Records from 2016 to 2025. Most recent: inspection, 22 October 2025.
Inspection history · 11
22 October 2025
Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8254204
28 January 2025
Deficiency Check · Drydock Exam · Annual Inspection · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8070625
25 January 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7854303
25 January 2023
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7626661
27 January 2022
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7381811
29 October 2020
Internal Structural Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7102278
19 September 2019
Annual Inspection · Drydock Exam · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6816237
22 January 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6612336
11 December 2017
Annual Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6319824
9 January 2017
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6065994
22 February 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5819761
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 October 2025
Resolved
A power-driven vessel of less than 12 meters in length may, in lieu of the lights prescribed in paragraph (a) of this Rule, exhibit an all-round white light and sidelights.
Vessel does not have masthead light or all-around white light.
33 CFR 83.23(d)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2025
Resolved 5 November 2025
Resolution: Vessel rep emailed a picture of an all-around white light installed above the awning.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 October 2025
Resolved
A vessel of less than 12 meters in length shall not be obliged to carry the sound signaling appliances prescribed in paragraph (a) of this Rule but if she does not, she shall be provided with some other means of making an efficient sound signal.
Vessel has no working sound signal on board.
33 CFR 83.33(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2025
Resolved 5 November 2025
Resolution: Vessel rep emailed a picture of a horn installed next to the operating station.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 October 2025
Resolved
Each vessel must be equipped with at least two operable portable battery lights.
Vessel only has one operable portable battery light.
46 CFR 183.430
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2025
Resolved 7 November 2025
Resolution: Received pictures of flashlights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 October 2025
Resolved
Each...ring life buoy must be marked with Type II retro-reflective material approved in accordance with 46 CFR 164.018.
Ring life buoy missing retro-reflective tape.
46 CFR 185.604(i)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 October 2025
Resolution: Vessel rep applied new retroreflective tape to the ring life buoy during the inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 January 2025
Resolved
A drydock examination ... During the examination all accessible parts of the vessel's underwater body and all through hull fittings, including the hull plating and planking, appendages, propellers, shafts, bearings, rudders, sea chests, sea valves, and sea strainers shall be made available for examination. MI observed port aft quarter of the deck starting to show signs of wood decay along with port fwd and starboard quarter showing visible splintering of wood fibers, allowing ingress of water into the grain of the wood. Clean and clear to good wood and conduct satisfactory repair to the Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2025
Resolved 24 February 2025
Resolution: Operator submitted photos of repairs completed, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 January 2024
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. CHILD label missing on stowage of child life jackets.
46 CFR 180.78(a)(5)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 February 2024
Resolved 2 February 2024
Resolution: Received picture of corrected deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 January 2024
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard placed so as to be easily available during an emergency. Fire buckets missing lanyard.
46 CFR 181.610
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 February 2024
Resolved 2 February 2024
Resolution: Received picture of corrected deficiency.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 26 January 2024
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Missing prove of enrollment in drug and alcohol program for employment.
46 CFR 16.230(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 February 2024
Resolved 2 February 2024
Resolution: Received picture of corrected deficiency.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 26 January 2024
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Missing alcohol swabs on board vessel.
46 CFR 4.06-15(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 February 2024
Resolved 2 February 2024
Resolution: Received picture of corrected deficiency.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 26 January 2024
Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crewmembers. The employer may establish the EAP as a part of its internal personnel services or the employer may contract with an entity that will provide EAP services to a crewmember. Missing documentation for EAP program available to the crew.
46 CFR 16.401
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 February 2024
Resolved 2 February 2024
Resolution: Received picture of corrected deficiency.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 December 2017
Resolved
Vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents. Expired medicine must be replaced.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 18 December 2017
Resolution: Replaced expired medicine.
Fire Fighting › Fire Bucket › Quantity
Issued 11 December 2017
Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets with an attached lanyard. Vessel had only one fire bucket.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 18 December 2017
Resolution: Purchased two fire buckets.
Documentation › Markings/Placards › Lifejacket Placard
Issued 11 December 2017
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places. Vessel did not have a life jacket placard.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 18 December 2017
Resolution: Purchased lifejacket placard.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 11 December 2017
Resolved
In systems where flexible hoses are permitted, double hose clamping is required where praticable. Fuel fill line was not double clamped.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 18 December 2017
Resolution: Installed double clamps on fuel fill line.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 11 December 2017
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Lettering needs to be restenciled.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 18 December 2017
Resolution: Restenciled lifejacket storage markings.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 January 2017
Resolved
Rewire aux wiring. Remove quick connections and install terminal block IAW 46 CFR 183.340 from ignition to fuse panel. 46 CFR 184.340
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 9 February 2017
Resolved 9 February 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 January 2017
Resolved
Clean up and remove unused wiring under console. 46 CFR 183.340
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 February 2017
Resolved 9 February 2017