MR JIM is a 2006 passenger vessel (inspected). The Coast Guard has recorded 8 inspections since 2016, most recently in November 2020, along with 9 deficiencies.

Records from 2016 to 2020. Most recent: inspection, 6 November 2020.

Built
2006
Last inspected
6 November 2020
Documentation
Case Pending · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDD2211
812331
Flag
UNITED STATES
Maury page id
psix-812331

Inspections, by type

Years with a record 5 calendar years (2016–2020)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)46.5 ft × 15.0 ft × 6.5 ft
Registered tonnagegross 30 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEVILLE BOAT WORKS INC · NEW IBERIA, LA, UNITED STATES · built 2006
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 7 April 2006
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Simplified, Net Ton
30 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 8

6 November 2020 Administrative Inspection
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7090881
29 May 2020 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6963657
25 June 2019 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6726160
9 April 2018 Drydock Exam · Internal Structural Exam · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6389030
19 April 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6132200
9 February 2017 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6097278
19 May 2016 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5881210
12 April 2016 Internal Structural Exam · COI Inspection · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5852625

Deficiency record · 9

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 25 June 2019 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Both life floats located on the port and starboard cabin overhead were observed to have excessive deterioration of the external protective covering. Vessel shall replace/repair prior to departing. 46 CFR 180.175
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2019
Resolution: Vessel owner replaced both lifefloats with newly purchased lifefloats.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 June 2019 Resolved
Each EPIRB must be tested monthly using the integrated test circuit and output indicator, to determine that it's operative; the EPIRB test shall be logged or otherwise documented. Vessel logs did not indicate a monthly testing of the EPIRB. Ensure monthly tests are being documented in the vessel log. 46 CFR 185.728(c)
Action required: 10 - Deficiency Rectified
Resolved 25 June 2019
Resolution: Vessel master and port captain informed to ensure monthly compliance is adhered to.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 25 June 2019 Resolved
The owner or master shall instruct each crew member at least once every three months as to the duties the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard. Crew training shall be logged or otherwise documented. The training entry shall include the date of the training and the general description of the training topics. Vessel records only indicated that drills were being performed but did not indicate any training, including training for rough weather at sea or flooding, as outlined on the vessels emergency instruction.46 CFR 185.420(a) & (c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 9 July 2019
Resolution: Master of vsl conducting proper training and provided evidence of log entry. (Vessel manning is one master).
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 June 2018 Resolved
Navigation lights were not in working order, which need to be corrected within two weeks, or prior to operating at night or during low visibility.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2018
Resolved 14 July 2018
Resolution: Corrected.
Engineering › Sea-water System (primary cooling) › Piping
Issued 25 June 2018 Resolved
Seawater cooling system non-metallic piping on the Port MDE has a loose clamp, which needs to be tightened or replaced. Three bolts are also missing from the support brackets for the cooling system piping, which need to be installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 14 July 2018
Resolution: Corrected.
Communications › Radio Communications › VHF Radiotelephone
Issued 9 April 2018 Resolved
VHF DSC is not operational, which needs to be corrected within two weeks.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2018
Resolved 14 July 2018
Resolution: Corrected.
Lifesaving › Lifefloat › Retroreflective Material
Issued 14 April 2016 Resolved
Retroreflective material is worn out and must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 14 April 2016
Resolution: Corrected on the spot.
Communications › Radio Communications › VHF Radiotelephone
Issued 14 April 2016 Resolved
VHF radios' (DSC) is not operational as required.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 19 May 2016
Resolution: DSC installed correctly; was tested in the presence of the attending marine inspector; operated satisfactorily.
Communications › Radio Communications › EPIRB
Issued 12 April 2016 Resolved
EPIRB was not marked with the battery expiration date.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 19 May 2016
Resolution: EPIRB was serviced and battery expiration date was updated/placed on the EPIRB by servicing facility as required. Verified by attending marine inspector.