07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 February 2026
Resolved
Each vessel must be equipped with one self-priming power-driven fire pump. Unable to test fire pump, prove operation prior to movement.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 March 2026
Resolution: Witnessed operation, all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 February 2026
Resolved
Each bilge system must comply with 46 CFR subpart F. Unable to test bilge system, prove operation prior to movement.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 March 2026
Resolution: Witnessed operation, all sat
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 4 February 2026
Resolved
Potable water was inoperable, repair prior to movement.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 March 2026
Resolution: Witnessed operation, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 February 2026
Resolved
Systems containing oil - tank must be fitted with a positive shutoff valve. Handle was missing and the valve was frozen, repair prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 March 2026
Resolution: Witness operation, all sat
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 4 February 2026
Resolved
Rudder angle indicator was inoperable, prove operation prior to movement.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 March 2026
Resolution: Witnessed operation, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 4 February 2026
Resolved
Ensure proper operation of rescue boat engines. Engine would not run, prove operations prior to movement.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 March 2026
Resolution: Witnessed operation, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 4 February 2026
Resolved
Each fall used with a launching appliance must be renewed because of deterioration or not more than 5 years. Falls have not been replaced in more than 5 years. Conduct weight test after fall has been renewed.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2026
Resolved 3 March 2026
Resolution: Witnessed test after new wire was installed, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 4 February 2026
Resolved
Immersion suits must be marked with vessel name and have a light attached. Some suits were missing lights & name.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2026
Resolved 3 March 2026
Resolution: Corrected
08 - Alarms › N/A - No Subsystem › General alarm
Issued 4 February 2026
Resolved
Each general alarm must be identified by red letters 1/2" high that state "GENERAL ALARM - WHEN BELL RINGS GO TO YOUR STATION". Two locations were missing signage.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2026
Resolved 10 February 2026
Resolution: Observed in place
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 February 2026
Resolved
Flex hose was missing double hose clamps in indicated by CG inspector during inspection.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2026
Resolved 3 March 2026
Resolution: Installed
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 4 February 2026
Resolved
All rotating machinery capable of injuring personnel must be provided with adequate covers or guards. Missing guard on machinery for bowtruster.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2026
Resolved 3 March 2026
Resolution: Installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 February 2026
Resolved
Flame impingement bowls were missing from the fuel filters.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2026
Resolved 3 March 2026
Resolution: Installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 February 2026
Resolved
Secure fuel leak on transfer valve and coolant leak on starboard generator.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2026
Resolved 3 March 2026
Resolution: Valve replaced and leak secured
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 4 February 2026
Resolved
Marking for emergency exit from engine room was missing.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2026
Resolved 10 February 2026
Resolution: Installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 February 2026
No resolution recorded
Handle for watertight door leading in the E/R needs to be adjusted. Correct prior to next drydock credit.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 February 2026
Resolved
Repair angle iron for deck support in bowthruster space. Correct prior to next drydock credit.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 13 March 2026
Resolution: repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 March 2025
Resolved
Electrical equipment on a vessel must be designed, installed and maintained to provide services necessary for safety under normal and emergency conditions. Port generator is not operating properly. Repair to satisfaction of CG marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 March 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 26 March 2025
Resolved
There must be at least one toilet, one washbasin and one shower or bathtub for every eight or fewer crew members. Potable water is inoperable and needs to be repaired prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 March 2025
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 26 March 2025
Resolved
Each OSV, must carry an immersion suit of suitable size for each person on board. Vessel required to have 36 immersion suits on board. Only 28 immersion suits were accounted for. Vessel is restricted to no more than 3 crew members and 25 offshore workers when operating less than 12 hours in a 24 hour period.
