MAURY USCG vessel records Sign in
← All vessels

CYRUS E. KING

CYRUS E. KING is a 1962 passenger vessel (inspected). The Coast Guard has recorded 39 inspections since 1990, most recently in March 2007, along with 69 deficiencies — 5 with no resolution recorded —.

Records from 1990 to 2007. Most recent: inspection, 12 March 2007.

Built
1962
Last inspected
12 March 2007
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAX3092
Flag
UNITED STATES
—
Maury page id
psix-81168

Inspections, by type

…with no type recorded1
…past their stated due date5
Years with a record 18 calendar years (1990–2007)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)47.3 ft × 14.5 ft × 5.6 ft
Registered tonnagegross 22 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTOCHE BOAT BUILDERS & REP · OCEAN SPRINGS, MS, UNITED STATES · built 1962
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Regulatory (Subpart C or D), Net Ton
22 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WAX3092MMSI not assigned · expired · voluntarily equipped · granted 1 July 1996, cancelled 23 September 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 39

12 March 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2884961
24 July 2006 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2723014
14 June 2006 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2679475
20 January 2006 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2570058
10 November 2005 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2536066
14 June 2005 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2377402
22 February 2005 Hull Examination · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2296684
29 November 2004 Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2249954
5 March 2004 Annual Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2018776
21 August 2003 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1882038
8 July 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1831970
3 December 2002 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1707375
24 April 2002 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1609090
14 March 2002 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1484941
30 April 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1063270
10 April 2000 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 816827
15 March 1999 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446737
17 November 1998 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1411765
20 March 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446656
18 April 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1100279
14 March 1997 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1402408
3 January 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1093609
8 November 1996 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1392570
22 August 1996 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1259753
31 July 1996 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1091042
15 March 1996 Deficiency Check · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1404106
3 March 1995 Hull Examination · Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1419385
17 March 1994 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1165607
8 September 1993 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1142915
25 March 1993 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 841976
24 February 1993 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1150579
3 April 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 946574
19 March 1992 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 947178
18 September 1991 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1243934
16 April 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 912411
16 April 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1239861
21 March 1991 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1216577
20 March 1991 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 926852
1 March 1990 Hull Examination · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1222019

