is watertight. Ensure all holes/protrusions are properly sealed. IAW: 46 CFR 171.114.
Condition: Unknown
Due 30 March 2000
Resolved 30 March 2000
Electrical
Issued 13 March 2000
Resolved
Replace melted light cover (over port main diesel engine). IAW: 46 CFR 183.410.
Condition: Unknown
Due 30 March 2000
Resolved 30 March 2000
Construction/Loadline
Issued 13 March 2000
Resolved
Repair cracked/unsatisfactory aluminum welds in the following locations: Engine space, #2 & #3 main transverse frames (near overhead, port/stbd sides). Forward bow compartment, #2 & #3 main transverse frames (near overhead, stbd side). IAW: 46 CFR 176.00 (2) (d), 176.800.
Condition: Unknown
Due 30 March 2000
Resolved 30 March 2000
Electrical
Issued 13 March 2000
Resolved
Repair/remove dead end electrical wires in forward bow space. IAW: 46 CFR 183.340 (3) (G).
Condition: Unknown
Due 30 March 2000
Resolved 30 March 2000
Deck/Cargo
Issued 16 December 1999
Resolved
Remove or repair forward deck winch iaw 46 CFR 176.802.
Condition: Unknown
Due 16 December 1999
Resolved 16 December 1999
Engineering
Issued 6 December 1999
Resolved
Prove proper operation of engines iaw 46 CFR 176.30-1.
Condition: Unknown
Due 6 December 1999
Resolved 6 December 1999
Electrical
Issued 6 December 1999
Resolved
Install approved marine grade wiring on exterior PA speakers iaw 46CFR183.05-50.
Condition: Unknown
Due 6 December 1999
Resolved 6 December 1999
Electrical
Issued 6 December 1999
Resolved
Properly wire masthead light iaw 46 CFR 183.420.
Condition: Unknown
Due 6 December 1999
Resolved 6 December 1999
Navigation
Issued 6 December 1999
Resolved
Prove proper operation of navigation lights iaw 46 CFR 183.420
Condition: Unknown
Due 6 December 1999
Resolved 6 December 1999
Electrical
Issued 6 December 1999
Resolved
Properly wire port and stbd aft deck lighting iaw 46 CFR 183.05-50 (a)(2).
Condition: Unknown
Due 6 December 1999
Resolved 6 December 1999
Engineering
Issued 6 December 1999
Resolved
Remove portable fans or install permanent ventilation fans, found in port_x001C_ and stbd engine compartments iaw 46 CFR 182.20-45.
Condition: Unknown
Due 6 December 1999
Resolved 6 December 1999
Engineering
Issued 6 December 1999
Resolved
Prove vent fans comply to UL standards iaw 46 CFR 183.05-35.
Condition: Unknown
Due 6 December 1999
Resolved 6 December 1999
Lifesaving
Issued 6 December 1999
Resolved
Repair inop waterlight for ring buoy iaw 46 CFR 180.70 d.
Condition: Unknown
Due 6 December 1999
Resolved 6 December 1999
Engineering
Issued 6 December 1999
Resolved
Install rigid, permanent, fireproof ducting on all supply and exhaust ventilation ducts iaw 46 CFR 182.20-45d.
Condition: Unknown
Due 6 December 1999
Resolved 6 December 1999
Lifesaving
Issued 6 December 1999
Resolved
Mark both lifefloats, ring life buoy, and paddles iaw 46 CFR 185.604.
Condition: Unknown
Due 6 December 1999
Resolved 6 December 1999
Navigation
Issued 26 March 1999
Resolved
Repair/replace radar to an operational condition IAW 46CFR184.404.
Condition: Unknown
Due 3 April 1999
Resolved 31 March 1999
Lifesaving
Issued 11 February 1999
Resolved
Attach Life Float paddles to Life Float IAW 46 CFR 180.175(f)(2).
Condition: Unknown
Due 11 February 1999
Resolved 11 February 1999
Electrical
Issued 11 February 1999
Resolved
Properly dead-end or remove improperly dead-ended electrical cable at control console, centerline, deck level in pilot house.
Condition: Unknown
Due 11 February 1999
Resolved 11 February 1999
Engineering
Issued 11 February 1999
Resolved
Install insulation at exhaust flange joints on #2 MDE IAW 46 CFR 182.430(a).
Condition: Unknown
Due 11 February 1999
Resolved 11 February 1999
Construction/Loadline
Issued 11 February 1999
Resolved
Attach lazarette hatch cover to hull IAW 46 CFR 179.360(b)(2).
Condition: Unknown
Due 11 February 1999
Resolved 11 February 1999
Navigation
Issued 11 February 1999
Resolved
Repair starboard running light mount welds.
Condition: Unknown
Due 11 February 1999
Resolved 11 February 1999
Electrical
Issued 4 February 1998
Resolved
Install a switch cover plate on the air compressor switch box.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Electrical
Issued 4 February 1998
Resolved
Tighten the generator cable box connector at the generator terminal connection box.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Electrical
Issued 4 February 1998
Resolved
Support all wiring at 24 inch intervals using metal cable supports throughout the vessel.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Electrical
Issued 4 February 1998
Resolved
Remove dead-end cable sections and unacceptable splice in the port forward compartment.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Electrical
Issued 4 February 1998
Resolved
Remove SO cable used in the anchor winch electrical system. Use acceptablecable for permanent electrical installations. Mount the winch motor controller box.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Electrical
Issued 4 February 1998
Resolved
Bond all 120VAC braided armor cable to the metal hull at both ends.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Electrical
Issued 4 February 1998
Resolved
Insulate the generator exhaust system up to the point of water injection.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Navigation
Issued 4 February 1998
Resolved
Clean or replace the mast head light lens to increase luminance to Navigation Regulations specifications.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Navigation
Issued 4 February 1998
Resolved
Effect repairs to the anchor light.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Electrical
Issued 4 February 1998
Resolved
Provide frequency, voltage, and amperage meters for the service diesel generator per 46 CFR 183.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Accommodation/Occupational Safety
Issued 4 February 1998
Resolved
Provide a second chain in railing in way of passenger access openings.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Lifesaving
Issued 4 February 1998
Resolved
Post PFD donning instructions.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Lifesaving
Issued 4 February 1998
Resolved
Post a radio distress placard.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Navigation
Issued 4 February 1998
Resolved
Provide an FCC Radio Safety Certificate.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998