07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 August 2025
Resolved
Equipment installed but not required.
(a) Fire extinguishing equipment installed on a vessel in excess of the requirements of §§ 181.400 and 181.500 must be designed, constructed, installed, and maintained in accordance with a recognized industry standard acceptable to the Commandant (CG-ENG-4).
(b) Use of non-approved fire detection systems may be acceptable as excess equipment provided that—
(1) Components are listed by an independent, nationally recognized testing laboratory as set forth in 29 CFR 1910.7, and are designed, installed, tested, and maintained in accordance with an appropriate industry standard and the manufacturer's specific guidance;
The following fire detection alarm sensors were not operationally tested by the NFPA 10 certified fire extinguisher servicing agency:
Forepeak Compartment, Bow Thruster Compartment, MSD Tank Compartment, Steering Compartment.
Prove proper operational test of fire detection alarm sensors to the CG Marine Inspector.
46CFR181.120
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 August 2025
Resolution: Proved proper operational test of fire detection alarm sensors: Forepeak Compartment, Bow Thruster Compartment, MSD Tank Compartment, Steering Compartment.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 4 August 2025
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: Inspection of piping, controls, and valves, and the inspection and testing of alarms and ventilation shutdowns, for each fixed gas fire extinguishing system and detection system to determine that the system is in operating condition. Inspection and testing of all smoke and fire detection systems, including sensors and alarms. During annual maintenance for the manual activated fixed fire extinguishing system for the engine compartment by an NFPA 10 certified fire extinguisher servicing agency, the audible device indicating discharge of CO2 into the space was found inoperable. Additionally, the fire detection system was unable to be tested due to insufficient expendable parts and/or equipment required to complete satisfactory testing. Make permanent repairs to the audible indicator IAW manufacture specifications, satisfactory test the fire detection system, and provide updated 3rd party servicing report documenting systems were tested and and functioning IAW manufacturer design specifications.
46CFR176.810
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2025
Resolution: The audible device indicating discharge of CO2 into engine space replaced/tested sat. Heat detector sensors for the eng space & CO2 bottle space were replaced and/or tested sat. The report documented systems were tested & functioning IAW manufacturer desi
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 29 July 2024
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel does not have posted or available emergency instructions. Post or make available emergency instructions IAW 46CFR185.512.
46CFR185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 August 2024
Resolution: Posted emergency instructions IAW 46CFR185.512 at the operating station.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 29 July 2024
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements:(1) Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. Vessel does not have a radio operator. Provide evidence of Marine Radio Operator Permit to the USCG.
47CFR80.159(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2024
Resolution: Vessel now has a radio operator. Provided evidence of Marine Radio Operator Permit to the USCG.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 29 July 2024
Resolved
A certification that the ship has passed an inspection must be entered into the ship's log by the inspecting technician. The technician conducting the inspection and providing the certification must not be the vessel's owner, operator, master, or employee or their affiliates. Additionally, the vessel owner, operator, or ship's master must certify in the station log that the inspection was satisfactory. Vessel's FCC Radiotelephony Inspection Certificate is expired. Provide valid certificate to the USCG.
47CFR80.59(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 August 2024
Resolution: Provided FCC Radiotelephony Inspection Certificate to the USCG.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 July 2024
Resolved
A vessel must carry one floating waterlight. The floating waterlight battery is expired. Replace floating waterlight battery.
46CFR180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 August 2024
Resolution: Replaced floating water light battery.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 29 July 2024
Resolved
An OCMI acceptable rescue boat is required or the vessel must be sufficiently maneuverable, arranged, and equipped to allow the crew to retrieve a helpless person from the water (approximate freeboard of less than 2 feet), with the recovery capable of being observed from the operating station. Vessel does not have a rescue boat, or approved rescue platform. IAW MPS-WI-SECSP(spi)-14, submit a rescue platform fabrication plan as an alternative to a rescue boat. Update the vessel emergency instructions to include procedures for
use of the rescue platform.
46CFR180.210
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 October 2024
Resolution: Vessel now has an approved rescue platform, IAW MPS-WI-SECSP(spi)-14. Vessel updated emergency instructions to include procedures for use of the rescue platform.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 July 2024
Resolved
A portable hand bilge pump must be:(1) Capable of pumping water, but not necessarily simultaneously, from all watertight compartments; and(2) Provided with suitable suction hose capable of reaching the bilge of each watertight compartment and discharging overboard. Portable hand bilge pump suction/discharge hose is not of sufficient length to dewater the spaces.
