MAURY USCG vessel records Sign in
← All vessels

TAVROPOS

TAVROPOS is a 2006 tank ship. The Coast Guard has recorded 47 inspections since 2006, most recently in July 2026, along with 11 deficiencies and 10 operational controls.

Records from 2006 to 2026. Most recent: inspection, 9 July 2026.

Built
2006
Last inspected
9 July 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9307334 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
812484
Flag
LIBERIA
—
Maury page id
psix-812484

Inspections, by type

…with no type recorded16
Years with a record 18 calendar years (2006–2026)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it16707 - Convention (Subpart B), Net Ton
61204 - Dead Weight, Metric Ton
72605 - Displacement, Metric Ton
35711 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ATLAS Towing Vessel · MISLE 487419 · 17 January 2011 · activity 3931740

Inspection history · 47

9 July 2026 COC-TVE Renew · PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8433512
9 July 2025 COC-TVE Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8174037
4 June 2025 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8152276
12 April 2025 Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8110508
22 November 2024 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8038880
11 July 2024 PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7950139
6 July 2023 COC-TVE Annual · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7725550
5 July 2022 COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7496803
10 May 2021 COC-TVE Annual · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7190809
27 January 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7132593
24 January 2021 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7130979
19 June 2020 PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6978073
20 April 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6941363
11 March 2020 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6924712
4 June 2019 Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6704665
3 June 2019 COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6702335
19 May 2019 COC-TVE Annual · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6684102
11 June 2018 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6426150
28 February 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6363565
2 June 2017 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6161786
21 February 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6091819
11 May 2016 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5874589
10 February 2016 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5812971
4 June 2014 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4879738
24 May 2014 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4856702
17 July 2012 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4382195
16 July 2012 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4378457
7 September 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4138081
6 September 2011 Ballast Water Examination · COC-TVE Annual · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4130866
6 September 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4138307
6 September 2011 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4140228
17 January 2011 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3931740
5 January 2011 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3921855
5 January 2011 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3921880
1 December 2010 ISPS I Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3902040
27 November 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3897331
27 November 2010 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3899486
27 January 2010 Ballast Water Examination · ISPS I Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3670696
27 January 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3670698
11 June 2008 Ballast Water Examination · COC-TVE Renew · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3229165
2 May 2007 Ballast Water Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2920750
30 April 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2919352
21 August 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2754796
1 June 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2667328
22 May 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2655879
13 April 2006 MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · COC-TVE Renew · MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2619492
12 April 2006 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2618100

Deficiency record · 11

14 - Pollution Prevention › 146 - MARPOL Annex VI › Operational procedures for engines or equipment
Issued 11 July 2024 Resolved
Within three months after the end of each calendar year, the ship shall report to its Administration, or any organization duly authorized by it, the attained annual operational CII via electronic communication & using standardized format to be developed by the Organization. Vessel did not report its CII for calendar year 2023.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 10 August 2024
Resolved 12 July 2024
Resolution: At the time of the inspection, Master was unable to provide part II of the SEEMP to verify compliance of regulation 28.2 and CII rating. Company has since provided the requested documents dating 09MAY24 attesting the vessel is in complaince.
Electrical › Electric Generation Source (service) › Generator
Issued 19 May 2014 Resolved
1430: The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Pin hole leaks present at three generator cooling lines. 74 SOLAS (09) I/11; 40(a)(c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 June 2014
Resolution: RECEIVED SATISFACTORY CLASS REPORT FROM BV THAT THE SHIPS CREW MADE SATISFACTORY REPAIRS TO THE 3 GENERATOR COOLING LINES.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 19 May 2014 Resolved
1430: The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Oil leaking pass the inspection cover gasket on star air receiver. 74 SOLAS (09) I/11; 10(c)
Action required: 705 - Other - as specified
Resolved 24 May 2014
Resolution: Gasket on receiver was replaced.
Deck/Cargo › Inert Gas System › Scrubber Tower
Issued 19 May 2014 Resolved
1899: The protection of the cargo tanks shall be achieved by a fixed inert gas system in accordance with the requirements of the Fire Safety Systems Code. Low flow pressure alarm did not cause auto shut down. 74 SOLAS (04) & FSS Code 15.2.4.3.3; 10(c)
Action required: 705 - Other - as specified
Resolved 24 May 2014
Resolution: Vessel engineer corrected alam wiring.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 19 May 2014 Resolved
0999: Equip each fuel oil or bulk lubricated oil vent, overflow or fill pipe during oil transfer operations with a portable container of at least 5 US gallons capacity. Fill pipe flange was not over containment. 33CFR155.320; 10(c)
Action required: 705 - Other - as specified
Resolved 10 February 2016
Resolution: Vessel crew placed a 5 US gallon bucket under connection.
Documentation › Logs/Records › Declaration of Inspection
Issued 19 May 2014 Resolved
0999: No person may transfer oil or hazardous material to or from a vessel unless each person in charge has filled out and signed the declaration of inspection. Person in charge on vessel did not properly fill out Declaration of Inspection. 33CFR 156.150; 10(c)
Action required: 705 - Other - as specified
Resolved 24 May 2014
Resolution: Chief Engineer signed DOI.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 14 July 2012 Resolved
Echo- depth sounder was reported as not functional prior to departure. LOD outbound granted by CORMS PSC.
Condition: Improper/Lack of Maintenance
Due 25 July 2012
Resolved 19 July 2012
Resolution: Recieved tech report from vessel stating that satisfactory repairs have been made.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 6 September 2011 Resolved
1499-Other(Prop. & Aux. Machinery)- Each bunker line transfer pipe must be tested annually and not leak under static liquid pressure at least 1.5 times max allowable working pressure. Vessel conducted test, however, air was used as medium. Vessel is prohibited from conducting bunkering operations in US waters until properly tested and written documentation is provided to US Coast Guard. 33CFR155.8
Action required: 703 - Prior to bunkering operations
Due 6 September 2011
Resolved 8 September 2011
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. Bunker line was hydrostatically tested to 6 bar.
Engineering › Diesel Engine (propulsion-direct drive) › Charge Air Cooling
Issued 6 September 2011 Resolved
The vessel experienced a propulsion irregularity while in the Mississippi River.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 September 2011
Resolved 8 September 2011
Resolution: Received, reviewed and accepted class report from BV stating the main engine air scavengers were cleaned on all cylinders and water coolers cleaned and found satisfactory.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 2 May 2007 Resolved
Vessel's personnel unable to test required high level alarm (46 CFR 39.20-7C). Vessel is required to submit a report attesting to the high level alarm prior to loading of cargo, within seven days, from the classification society.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2007
Resolved 3 May 2007
Resolution: Received satisfactory class report attesting to the operation of the high level alarms.
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 30 April 2007 Resolved
The vessel reported that the IGS O2 sensor is malfunctioning. The vessel is required to submit temporary procedures that have been approved by class to insure the cargo tanks maintain a safe inerted atmosphere, prior to entry into port.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 1 May 2007

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.