MAURY USCG vessel records
← All vessels

BBC AFRICA

BBC AFRICA is a 2006 freight ship. The Coast Guard has recorded 31 inspections since 2017, most recently in May 2026, along with 25 deficiencies and 8 operational controls.

Records from 2017 to 2026. Most recent: inspection, 24 May 2026.

Built
2006
Last inspected
24 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 May 2026
…with no type recorded10
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9362621
809829
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-809829

Documentation record

Tonnage as PSIX records it7530 - Dead Weight, Ton
6765 - Displacement, Ton
7002 - Convention (Subpart B), Gross Ton
3375 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

COMMON FAITH Freight Ship · MISLE 1172121 · 25 August 2023 · activity 7776851

Inspection history · 31

24 May 2026 Administrative Inspection · PSC B · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8376696
11 December 2025 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8275369
3 March 2024 PSC B · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7873790
19 February 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7867179
9 February 2024 ISM Exam · PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7860642
9 February 2024 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7863696
26 January 2024 PSC B · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7856022
9 January 2024 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7846948
22 December 2023 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7864963
7 September 2023 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7786693
25 August 2023 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7776851
20 June 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7718910
26 May 2023 Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7696887
20 September 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7316453
20 September 2021 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7316524
7 July 2020 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6992341
2 July 2019 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6727212
2 July 2019 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6745732
25 June 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6732496
24 May 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6686436
16 September 2018 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6541479
28 July 2018 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6492945
27 July 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6491566
26 July 2018 COE-Offshore
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6491585
5 February 2018 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6349484
7 November 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6300398
7 November 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6302804
7 November 2017 ISPS III Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6302982
25 March 2017 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6110984
20 March 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6114187
4 January 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6065741

