GRAND ORION is a freight ship. The Coast Guard has recorded 20 inspections since 2006, most recently in July 2026, along with 8 deficiencies and 3 operational controls.

Records from 2006 to 2026. Most recent: inspection, 31 July 2026.

Built
Not recorded
Last inspected
31 July 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9303194 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7B3229
812520
Flag
PANAMA
—
Maury page id
psix-812520

Inspections, by type

…with no type recorded4
Years with a record 14 calendar years (2006–2026)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it17766 - Convention (Subpart B), Net Ton
59217 - Convention (Subpart B), Gross Ton
18312 - Dead Weight, Metric Ton
35002 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

31 July 2026 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8447903
12 December 2025 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8279378
17 November 2022 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7592544
10 May 2022 PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7444381
19 December 2021 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7370396
6 December 2021 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7363548
29 November 2021 PSC B · MARPOL Annex VI Survey · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7358343
19 April 2021 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7178495
16 November 2020 Deficiency Check · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7095934
13 May 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6682958
15 November 2018 COE-Dockside
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6581495
17 January 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6334666
21 December 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6057907
28 October 2015 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5751918
26 June 2012 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4357016
8 May 2009 ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3468652
10 March 2008 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3158039
10 January 2007 Ballast Water Examination · Random ISPS/MTSA/PSC · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2853850
12 April 2006 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2622864
11 April 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2622667

Deficiency record · 8

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 July 2026 Resolved
All electrical apparatus shall be constructed and so installed as to not cause injury when handled or touched in a normal manner. PSCO observed dead-end wires with plastic caps attached to the ends, on the bridge and in the radio room. 75 SOLAS(04) II-1/45.1.3
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2026
Resolved 5 August 2026
Resolution: Received satisfactory class report attesting to the repair of all electrical apparatus'.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 31 July 2026 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed leaking fuel oil from the NO.1 cylinder for the main engine. Vessel crew replaced the gasket, stopping the leak. 78 SOLAS(20)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 July 2026
Resolved 31 July 2026
Resolution: Vessel crew replaced the gasket, stopping the leak.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 November 2020 Resolved
07106: The activation of any detector or manually operated call point shall indicate a visual and audible fire signal at the control panel and indicating units. While testing fire detection system, PSCO observed that the visual indicators in the engine room were not working by the MDG's and purifiers. 74 SOLAS (04)II-2/7.2.2 / FSS Code 9.2.5.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2020
Resolution: Deficiencies rectified to the satisfaction of attending class surveyor.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 16 November 2020 Resolved
07123: Ships shall be provided with fire pumps, fire mains, hydrants, and hoses complying with the applicable requirements of this regulation. Vessels crew wasn't able to demonstrate proper operations of the emergency fire pump. 74 SOLAS (04) II-2/10.2
Action required: 10 - Deficiency Rectified
Resolved 16 November 2020
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 May 2019 Resolved
DIESEL OIL TRANSFER PUMP HAD ACCUMULATED AN ESTIMATED 01 GALLON OF DIESEL OIL WITHIN THE CONTAINMENT AREA
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 May 2019
Resolved 13 May 2019
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 21 December 2016 Resolved
Fire fighting systems shall be maintained and ready for use. Emergency fire pump did not start when tested. Engineering cre fixed pump during exam. 74 solas (14) II-2/14.1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 December 2016
Resolved 21 December 2016
Resolution: Corrected on the spot.
Construction/Loadline › Hull › Longitudinal Frame
Issued 26 June 2012 Resolved
Whenever an accident occurs to a ship or a defect is discovered, either of which affects the safety of the ship or completeness of its lifesaving appliances, or other equipment, the master or owner of the ship shall report at the earliest opportunity to administration. During hull inspection, significant denting was discovered on the stbd bow hull that was not reported. 74SOLAS(09) reg 1-11.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 June 2012
Resolution: Class report submitted stating that all damaged and temporarily repaired parts were found to be in good working order, and that the damage will be repaired during a 23 FEB 2014 dry-dock.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 26 June 2012 Resolved
The normal equipment of every lifeboat shall consist of a food ration totalling not less than 10,000 KJ for each person the lifeboat can accomodate. 18 total food rations missing on board lifeboats.
Due 26 June 2012
Resolved 26 June 2012
Resolution: Invoice received by agent attesting to the purchase of 18 new food ratiosn that are now onboard the vessel. Vessel has been allowed to leave the port.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.