Deficiency record · 69

Construction/Loadline › Penetrations › Valve Flange
Issued 12 March 2007 No resolution recorded
Provide and install a plug/cap in the second most forward through hull fitting/valve port side in accordance with 46 CFR 182 to the satisfaction of the attending marine inspector.
Due 12 April 2007 — due date passed with no resolution recorded
Construction/Loadline › Penetrations › Valve Flange
Issued 12 March 2007 No resolution recorded
Provide and install valve handles to both cock pit drain through hull fittings/valves in accordance with 46 CFR 182 to the satisfaction of the attending marine inspector.
Due 12 April 2007 — due date passed with no resolution recorded
Engineering › Steering Gear System › Linkage
Issued 12 March 2007 No resolution recorded
Replace all shives in the steering system in accordance with 46 CFR 182.600 and prove operation of steering system to the satisfaction of the attending marine inspector.
Due 12 April 2007 — due date passed with no resolution recorded
Deck/Cargo › Mooring/Anchoring › End Link (anchor chain)
Issued 12 March 2007 No resolution recorded
Replace the deteriorated shackles on the aft shroud on the port side in accordance with 46 CFR 176.800to the satisfaction of the attending marine inspector.
Due 12 April 2007 — due date passed with no resolution recorded
Construction/Loadline › Hull › Hull Plating
Issued 12 March 2007 No resolution recorded
Remove and replace the deteriorated hull planking on the stern below the water line as marked port side. Remove all excessive putty in other areas and make butts seams ready for inspection in accordance with NVIC 7-95 prior to granting credit for hull examination.
Due 12 April 2007 — due date passed with no resolution recorded
Documentation › Logs/Records › Logbook (official)
Issued 19 June 2006 Resolved
Provide current training logbook, bridge logbook, and lifesaving equipment maintenance log as required by 46 cfr 185.420 and185.702
Action required: 705 - Other - as specified
Due 19 July 2006
Resolved 24 July 2006
Resolution: The required logs and records were onboard.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 19 June 2006 Resolved
Properly mark areas on the bow and stern to convey the restricted areas for passengers in accordance with 46 CFR 185.602
Action required: 705 - Other - as specified
Due 19 July 2006
Resolved 24 July 2006
Resolution: The areas were marked with signs for crew only.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 19 June 2006 Resolved
Properly stencil and provide retro reflective tape on lifejackets where needed in accordance with 46 CFR 185.604
Action required: 705 - Other - as specified
Due 19 July 2006
Resolved 24 July 2006
Resolution: The lifejackets had new retro reflective tape on them and they were properly stenciled.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 19 June 2006 Resolved
Properly mount B-1 Fire extinguisher at the operating station in accordance with 46 CFR 181.520
Action required: 705 - Other - as specified
Due 19 July 2006
Resolved 24 July 2006
Resolution: The extinguisher was mounted in a proper mounting bracket.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 19 June 2006 Resolved
Double nut the shaft packing in the engine room in accordance with 46 CFR 176.800
Action required: 705 - Other - as specified
Due 19 July 2006
Resolved 24 July 2006
Resolution: The packing gland was properly double nutted.
Engineering › Fuel Oil Service System › Piping
Issued 19 June 2006 Resolved
Provide cap on the piping for the port fuel tank
Action required: 705 - Other - as specified
Due 19 July 2006
Resolved 24 July 2006
Resolution: A pipe cap was installed on the drain from the fuel tank.
Engineering › Bilge Water Management System › Interface Detector
Issued 19 June 2006 Resolved
Provide proper operation of the bidge high level alarms in accordance with 46 CFR 182.530
Action required: 705 - Other - as specified
Due 19 July 2006
Resolved 24 July 2006
Resolution: The bilge high level alarm was tested with satisfactory results.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 June 2006 Resolved
Properly stencil lifering and replace the grablines in accordance with 46 CFR 180.78
Action required: 705 - Other - as specified
Due 19 July 2006
Resolved 24 July 2006