46CFR182.520
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 August 2024
Resolution: Portable hand bilge pump suction/discharge hose is now of sufficient length to dewater the spaces.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 July 2024
Resolved
A voltmeter and an ammeter, which can be used for measuring voltage and current of a generator that is in operation, must be provided for a generator rated at 50 volts or more. For each alternating current generator, a means for measuring frequency must also be provided. Volt & Amp meter is non-operational. Frequency meter (Hz) is not installed. Repair/replace Volt & Amp meter in kind, install Hz meter.
46CFR183.320
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2024
Resolution: Repaired Volt & Amp meters and installed Hz meter. Volt, Amp and frequency meters are now operational.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 July 2023
Resolved
Fire Hose is excessively worn and must be replaced.
Replacement fire hose must a lined commercial fire hose
that conforms to UL 19 or equivalent, 50' length, 1.5"
diameter w/ brass fittings that comply with NFPA 1963.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 August 2023
Resolution: Fire hose was replaced, installed and operation test SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 July 2023
Resolved
A spanner wrench must be provided for the fire hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2023
Resolved 10 August 2023
Resolution: A spanner wrench is provided for the fire hose.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 31 July 2023
Resolved
The fire detection sensor is non-operable in the shaft
compartment. Replace in kind.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2023
Resolved 10 August 2023
Resolution: The fire detection sensor in the shaft compartment was replaced and is now operational.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 31 July 2023
Resolved
Vessel does not have required alcohol test swabs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2023
Resolved 10 August 2023
Resolution: Vessel has the required alcohol test swabs.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 July 2023
Resolved
Side Navigation Lights are non operational. Vessel is
restricted to day time operations until corrected.
Action required: 705 - Other - as specified
Resolved 1 August 2023
Resolution: Side Navigation Lights were replaced, installed, and operational test SAT.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 31 July 2023
Resolved
Aft top deck is not marked with max passengers allowed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2023
Resolved 10 August 2023
Resolution: The aft top deck is now marked with max passengers allowed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 31 July 2023
Resolved
Engine room door must must be marked in clearly legible
letters at least 50 millimeters (2 inches) high:
“EMERGENCY EXIT, KEEP CLEAR”.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2023
Resolved 10 August 2023
Resolution: The engine room door is marked in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 July 2023
Resolved
Vessel is missing 11 Adult Life Jackets. Vessel is
restricted to a maximum of 105 pax until corrected.
Action required: 705 - Other - as specified
Resolved 10 August 2023
Resolution: The vessel added 11 Adult Life Jackets, and now has the required quantity IAW the COI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 July 2023
Resolved
The number and identification of the items stowed
inside, and their sizes, must be marked in clearly
legible letters and numbers on each container for life
jackets. Incorrect quantity is marked on containers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2023
Resolved 10 August 2023
Resolution: The number and identification of the items stowed inside, and their sizes, are now marked in clearly legible letters and numbers on each container for life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 July 2023
Resolved
Ring Life Buoy Lettering is faded and must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2023
Resolved 10 August 2023
Resolution: The Ring Life Buoy Lettering was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 July 2023
Resolved
Ring Life Buoy Floating Waterlight landyard must be 3-6'
in length, securing the waterlight around the body of
the ring life buoy with a corrosion resistant clip.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2023
Resolved 10 August 2023
Resolution: The Ring Life Buoy Floating Water light lanyard is now 3-6' in length, securing the water light around the body of the ring life buoy with a corrosion resistant clip.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 July 2023
Resolved
Exposed wiring was identified in the engine room, on the
port side bulkhead of the ladder vestibule.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2023
Resolved 12 September 2023
Resolution: Exposed wiring was eliminated in the engine room, on the port side bulkhead of the ladder vestibule.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 31 July 2023
Resolved
An exposed watertight bulkhead penetration was
identified in the shaft compartment and steering space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2023
Resolved 10 August 2023
Resolution: An exposed watertight bulkhead penetration was corrected in the shaft compartment and steering space.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 31 July 2023
Resolved
Propulsion engine shaft guards are not secured in place.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2023
Resolved 10 August 2023
Resolution: Propulsion engine shaft guards are now secured in place.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 31 July 2023
Resolved
The port engine exhaust pipe insulation is worn,
exposing hot piping and must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2023
Resolved 16 September 2023
Resolution: The port engine exhaust pipe insulation was replaced.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 31 July 2023
Resolved
MSD overboard discharge valve is not properly secured.