Deficiency record · 25

11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 24 May 2026 Resolved
74SOLAS(20)III/14.1 Rescue Boats shall be stowed in a state of continuous readiness for launching in not more than 5 minutes, and if the inflatable type, in a fully inflated condition at all times. PSCO observed that the vessel's rescue boat motor is not operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2026
Resolution: Class survey report attesting to rescue boat motor repairs received. Survey report is uploaded in Documents.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 December 2025 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL PRESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP. PSCO OBSERVED PORT SIDE ANCHOR'S INABILITY TO BE FULLY RAISED TO THE SHIP. 74 SOLAS (24) I/11.A ACTION: 15 AC
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 11 December 2025
Resolved 15 December 2025
Resolution: Class report well received.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 11 December 2025 Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED OIL SOAKED LAGGING ON HEATING OIL PIPING FOR THE BOILER. 74 SOLAS (04) II-2/4.1.1 ACTION: 15 AC
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 11 December 2025
Resolved 15 December 2025
Resolution: Class report well received.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 9 February 2024 Resolved
After any survey of the ship under article 14 has been completed, no change shall be made in the structure, equipment, arrangements, material, or scantlings covered by this survey, without sanction of the administration. Crew discovered crack in hull at STBD frame 30-31 on22DEC2023 and notified company on the same day. On 28DEC2023 the company arranged to have a temporary concrete patch applied over the observed crack. PSCO observed concrete patch to be leaking sea water into the engine room. Vessel completed additional temporary repairs to the satisfaction of the attending Class surveyor. Permanent repairs remain outstanding and must be completed to the satisfaction of the attending Class surveyor, and the Coast Guard. ICLL (88 Proto) Article 15 15 A,C
Action required: 15 - Rectify deficiencies by next port
Due 19 February 2024
Resolved 6 March 2024
Resolution: See class report. In addition, conducted PSC B to verify.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 9 February 2024 Resolved
After any survey of the ship under article 14 has been completed, no change shall be made in the structure, equipment, arrangements, material, or scantlings covered by this survey, without sanction of the administration. The company continued to operate the vessel without making permanent repairs to a 5-foot fracture in the starboard side shell of the engine room below the waterline and lower deck plates since 22 Dec 2023. Vessel Captain confirmed that the installed temporary concrete patch allowed the ingress of water at 100 liters per hour. The company failed to notify and receive authorization for temporary repairs from class or administration, despite a class survey of the vessel on 26 Jan 2024. The company and vessel failed to notify the port state, U.S. Coast Guard, over four U.S. port calls including a port state control examination completed in Houston, TX. International Load Line Certificate invalidated due to alterations made after survey with no approvals from class or administration. ICLL (88 Protocol) Article 15 30 A,C
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 17 February 2024
Resolution: See class documentation
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 9 February 2024 Resolved
3. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements, the company should ensure that: a non-conformity is reported. After discovery of a 5-foot crack in the side of the vessel the company failed to report the structural failure to class. Recommend external audit. 74 SOLAS (20) IX/3.1 ISM CODE PART A/10.2.2 30 A,C
Action required: 30 - Ship detained
Resolved 17 February 2024
Resolution: See class documentation
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 February 2024 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed multiple oil leaks on generators 1, 2, and 3, including multiple oil-soaked rags creating additional fire hazards. 74 SOLAS (20) II-2/4.1.1 30AC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 17 February 2024
Resolution: See class documentation
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 9 February 2024 Resolved
5. Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed A fire hose station and fire extinguisher inaccessible due to storage of boxes impeding access to the fire-fighting equipment. Additionally, the PSCO observed portable fire extinguisher #28 was missing a pin and the nozzle bracket was detached from the extinguisher. PSCO could not verify the extinguisher was in good working order. 74 SOLAS (20) II-2/ 14.2.1.2 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2024
Resolution: Vessel crew removed obstructions to fire hose station and replaced fire pin in extenguisher to attending inspector and class satisfaction.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 February 2024 Resolved
Escape routes shall be maintained in a safe condition, clear of obstacles. PSCO observed an escape trunk access hatch blocked by boxes rendering it inaccessible in an emergency. 74 SOLAS (20) II-2/12.1.2 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2024
Resolution: Vessel crew removed obstructions to escape trunk to attending inspector and class satisfaction.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 January 2024 Resolved
FIRE FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. PSCO OBSERVED ONE FIRE SUIT HELMET WITH A BROKEN VISOR AND AN ADDITIONAL HELMET MISSING FLASH HOOD/NECK COVERING.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2024
Resolution: Received report from class attesting that the broken visor was replaced with ship's spare and the neck covering was re-attached.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 January 2024 Resolved
THE FOLLOWING FIRE PROTECTION SYSTEMS SHALL BE KEPT IN GOOD ORDER SO AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS: STRUCTURAL FIRE PROTECTION, INCLUDING FIRE-RESISTING DIVISIONS AND PROTECTION OF OPENINGS AND PENETRATIONS IN THESE DIVISIONS. PSCO OBSERVED FIRE BOUNDARY DOORS IN LAUNDRY, A/C ROOM, AND THE WORK SHOP TO E/R STORES DOOR MARKED AS SELF-CLOSING ON FIRE CONTROL PLAN, BUT MISSING SELF-CLOSING DEVICES. ADDITIONALLY FOUND THE A-0 DOOR LEADING FROM WATER CLOSET TO MAIN STAIRWELL MISSING SELF-CLOSING DEVICE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2024
Resolution: Received report from class attesting that missing self-closing devices have been installed on all identified doors.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 January 2024 Resolved
DOORS REQUIRED TO BE SELF-CLOSING SHALL NOT BE FITTED WITH HOLD-BACK HOOKS. PSCO OBSERVED HOLD-BACK DEVICES ON THE FOLLOWING DOORS: DRY STORES, FWD A CLASS DOOR IN GEN SPACE, AND PAINT LOCKER.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2024