Resolution: The grab line on the life ring was replaced and the ring was properly stenciled.
Construction/Loadline › Structures › Superstructure
Issued 19 June 2006 Resolved
Properly repair or replace cracked blocks where needed
Action required: 705 - Other - as specified
Due 19 July 2006
Resolved 24 July 2006
Resolution: Repairs were made to the blocks.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 14 June 2005 Resolved
Renew or repair oil pressure gauge at main engine as per 46 CFR 182.20-5
Action required: 705 - Other - as specified
Due 14 July 2005
Resolved 10 November 2005
Resolution: Gauge operational
Communications › Alarms/Indicators › Fire Alarm
Issued 14 June 2005 Resolved
Renew or repair smoke detector in accommodation space as per 46 CFR 181.450
Action required: 705 - Other - as specified
Due 14 July 2005
Resolved 10 November 2005
Resolution: New smoke detector installed and operable
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 14 June 2005 Resolved
Provide FCC Marine Radio Operators permit 46 CFR 184.502
Action required: 705 - Other - as specified
Due 14 July 2005
Resolved 10 November 2005
Resolution: Vessel will not operate more than 1000 feet from shore, operator permit not required.
Communications › Audible Communications › Bell
Issued 14 June 2005 Resolved
Provide proper navigation bell as per 33 CFR part 86
Action required: 705 - Other - as specified
Due 14 July 2005
Resolved 10 November 2005
Resolution: Proper bell mounted
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 14 June 2005 Resolved
Provide updated navigation publications as required by 46 CFR 184.420
Action required: 705 - Other - as specified
Due 14 July 2005
Resolved 10 November 2005
Resolution: all publications updated
Construction/Loadline › Structures › Door
Issued 14 June 2005 Resolved
Provide cative chain or line to forward emergency escape hatch as required by 46 CFR 171.124(b)
Action required: 705 - Other - as specified
Due 14 July 2005
Resolved 10 November 2005
Resolution: Tether connected
Construction/Loadline › Structures › Superstructure
Issued 14 June 2005 Resolved
Repair blocks in rigging as per 46 CFR 177.330
Action required: 705 - Other - as specified
Due 14 July 2005
Resolved 10 November 2005
Resolution: All worn blocks, replaced
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 June 2005 Resolved
Label fuel shutoff valves in accorance with 46 CFR 185.30-20
Action required: 705 - Other - as specified
Due 14 July 2005
Resolved 10 November 2005
Resolution: Fuel shutoffs labeled
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 14 June 2005 Resolved
Repair leaking shaft packing and prove tightness as per 46 CFR 176.802(c)
Action required: 705 - Other - as specified
Due 14 July 2005
Resolved 10 November 2005
Resolution: New packing installed
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 June 2005 Resolved
Make electrical connections for electrical bilge pump in watertight electrical box as per 46 CFR 183.340(g)
Action required: 705 - Other - as specified
Due 14 July 2005
Resolved 10 November 2005
Resolution: Connections satisfactory
Engineering › Bilge Water Management System › Strainer
Issued 14 June 2005 Resolved
Clean trash from bilge IAW 46 CFR 176.830
Action required: 705 - Other - as specified
Due 14 July 2005
Resolved 10 November 2005
Resolution: bilges cleaned
Construction/Loadline › Structures › Superstructure
Issued 14 June 2005 Resolved
Renew topping lift on forward mast rigging as per 46 CFR 177.330
Action required: 705 - Other - as specified
Due 14 July 2005
Resolved 10 November 2005
Resolution: Topping lift renewed
Fire Fighting › Fire Bucket › Quantity
Issued 25 May 2004 Resolved
Provide missing fire bucket for the required total of three IAW 46 CFR 181.610.
Action required: 705 - Other - as specified
Due 25 June 2004
Resolved 25 May 2004
Resolution: Immediately supplied a proper firebucket.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 May 2004 Resolved
Repair/replace loose hand rail stanchions IAW 46 CFR 177.900(b).
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 June 2004
Resolved 22 February 2005
Resolution: Hand rail was secured IAW 46 CFR 177.900
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 May 2004 Resolved
Provide missing navigation publication CG Light List IAW 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 25 June 2004
