Records from 2016 to 2020. Most recent: inspection, 9 November 2020.
Documentation record
Registered dimensions (L × B × D)46.5 ft × 15.0 ft × 6.5 ft
Registered tonnagegross 30 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEUVILLE BOAT WORKS INC · NEW IBERIA, LA, UNITED STATES · built 2006
Hull materialAluminum
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 7 April 2006
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Simplified, Net Ton
30 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 8
9 November 2020
Administrative Inspection
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7092488
29 May 2020
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6963581
15 August 2019
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6785559
29 May 2018
Hull Examination · Internal Structural Exam · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6428273
19 July 2017
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6214056
12 December 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6065616
1 December 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6097317
7 June 2016
Hull Examination · Deficiency Check · Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5952718
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 August 2019
Resolved
Vessels under 20 meters shall provide a sound signal device that is audible for .5 NM. Vessel's electric horns located on the mast were not producing a strong sound signal. Vessel will be replacing both horns and will test. 33 CFR Table 86.01(c).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2019
Resolution: Sound producing horn was replaced.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 15 August 2019
Resolved
Ventilation supply ducts must have a provision for closing all ducts for a space protected by a fixed gas system. The port forward and port aft ventiliation closures were unbale to be removed from their support brackets to be installed. Crew to clean paint build up and fit test. 46 CFR 182.465(h)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2019
Resolution: Fire ventilation closures were cleaned and tested for ease of installation.
Communications › Radio Communications › EPIRB
Issued 31 May 2018
Resolved
EPIRB missing battery expiration date; to be corrected prior to operating beyond 3NM offshore.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 June 2018
Resolved 25 June 2018
Resolution: EPIRB battery was replaced by a servicing facility.
Lifesaving › Lifefloat › Paddle
Issued 31 May 2018
Resolved
Port side lifefloat paddles are wasted and brittle, which need to be replaced prior to operating.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2018
Resolved 25 June 2018
Resolution: Paddles were replaced with new ones.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 31 May 2018
Resolved
Machinery space ventilation fire dampers need to be unsiezed from their stowage location prior to operating.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2018
Resolved 25 June 2018
Resolution: Dampers were unsiezed.
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 29 May 2018
Resolved
Port Main Diesel propulsion engine overheated while underway to conduct MOB drill; jacketwater pump needs to be repaired prior to operating.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2018
Resolved 25 June 2018
Resolution: Pump replaced.
Engineering › Steering Gear System › Pump
Issued 26 July 2016
Resolved
Orbital Steering pump under P/H console was leaking hydraulic fluid. Capt to tighten fittings, operate, and check for leaks to include cleaning oily water in bilge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2016
Resolution: Repaired and tested sat.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 26 July 2016
Resolved
Required to complete drills, pre departure checks, and lifesaving inspections.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2016
Resolution: Inspections/drills completed and logged.