Records from 2006 to 2026. Most recent: inspection, 9 July 2026.
Inspection history · 47
9 July 2026
COC-TVE Renew · PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8433512
9 July 2025
COC-TVE Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8174037
4 June 2025
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8152276
12 April 2025
Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8110508
22 November 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8038880
11 July 2024
PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7950139
6 July 2023
COC-TVE Annual · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7725550
5 July 2022
COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7496803
10 May 2021
COC-TVE Annual · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7190809
27 January 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7132593
24 January 2021
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7130979
19 June 2020
PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6978073
20 April 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6941363
11 March 2020
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6924712
4 June 2019
Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6704665
3 June 2019
COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6702335
19 May 2019
COC-TVE Annual · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6684102
11 June 2018
COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6426150
28 February 2018
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6363565
2 June 2017
COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6161786
21 February 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6091819
11 May 2016
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5874589
10 February 2016
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5812971
4 June 2014
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4879738
24 May 2014
ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4856702
17 July 2012
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4382195
16 July 2012
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4378457
7 September 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4138081
6 September 2011
Ballast Water Examination · COC-TVE Annual · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4130866
6 September 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4138307
6 September 2011
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4140228
17 January 2011
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3931740
5 January 2011
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3921855
5 January 2011
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3921880
1 December 2010
ISPS I Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3902040
27 November 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3897331
27 November 2010
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3899486
27 January 2010
Ballast Water Examination · ISPS I Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3670696
27 January 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3670698
11 June 2008
Ballast Water Examination · COC-TVE Renew · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3229165
2 May 2007
Ballast Water Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2920750
30 April 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2919352
21 August 2006
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2754796
1 June 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2667328
22 May 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2655879
13 April 2006
MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · COC-TVE Renew · MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2619492
12 April 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2618100
14 - Pollution Prevention › 146 - MARPOL Annex VI › Operational procedures for engines or equipment
Issued 11 July 2024
Resolved
Within three months after the end of each calendar year, the ship shall report to its Administration, or any organization duly authorized by it, the attained annual operational CII via electronic communication & using standardized format to be developed by the Organization. Vessel did not report its CII for calendar year 2023.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 10 August 2024
Resolved 12 July 2024
Resolution: At the time of the inspection, Master was unable to provide part II of the SEEMP to verify compliance of regulation 28.2 and CII rating. Company has since provided the requested documents dating 09MAY24 attesting the vessel is in complaince.
Electrical › Electric Generation Source (service) › Generator
Issued 19 May 2014
Resolved
1430: The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Pin hole leaks present at three generator cooling lines. 74 SOLAS (09) I/11; 40(a)(c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 June 2014
Resolution: RECEIVED SATISFACTORY CLASS REPORT FROM BV THAT THE SHIPS CREW MADE SATISFACTORY REPAIRS TO THE 3 GENERATOR COOLING LINES.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 19 May 2014
Resolved
1430: The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Oil leaking pass the inspection cover gasket on star air receiver. 74 SOLAS (09) I/11; 10(c)
Action required: 705 - Other - as specified
Resolved 24 May 2014
Resolution: Gasket on receiver was replaced.
Deck/Cargo › Inert Gas System › Scrubber Tower
Issued 19 May 2014
Resolved
1899: The protection of the cargo tanks shall be achieved by a fixed inert gas system in accordance with the requirements of the Fire Safety Systems Code. Low flow pressure alarm did not cause auto shut down. 74 SOLAS (04) & FSS Code 15.2.4.3.3; 10(c)
Action required: 705 - Other - as specified
Resolved 24 May 2014
Resolution: Vessel engineer corrected alam wiring.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 19 May 2014
Resolved
0999: Equip each fuel oil or bulk lubricated oil vent, overflow or fill pipe during oil transfer operations with a portable container of at least 5 US gallons capacity. Fill pipe flange was not over containment. 33CFR155.320; 10(c)
Action required: 705 - Other - as specified
Resolved 10 February 2016
Resolution: Vessel crew placed a 5 US gallon bucket under connection.
Documentation › Logs/Records › Declaration of Inspection
Issued 19 May 2014
Resolved
0999: No person may transfer oil or hazardous material to or from a vessel unless each person in charge has filled out and signed the declaration of inspection. Person in charge on vessel did not properly fill out Declaration of Inspection. 33CFR 156.150; 10(c)
Action required: 705 - Other - as specified
Resolved 24 May 2014
Resolution: Chief Engineer signed DOI.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 14 July 2012
Resolved
Echo- depth sounder was reported as not functional prior to departure. LOD outbound granted by CORMS PSC.
Condition: Improper/Lack of Maintenance
Due 25 July 2012
Resolved 19 July 2012
Resolution: Recieved tech report from vessel stating that satisfactory repairs have been made.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 6 September 2011
Resolved
1499-Other(Prop. & Aux. Machinery)- Each bunker line transfer pipe must be tested annually and not leak under static liquid pressure at least 1.5 times max allowable working pressure. Vessel conducted test, however, air was used as medium. Vessel is prohibited from conducting bunkering operations in US waters until properly tested and written documentation is provided to US Coast Guard. 33CFR155.8
Action required: 703 - Prior to bunkering operations
Due 6 September 2011
Resolved 8 September 2011
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. Bunker line was hydrostatically tested to 6 bar.
Engineering › Diesel Engine (propulsion-direct drive) › Charge Air Cooling
Issued 6 September 2011
Resolved
The vessel experienced a propulsion irregularity while in the Mississippi River.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 September 2011
Resolved 8 September 2011
Resolution: Received, reviewed and accepted class report from BV stating the main engine air scavengers were cleaned on all cylinders and water coolers cleaned and found satisfactory.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 2 May 2007
Resolved
Vessel's personnel unable to test required high level alarm (46 CFR 39.20-7C). Vessel is required to submit a report attesting to the high level alarm prior to loading of cargo, within seven days, from the classification society.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2007
Resolved 3 May 2007
Resolution: Received satisfactory class report attesting to the operation of the high level alarms.
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 30 April 2007
Resolved
The vessel reported that the IGS O2 sensor is malfunctioning. The vessel is required to submit temporary procedures that have been approved by class to insure the cargo tanks maintain a safe inerted atmosphere, prior to entry into port.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 1 May 2007