Resolved 22 February 2005
Resolution: CG Light list was provided.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 25 May 2004 Resolved
Repair/close/seal small space in bulkhead between engine compartment and accommodation space to make engine room gas tight IAW 46 CFR 177.405(c).
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 June 2004
Resolved 25 May 2004
Resolution: Immediately adjusted wooden panel and caulked the remaining crack.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 25 May 2004 Resolved
Provide missing navigation publications of Tide/Current Tables IAW 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 25 June 2004
Resolved 22 February 2005
Resolution: Tide/Current Tables were provided.
Navigation › Piloting/Steering › US Coast Pilot
Issued 25 May 2004 Resolved
Provide missing navigation publication US Coast Pilot IAW 46 CFR 184.420.
Due 25 June 2004
Resolved 22 February 2005
Resolution: Coast Pilot was provided.
Stability › Weathertight Integrity
Issued 8 July 2003 Resolved
Replace wing nut on port lights in main cabin as required by 46 CFR 177.80(c).
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 21 August 2003
Resolution: All wing nuts replaced.
Stability › Weathertight Integrity
Issued 8 July 2003 Resolved
Replace cracked window at galley sink as required by 46 CFR 177.800(c).
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 21 August 2003
Resolution: All windows replaced with new plexiglass windows.
Stability › Weathertight Integrity
Issued 8 July 2003 Resolved
Provide weathertight cover for ventilation opening on the aft part of the cabin.
Due 8 August 2003
Resolved 21 August 2003
Resolution: Owner installed new ventilation covers for the aft part of the cabin.
Accommodation/Occupational Safety › Occupational Safety
Issued 8 July 2003 Resolved
Replace frayed lifelines on th the starboard aft side IAW 46 CFR 177.900(f). LEGACY COMPONENT DESC: Lifeline
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 21 August 2003
Resolution: Life lines replaced and found satisfactory.
Engineering › Sea-water System (primary cooling)
Issued 8 July 2003 Resolved
Replace hose at main diesel water cooling pump with approved hose IAW 46 CFR 182.720(e). LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 21 August 2003
Resolution: Hose replaced with approved hose. Installation found satisfactory.
Documentation › Markings/Placards
Issued 8 July 2003 Resolved
Provide lifejacket donning placard IAW 46 CFR 185.516.
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 21 August 2003
Resolution: Owner posted new lifejacket donning placards.
Lifesaving › Lifebuoys
Issued 8 July 2003 Resolved
Renew and/or replace ring bouy with proper lifeline IAW 46 CFR 180.70(c).
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 21 August 2003
Resolution: Ring bouy replaced with new lifeline.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 8 July 2003 Resolved
Mount portable fire extinguisher in the cockpit well IAW 4 CFR 181.500.
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 21 August 2003
Resolution: Portable fire extinguisher in the cockpit well properly mounted.
Documentation › Markings/Placards
Issued 8 July 2003 Resolved
Mark fuel shut off valves IAW 46 CFR 185.30-20(1995).
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 21 August 2003
Resolution: Fuel shutoff valves in the cabin properly labeled.
Engineering › Bilge Water Management System
Issued 8 July 2003 Resolved
Repair bilge switch in engine room IAW 46 CFR 182.570 (e).
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 21 August 2003
Resolution: Bilge switch replaced. Operational test satisfactory.
Navigation › Piloting/Steering
Issued 14 March 2002 Resolved
Provide on board the vessel updated Tide and Current tables as required by 46CFR184.420. The required publications shall be provided no later than 24APR02 to the satisfaction of the attending inspector. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Due 24 April 2002
Resolved 24 April 2002
Resolution: NONE
Accommodation/Occupational Safety
Issued 30 April 2001 Resolved
PROVIDE DECK RAILS AS REQUIRED BY 46 CFR 177.900
Condition: Unknown
Due 1 June 2001
Resolved 14 March 2002
Resolution: Inspected rails during COI. Courses were added.
Lifesaving
Issued 14 March 1997 Resolved
PROVIDE AND POST A LIFEJACKET DONNING PLACARD IN ACCORDANCE WITH 46 CFR 185.516.
