Records from 1995 to 2020. Most recent: inspection, 3 February 2020.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 16
3 February 2020
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6901616
29 June 2015
Administration · Industry Initiated Exam · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5170086
19 October 2012
Industry Initiated Exam · Administration · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4470589
14 March 2011
Administration
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3963446
13 November 2009
DAPI Audit
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3632946
16 October 2007
Deficiency Check · Administrative Inspection · Uninspected Other
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3080991
30 June 2005
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2410460
16 August 2004
Annual Inspection
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 2167651
21 November 2003
Annual Inspection
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1952115
11 December 1998
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 423858
3 November 1997
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 409629
29 September 1997
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 408698
14 November 1995
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 655632
29 August 1995
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 56739
29 August 1995
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 195181
29 August 1995
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 382538
Electrical › Electric Generation Source (service) › Generator
Issued 16 October 2007
Resolved
Determine source of generator oil leak and properly repair.
Condition: Improper/Lack of Maintenance
Due 1 March 2008
Resolved 17 April 2008
Electrical › Electric Generation Source (service) › Generator
Issued 16 October 2007
Resolved
Properly install the new generator flexible fuel line.
Condition: Improper/Lack of Maintenance
Due 31 March 2008
Resolved 22 April 2008
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 16 October 2007
Resolved
Properly insulate the MDE's and generator dry exhaust piping.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2008
Resolved 17 April 2008
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 16 October 2007
Resolved
Re-install the missing hand rail on the engineroom stairs.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2008
Resolved 17 April 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 16 October 2007
Resolved
Install a clear shied on the galley, overhead, florescent lights.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2008
Resolved 17 April 2008
Fire Fighting › Fixed Fire Detection System › Approval
Issued 16 October 2007
Resolved
Once installed, ensure the heat detection system is approved by a PE and a approval letter is issued.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2008
Resolved 22 April 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 16 October 2007
Resolved
Install an approved B-V semi-portable fire extinguisher.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2008
Resolved 17 April 2008
Fire Fighting › Remote Fuel Shutoff › General
Issued 16 October 2007
Resolved
Ensure the fuel shut off valves, reach rods, where they penetrate the main deck, are watertight and operate properly. Properly label both fuel shut-off valves.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2008
Resolved 22 April 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 October 2007
Resolved
Install a generator starter button.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2008
Resolved 22 April 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 October 2007
Resolved
Replace all broken window glass with plex-glass or tempered glass.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2008
Resolved 17 April 2008
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 16 October 2007
Resolved
Remove all wood and flammables from the vessel bilge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2008
Resolved 22 April 2008
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 16 October 2007
Resolved
Ensure the company's drug and alcohol program is in compliance with 46CFR16.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2008
Resolved 17 April 2008
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 16 October 2007
Resolved
Ensure the portable fire pump has 50 foot of lined commercial fire hose installed.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 22 April 2008
Resolved 22 April 2008
Lifesaving › Emergency Outfit › Protective Clothing
Issued 11 December 1998
Resolved
PERFORM GENERAL HOUSEKEEPING IN ENGINEROOM.
Condition: Unknown
Due 11 January 1999
Resolved 28 November 2007
Lifesaving › Emergency Outfit › Protective Clothing
Issued 11 December 1998
Resolved
STBD MAIN ENGINE MISSING A MACHINERY GUARD.
Condition: Unknown
Due 11 January 1999
Resolved 28 November 2007
Lifesaving › Buoyant Apparatus › Approval
Issued 11 December 1998
Resolved
GLOBES/GUARDS MISSING FROM ENGINEROOM LIGHTS.
Condition: Unknown
Due 11 January 1999
Resolved 28 November 2007
Lifesaving › Buoyant Apparatus › Approval
Issued 11 December 1998
Resolved
MISC WIRING NEED REPAIR IN ENGINEROOM AND REMOVE ALL INOPERABLE EQUIPMENT IN ENGINEROOM.
Condition: Unknown
Due 11 January 1999
Resolved 28 November 2007
Engineering › Bilge Water Management System › Piping
Issued 11 December 1998
Resolved
FLAME SCREENS MISSING FROM 3 FUEL TANK VENTS.
Condition: Unknown
Due 11 January 1999
Resolved 28 November 2007
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 11 December 1998
Resolved
ORIGINAL CERTIFICATE OF DOCUMENTATION NOT ONBOARD.
Condition: Unknown
Due 28 November 2007
Resolved 28 November 2007
Documentation › Certificates/Documents › Stability Letter
Issued 29 September 1997
Resolved
MAGNETIC COMPASS NOT ON BOARD.
Condition: Unknown
Due 29 October 1997
Resolved 28 November 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 September 1997
Resolved
WHITE STERN LIGHT MISSING
Condition: Unknown
Due 29 October 1997
Resolved 25 August 2004
Resolution: Lights installed by vessels crew.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 29 September 1997
Resolved
C.G. LIGHT LIST NOT ON BOARD.
Condition: Unknown
Due 29 October 1997
Resolved 28 November 2007
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 29 September 1997
Resolved
LOCAL NOTICE TO MARINERS NOT ON BOARD.
Condition: Unknown
Due 29 October 1997
Resolved 28 November 2007
Navigation
Issued 29 September 1997
Resolved
AMBER GLOBES MISSING FROM TOWING LIGHTS
Condition: Unknown
Due 29 September 1997
Resolved 7 October 1997
Lifesaving
Issued 29 August 1995
Resolved
RING BUOY NOT IN SERVICABLE CONDITION.
Condition: Unknown
Due 13 September 1995
Resolved 13 September 1995
Fire Fighting
Issued 29 August 1995
Resolved
REQUIRED FIRE EXTINGUISHERS MISSING.
Condition: Unknown
Due 13 September 1995
Resolved 13 September 1995