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 26 January 2024 Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed deck in the escape hatch buckled upward and cracking around the perimeter and centerline.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 January 2024
Resolution: Received attestation from class that surveyor checked the mentioned deck and found that the concrete heat insulation with minimal cracks are acceptable. The insulation is still intact and serves its purpose. The cracks do not cause any tripping hazard.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 26 January 2024 Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed starboard side platform near cargo hold two to have a broken weld, no longer supporting the deck grating.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 January 2024
Resolution: Received report from class attesting that deck fitter completed satisfactory repairs of broken weld.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 26 January 2024 Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed flame screens on the aft bulkhead in cargo hold 1, seperating cargo hold from the fwd fuel tank void space, containing tears and holes.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 January 2024
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 26 January 2024 Resolved
IF THE INSTALLED BWMS REQUIRED BY THIS SUBPART STOPS OPERATING PROPERLY, THE PERSON DIRECTING THE MOVEMENT OF THE VESSEL MUST ENSURE THAT THE PROBLEM IS REPORTED TO THE NEAREST CAPTAIN OF THE PORT AS SOON AS PRACTICABLE. PSCO OBSERVED INOPERABLE BWMS. FLAG STATE DISPENSATION STATES VESSEL MUST REPORT TO COASTAL STATES PRIOR TO ARRIVAL SECTOR HOUSTON RECIEVED NO PRIOR COMMUNICATION REGARDING BWMS.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 26 January 2024
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 7 September 2023 Resolved
15106 - Shipboard operations - The company should establish procedures plans, and instructions, including checklists as appropriate for key sipboard operations concerning the safety of the personnel, ship, and protection of the environment. safety management system manual does not address fire-fighting equipment maintenance, tests, or inspections to include high pressure CO2, portable extinguishers, foam applicators, ect. In addition, enclosed space entry procedures were vague regarding entry permits and air monitoring, as demonstrated by crew. Recommend internal audit be conducted within 90 days.74Solas(20)IX/6 ISM Code 7
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 January 2024
Resolved 9 January 2024
Resolution: Received internal audit attesting to satisfactory rectification.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 7 September 2023 Resolved
14503 - Garbage management plan - Every ship of 100 gross tonnage and above, and every ship which is certified to carry 15 or more persons, and or floating platforms shall carry a garbage managment plan which the crew shall follow. While in Houston for 14 days, garbage was stored in refer to combat decomposition. Garbage managment plan does not indicate this as an approved storage location.MARPOL Annex V/10.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 January 2024
Resolution: Received internal report of satisfactory rectification.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 7 September 2023 Resolved
09113 - Access/structure - No change shall be made in the structural arrangments, machinery, equipment, and other items covered by the survey, without the sanction of the administration. PSCO observed a portable reefer strapepd to a mooring winch fluid tank in the main deck passageway.74SOLAS(04)1/11
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 January 2024
Resolution: Received internal report of satisfactory rectification.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 7 September 2023 Resolved
13103 - Gauges, ect. - The condition of the ship and its equipment shall be maintained to conform to with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed tp sea without danger to the ship of persons on board. PSCO observed 2 broken gauges and 1 missing gauge for the main engine jacket cooling pumps. PSCO also observed temporary patches on the freshwater pipeline above the cargo hold bilge pump.74SOLAS(20)1/11
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 January 2024
Resolution: Received internal report of satisfactory rectification.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 September 2023 Resolved
09209 - Electrical - Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. PSCO identified broken ground strap on crane winch motor and exposed wire on incinerator.74SOLAS(04)II-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 September 2023
Resolution: Grounding strap was reattached and exposed wire corrected according to manufacture specifications.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 September 2023 Resolved
07124 - Maintenance of fire protection systems - Fire fighting systems and appliances shall be in good working order and available for imediate use. PSCO observed a hose for a foam applicator in the upper engine room with a hole, a ratchet strap impeding a firehose box near the incinerator from opening properly, and a portable extinguisher with extreme wear on deck.74SOLAS(04)II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 September 2023
Resolution: Hose was replaced in-kind, ratchet strap removed, and portable exinguisher replaced.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 September 2023 Resolved
Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gas-tight and self closing. PSCO observed 2 self closing A class doors to upper engine room unable to close properly as well as the A class self closing door to the emergency diesel generator space.74SOLAS(04)II-2/9.4.2.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 September 2023
Resolution: Doors were adjusted by crew and verfied to properly close by CG.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 May 2019 Resolved
07103- DIVISIONS-DECKS,BULKHEADS AND PENETRATIONS- WHERE "A" CLASS DIVISIONS ARE PENETRATED, SUCH PENETRATIONS SHALL BE SUITABLY INSULATED BY EXTENSION OF THE INSULATION AT THE SAME LEVEL OF THE DIVISION. PIPING PENETRATION INTO AUX ENGINE ROOM AND WORK SHOP, BOTH "A" BOUNDARY DIVISIONS, DO NOT HAVE CLASS APPROVED INSULATION INSTALLED. 74SOLAS(09)II-2/9.3.1- 50AC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2019
Resolved 25 June 2019
Resolution: Vessel was supplied with Class A and B sealing compound (Cert. No.: TAF00000T7) and missing boundary insulations were installed by crew, now inspected and found satisfactory
Engineering › Generator (propulsion-electric) › Battery
Issued 4 January 2017 Resolved
SEE NARRATIVE DEF #1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 April 2017
Resolved 20 March 2017
Resolution: Vessel provided Class Report stating starting arrangements for Emergency Generator were satisfactory.

Ownership record