Records from 2012 to 2026. Most recent: inspection, 22 April 2026.
Documentation record
Registered dimensions (L × B × D)147.5 ft × 29.5 ft × 10.8 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)147.5 ft × 29.5 ft × 10.8 ft
ITC tonnagegross 341 / net 102
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 2006
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 November 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
341 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
102 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 17 March 2025
Resolved
A hinged watertight bulkhead door must be fitted with a quick action closing devise operable from both sides of the door and indicator lights at the operating station. Engine room indicator light was burnt out.
46 CFR 179.330
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2025
Resolution: USCG inspected satisfactory repair.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 17 March 2025
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. No guard was around fuel transfer pump.
46 CFR 177.960
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2025
Resolution: USCG inspected satisfactory repair.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 17 March 2025
Resolved
The engine head, block, and exhaust manifold must be water-jacketed and cooled by water from a pump that operates whenever the engine is operating. Marine Inspectors identified two cooling water lines actively leaking and cooling piping with multiple temp repairs made to the system. Vessel is to effect temp repairs for the active leaking and preform permanent repairs prior to credit dry dock.
46 CFR 182.420
Action required: 705 - Other - as specified
Resolved 22 April 2026
Resolution: Prior to next topside exam.
Topside noted no leakage, all sat.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 17 March 2025
Resolved
fuel lines must be accessible, protected from mechanical
injury, and effectively secured against excessive
movement. Unsecured fuel line on fire monitor engine.
46 CFR 182.455
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2025
Resolution: USCG inspected satisfactory repair.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 17 March 2025
Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Aft part of the vessel had two courses of chains unsecured.
46 CFR 177.900
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2025
Resolution: USCG inspected satisfactory repair.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 17 March 2025
Resolved
Standby vessels must have, at least, the following equipment: For vessels certificated under sub chapters I or T of 46 CFR chapter I, a line throwing appliance that meets the requirements of 46 CFR 94.45. Vessel had three of four required canisters.
46 CFR 143.405
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2025
Resolution: USCG inspected satisfactory repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards. Line control distribution box had open contacts.
46 CFR 183.200
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2025
Resolution: USCG inspected satisfactory repair.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 March 2025
Resolved
A life float needs to be —Approved under approval series 160.027 or other standard specified by the Commandant. One 25 man life float identified needing repairs to grab lines and netting.
46 CFR 180.200 (2)
Action required: 705 - Other - as specified
Resolved 18 March 2025
Resolution: USCG inspected satisfactory repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 March 2024
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The vessel had a hose on the vent draining into the containment. Repair/replace as original.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2024
Resolved 29 March 2024
Resolution: Flame arrester was fitted to the outlet of the vent.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 March 2024
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. 02 life floats were found to have holes or cracks. Replace/repair as original. Manning is reduced to 37 people until resolved.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2024
Resolved 5 April 2024
Resolution: Vessel replaced life floats with new ones.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 March 2024
Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard. Vessel logs did not have record of this training being completed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2024
Resolved 29 March 2024
Resolution: Vessels logs were being kept with detailed drills/training.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 March 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. #1 MDE Turbocharger was leaking oil, #1 MDE wet exhaust missing clamps, and #2 MDE jacket water elbow was temp repaired to stop loss of coolant.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2024
Resolved 29 March 2024
Resolution: #1 MDE turbocharger seal replaced, #1 MDE wet exhaust clamps were replaced, and #2 jacket water pipe was cropped and renewed as original.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 March 2023
Resolved
02 Battery chargers in aft. Engine room have exposed terminals. Electrical equipment on a vessel must be installed to protect passengers and crew from electrical shock.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2023
Resolved 6 March 2023
Resolution: Third Party placed covers on the battery charges.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 6 March 2023
Resolved
Cable penetrating from engine room forward is not watertight. Penetrations in watertight bulkhead must be watertight.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2023
Resolved 6 March 2023
Resolution: Third Party placed firestop to seal the watertight penetrations.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 6 March 2023
Resolved
Fire detector system is not connected to fire panel in vessels passenger and crew spaces. I.e. Crew berthing, Galley, and bridge. Interconnected detectors and alarm systems must be installed in all areas IAW 46CFR181.405 and 46CFR118.400
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2023
Resolved 20 April 2023
Resolution: Vessel rep provided objective evidence via pictures and TPO Fire service report from email that shows fire detection system installed in crew and passinger accomidations.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 March 2023
Resolved
CO2 space markings missing from all entry doors into protected spaces and CO2 storage space. Spaces protected by CO2 must be conspicuously marked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2023
Resolved 7 March 2023
Resolution: Placards were placed onto the door as required. Photos sent.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 6 March 2023
Resolved
FCC radio operator permit required for every watch. When the operator is on duty and in-charge of transmitting systems, the license or permit document shall be displayed. One Captain did not have FCC radio license. 47CFR13.19(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2023
Resolved 27 March 2023
Resolution: Mate took FCC Radio course and vessel rep forwarded proof of certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 March 2023
Resolved
Pressure gauge on UPV’s did not meet requirement by being to low. The gauge shall be within 1.2 to 2 times the PSI which the reliving device is set to
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2023
Resolved 7 March 2023
Resolution: Vessel replaced guages with 300 PSI.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 March 2023
Resolved
03 Raycor filters, Flash Pans had left over fuel inside from maintenance work prior. All machinery and equipment must be installed to protect against fire, explosion, and machinery failure.
Action required: 10 - Deficiency Rectified
Due 6 March 2023
Resolved 6 March 2023
Resolution: Crew removed bucket with fuel and cleaned the RACOR flam bowls.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 March 2023
Resolved
Air passage through all vessels watertight doors. Vessel shall maintain watertight integrity.
Action required: 10 - Deficiency Rectified
Due 6 March 2023
Resolved 6 March 2023
Resolution: Crew tightened doors to remain watertight.