UNITED KALAVRYTA

UNITED KALAVRYTA is a 2005 tank ship. The Coast Guard has recorded 4 inspections since 2016, most recently in April 2018, along with 4 deficiencies and 2 operational controls.

Records from 2016 to 2018. Most recent: operational control imposed, 26 April 2018.

Built
2005
Last inspected
26 April 2018
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 April 2018
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9290397
810626
Flag
MARSHALL ISLANDS
Maury page id
psix-810626

Documentation record

Tonnage as PSIX records it52045 - Convention (Subpart B), Net Ton
182617 - Displacement, Ton
159156 - Dead Weight, Ton
52045 - Regulatory (Subpart C or D), Net Ton
81076 - Convention (Subpart B), Gross Ton
81076 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

26 April 2018 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6390960
26 April 2018 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6400225
8 August 2017 Ballast Water Examination · ISPS II Exam · Administrative Inspection · COC-TVE Renew · PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6227858
2 April 2016 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5843967

Deficiency record · 4

Construction/Loadline › Structures › Door
Issued 8 August 2017 Resolved
A steel door capable of being operated from each side shall be provided for access to a safe escape route from the lower part of the machinery space to the open deck. The door leading to the open deck from the funnel was unable to be opened from within the space.
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 8 August 2017
Resolution: Vessel corrected on the spot. Attached a bolt that was missing.
Communications › Visual Communication › Red Warning Signal
Issued 8 August 2017 Resolved
The tank overfill alarm required for each cargo tank of a tankship must have audible and visible alarm indications that can be seen and heard from the cargo deck area. The visual indicator for the alarm was not operational when tested.
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 8 August 2017
Resolution: Corrected on the spot by replacing bulb.
Operations/Management › Crude Oil Washing › Use of Inert Gas Systems
Issued 8 August 2017 Resolved
The IGS shall be desined, constructed and tested in accordance with the fire safety systems code and capable of delivering an oxygen content of not more than 5% by volume to the cargo tanks at any rate of flow. The crew could not demonstrate calibration of the fixed oxygen content analyser. Attending MI educated crew on the proper calibration method per the vls approved procedures manual.
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 8 August 2017
Resolution: Crew was able to properly demonstrate calibration procedures following the approved calibration procedures in the oxygen analyser manual.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 April 2016 Resolved
OWS pump no functional in presence of marine inspector. Master stated MEPC 60 OWS/OSCM wsa opertional yesterday.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 August 2017
Resolved 8 August 2017