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Navigation
Issued 14 March 1997 Resolved
PROVIDE UP TO DATE CHARTS AND PUBLICATIONS OF THE VESSEL'S OPERATING AREA IAW 46 CFR 184.420.
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Fire Fighting
Issued 14 March 1997 Resolved
RENEW BROKEN PORTABLE FIRE EXTINGUISHER BRACKET IN THE MAIN CABIN IAW 46 CFR 181.520.
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Documentation
Issued 14 March 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Accommodation/Occupational Safety
Issued 14 March 1997 Resolved
PROPERLY MARK THE INTERIOR/EXTERIOR OF THE FORWARD ESCAPE HATCH IAW 46 CFR 185.606.
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Documentation
Issued 14 March 1997 Resolved
PROVIDE AN UP TO DATE TRAINING LOG IAW 46 CFR 185.420.
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Engineering
Issued 8 November 1996 Resolved
PROVIDE A FUEL SHUTOFF VALVE AT THE MAIN ENGINE IAW 46 CFR 182.455(B)(4)
Condition: Unknown
Due 8 November 1996
Resolved 8 November 1996
Construction/Loadline
Issued 8 November 1996 Resolved
RENEW THE STARBOARD AFT PORT LIGHT GLASS, LOCATED IN THE MAIN CABIN IAW 46 CFR 177.1010.
Condition: Unknown
Due 8 November 1996
Resolved 8 November 1996
Navigation
Issued 8 November 1996 Resolved
RENEW/REPAIR THE WORN BOTTOM RUDDER PIVOT PIN IAW 46 CFR 182.30-1
Condition: Unknown
Due 8 November 1996
Resolved 8 November 1996
Construction/Loadline
Issued 8 November 1996 Resolved
PROPERLY BOND ALL THRU-HULL FITTINGS TO GROUND THROUGHOUT THE VESSEL IAW COAST GUARD NVIC 7-95.
Condition: Unknown
Due 8 November 1996
Resolved 8 November 1996
Lifesaving
Issued 8 November 1996 Resolved
PROVIDE RETRO-REFLECTIVE MATERIAL TO THE VESSEL'S RING BUOYS IAW 46 CFR 185.604(I).
Condition: Unknown
Due 8 November 1996
Resolved 8 November 1996
Construction/Loadline
Issued 15 March 1996 Resolved
CONDUCT A UNDERWAY SEA TRIAL FOR WOODEN VESSELS OVER 15 YEARS OLD TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. VSL RESTRICTED FROM CARRING PASSENGERS UNTIL COMPLETED.
Condition: Unknown
Due 15 March 1996
Resolved 21 March 1996
Electrical
Issued 15 March 1996 Resolved
PROVIDE TWO PORTABLE EMERGENCY LIGHTS, PROPERLY MARKED AND PRE-LOCATED IAW 46 CFR 183.430.
Condition: Unknown
Due 15 March 1996
Resolved 21 March 1996
Engineering
Issued 15 March 1996 Resolved
PROVE PROPER OPERATION OF MAIN ENGINES AND CONTROLS, TO BE COMPLETED TO THESATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 15 March 1996
Resolved 21 March 1996
Engineering
Issued 3 March 1995 Resolved
REPAIR FUEL LEAK AROUND FUEL FILTER ON ENGINE.
Condition: Unknown
Due 6 April 1995
Resolved 7 April 1995
Engineering
Issued 3 March 1995 Resolved
INSTALL MACHINERY GUARDS AROUND PULLEYS ON ENGINE.
Condition: Unknown
Due 6 April 1995
Resolved 7 April 1995
Construction/Loadline
Issued 3 March 1995 Resolved
SEE MARINE INSPECTION NARATIVE SUPPLEMENT FOR CASE #MI95010009 FOR SPECIFICDETAILS.
Condition: Unknown
Due 3 March 1995
Resolved 22 March 1995
Electrical
Issued 19 March 1992 Resolved
INSTALL PROPER FRESHWATER PUMP FUSE.
Condition: Unknown
Due 1 April 1992
Resolved 8 April 1992
Construction/Loadline
Issued 19 March 1992 Resolved
REPLACE BILGE VENT HOSE WITH PROPER MATERIAL.
Condition: Unknown
Due 1 April 1992
Resolved 8 April 1992
Accommodation/Occupational Safety
Issued 19 March 1992 Resolved
INSTALL NEW INTAKE HOSE FOR HEAD STARBOARD SIDE.
Condition: Unknown
Due 1 April 1992
Resolved 8 April 1992
Electrical
Issued 19 March 1992 Resolved
INSTALL PROPER WIRE SUPPORTS WITHIN ENGINE ROOM AND LIVING SPACES.
Condition: Unknown
Due 1 April 1992
Resolved 8 April 1992
Unknown
Issued 21 March 1991 Resolved
INSTALL FIXED BILGE SYSTEM FWD AND AFT WITH HARD PIPING
Condition: Unknown
Due 21 March 1991
Resolved 21 March 1991
Unknown
Issued 21 March 1991 Resolved
INSTALL DUCTING TO ENGINE ROOM VENTILATION_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 March 1991
Resolved 21 March 1991
Unknown
Issued 21 March 1991 Resolved
INSTALL EMERGENCY FUEL SHUTOFFS OPERABLE FROM MAIN DECK.
Condition: Unknown
Due 21 March 1991
Resolved 21 March 1991
Electrical
Issued 21 March 1991 Resolved
INSTALL PROPER ELECTRICAL DISTRIBUTION PANEL
Condition: Unknown
Due 21 March 1991
Resolved 21 March 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.