Secure valve to prevent accidental discharge of sewage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2023
Resolved 10 August 2023
Resolution: MSD overboard discharge piping was not needed and removed.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 31 July 2023
Resolved
MSD operation instructions are not posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2023
Resolved 16 September 2023
Resolution: MSD operation instructions are now posted.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 31 July 2023
Resolved
Starboard fuel vent screen is ripped.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2023
Resolved 10 August 2023
Resolution: Starboard fuel vent screen was replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 October 2022
Resolved
Vessel was identified as having potential damage from Hurricane IAN. Prior to conducting repairs, contact the local USCG Marine Inspections office and submit a repair proposal for approval. Vessel is not permitted to return to commercial service until cleared by a USCG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 December 2022
Resolution: Repairs were made to the starboard forward top deck.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 July 2021
Resolved
Bottom generator suffered a casualty after a loss of coolant. Engine room filled with smoke - no other damage noted. Top generator is fully functional. Prove proper operation of bottom generator on load to the satisfaction of a Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2021
Resolved 15 July 2021
Resolution: Witnessed satisfactory operation of bottom generator on load.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 May 2021
Resolved
Chart, Light List and Coastal Pilot needs to be updated
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2021
Resolved 14 May 2021
Resolution: Received photos of new publications onboard.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 10 May 2021
Resolved
Display emergency broadcast placard IWO VHF radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2021
Resolved 14 May 2021
Resolution: Received photo of new placard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 May 2021
Resolved
Electrical matting was not present in front of 110 volt AC switchboard. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 10 May 2021
Resolved 10 May 2021
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2021
Resolved
Divide child and adult lifejackets under the bar and properly mark stowage location.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2021
Resolved 14 May 2021
Resolution: Received photos of separated life jackets and new marking.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 3 June 2019
Resolved
FCC Station License and FCC safety, cert, and bridge to bridge are expired, stay 1000' from shore on portected waters only. (47CFR30.15 and 47CFR155.303).
Action required: 705 - Other - as specified
Resolved 4 June 2019
Resolution: Received new certificates.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 June 2019
Resolved
Replace all expired items in first aid kit (46CFR184.710)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2019
Resolved 4 June 2019
Resolution: Went through kit and replaced all expired items.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 June 2019
Resolved
Provide proof of drug testing enrollment. (46CFR16.230)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2019
Resolved 4 June 2019
Resolution: Printed valid enrollment form.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 June 2019
Resolved
Provide proper nautical chart with current notice to mariners (46CFR184.420)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2019
Resolved 4 June 2019
Resolution: Purchased new chart.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 3 June 2019
Resolved
Provide current tide tables (46CFR184.420)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2019
Resolved 4 June 2019
Resolution: Purchased current tide tables.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 June 2019
Resolved
Provide new bulb in stern light. (33CFR83.21)
Action required: 705 - Other - as specified
Resolved 4 June 2019
Resolution: New bulb installed.
Engineering › Fuel Oil Service System › Piping
Issued 14 May 2018
Resolved
Replace fule return line on lower generator due to wastage. (46CFR176.800)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2018
Resolved 30 May 2018
Resolution: Replaced fuel line
Navigation › Piloting/Steering › Marine Charts
Issued 14 May 2018
Resolved
Purchase updated chart with local notice to mariners. (46CFR184.420)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2018
Resolved 30 May 2018
Resolution: Purchased approved chart.
Lifesaving › Lifebuoys › Serviceable
Issued 14 May 2018
Resolved
Replace faded retro tape on life ring. (46CFR180.70)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2018
Resolved 30 May 2018
Resolution: Replaced retro tape.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 14 May 2018
Resolved
Purchase oil pollution placard. (33CFR155.150)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2018
Resolved 30 May 2018
Resolution: Purchsaed and placed placard.
Engineering › Steering Gear System › Rudder
Issued 18 September 2017
Resolved
Repack starboard rudder. (46FR176.600)
Action required: 705 - Other - as specified
Resolved 27 September 2017
Resolution: Repacked starboard rudder, all sat.
Fire Fighting › Fire Main › Condition
Issued 23 May 2017
Resolved
Fire main has pin hole leak above main deck due to rust/waste. Do not carry more than 49 passengers until fixed. Require 3 2.5 gallon fire buckets on board until fixed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2017
Resolution: fire main pin hole repaired.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 23 May 2017
Resolved
Schematic diagram for CO2 system needed with alternate release instructions. 46 CFR 185.617
Action required: 705 - Other - as specified
Due 6 June 2017
Resolved 5 June 2017
Resolution: posted schematic.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 23 May 2017
Resolved
Door to engine room needs to be marked properly for space protected by CO2. 46 CFR 185.612(g)(2)
Action required: 705 - Other - as specified
Due 6 June 2017
Resolved 5 June 2017
Resolution: Posted proper warning sign.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 23 May 2017
Resolved
Hatch to CO2 storage needs to be marked for storing CO2. 46 CFR 185.612(g)(1)
Action required: 705 - Other - as specified
Due 6 June 2017
Resolved 5 June 2017
Resolution: Posted proper sign for storing CO2 in a space.