Action required: 705 - Other - as specified
Resolved 7 April 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 March 2025
Resolved
Non-metallic flexible hose must be in accordance with SAE J1942 and may be installed only in lube oil and fuel systems. Starboard generator has improper fuel hoses. Replace with required hoses.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 7 April 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 March 2025
Resolved
Wiring in aft port corner of wheelhouse must be properly secured with metallic support.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 10 April 2025
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 26 March 2025
Resolved
On each cooking appliance, sea rails, with suitable barrier to prevent accidental movement of cooking pots, must be installed. Vessel is missing sea rails.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 7 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 26 March 2025
Resolved
Each rescue boat must be marked with Type II retro-reflective material approved under subpart 164.018. The arrangement of the retro-reflective material must comply with IMO Resolution A.658(18). Vessel does not have retro-reflective material on bottom of vessel, which is required for non-self righting boats.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 10 April 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 January 2025
Resolved
General alarm strobe light in engine space has loose wiring. Properly secure wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 10 April 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 January 2025
Resolved
Lube oil pressure switch wiring is exposed. Properly secure wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 7 April 2025
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 31 January 2024
Resolved
The following vessels must have on board a properly installed, operational Coast Guard type approved AIS class A device: self-propelled vessel of 65 feet or more, engaged in commercial service. Vessel's AIS is inoperable.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 February 2024
Resolution: AIS now operable
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 31 January 2024
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. The alcohol testing devices are expired.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 February 2024
Resolution: Alcohol testing devices were replaced
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 31 January 2024
Resolved
Visible and audible alarms must be installed at the pilothouse to indicate engine and bilge alarms. Pilothouse does not indicate alarms.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 30 April 2024
Resolution: Witnessed visual and audible alarm on bridge for both bilge alarms.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 January 2024
Resolved
Dual navigation light sources; must have duplicate light sources for the side, masthead and stern lights. Masthead backup light was inoperable.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 1 March 2024
Resolution: Masthead lights were replaced and are now operational.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 31 January 2024
Resolved
An OSV must have an immersion suit of appropriate size for each person on board. Vessel has 22 immersion suits on board, missing 14.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 2 February 2024
Resolution: 14 immersion suits were added on board, total number is 36
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 January 2024
Resolved
Each life jacket must have a light attached to the front shoulder. 18 of 38 life jacket lights were expired.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 2 February 2024
Resolution: Lights were installed on lifejackets
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 January 2024
Resolved
Emergency lighting must automatically actuate upon failure of main lighting. 03 emergency lights were inop.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 1 March 2024
Resolution: all emergency lights are operational
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 January 2024
Resolved
Each cable and wire must be supported to prevent chafing and other damage. Change out plastic supporting devices to noncombustible supports.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 1 March 2024
Resolution: wire supports were replaced with metal devices
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 January 2024
Resolved
Each portable fire extinguisher must be marked with a number and the site of its stowage must be marked with a corresponding number at least .5 inch high. Fire extinguishers are not numbered.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 1 March 2024
Resolution: Fire extinguishers and locations are numbered
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 31 January 2024
Resolved
Each CO2 alarm must be conspicuously marked "WHEN ALARM SOUNDS VACATE AT ONCE. CARBON DIOXIDE OR CLEAN AGENT BEING RELEASED". CO2 alarms are not marked.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 30 April 2024
Resolution: Verified posting of signs in vicinity of alarms in E/R
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 24 January 2023
Resolved
Each cargo vessel must carry an immersion suit of an appropriate size for each person on board. In addition, enough immersions suits are required at watch stations equal to the number of persons normally on watch in or assigned to those locations at a time. Vessel has 30 immersion suits and needs additional 8 immersions suits. 46 CFR 199.273 (b)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 10 February 2023
Resolution: Verified vessel has 38 immersion suits on board.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 24 January 2023
Resolved
Each immersion suit must be marked in such a way as to identify the person or vessel to which it belongs. The immersion suits on board were not marked. 46 CFR 199.70 (c)(3)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 10 February 2023
Resolution: Verified all immersion suits were labeled with the vessel's name.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 24 January 2023
Resolved
Each vessel must have posters or signs displayed in the vicinity of each survival craft that give relevant instructions on launching. Vessel did not have any posted instructions on how to launch life rafts. 46 CFR 199.90
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 10 February 2023
Resolution: Verified all three liferaft launching locations had launching intructions posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 January 2023
Resolved
Starboard lifebuoy on the main deck has an inoperable waterlight. 46 CFR 199.70 (a)(3)(ii)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 10 February 2023
Resolution: Verified the waterlight was operable.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 January 2023
Resolved
Dual navigation light sources; must have duplicate light sources for the side, masthead and stern lights. Portside backup light was inoperable. 46 CFR 111.75-17 (c)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 10 February 2023
Resolution: Verified portside navigation backup light was operational.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 24 January 2023
Resolved
A fire pump must be capable of both manual operation at the pump and if a remote operating station is fitted, operation at that station. Could not verify proper operation of the fire monitor on the upper deck. 46 CFR 132.120 (k)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 10 February 2023
Resolution: Verified that fire pump was started on the bridge with satisfactory output from the monitor.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 January 2023
Resolved
Each fire station must be equipped with a spanner wrench suitable for use on the hose there. The spanner wrench at the forward fire station is broken. 46 CFR 132.130 (f)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 10 February 2023
Resolution: Verified spanner wrench was replaced.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 24 January 2023
Resolved
Visible and audible alarms must be installed at the pilothouse to indicate engine and bilge alarms. Pilothouse does not indicate alarms. 46 CFR 130.460 (a)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 10 February 2023
Resolution: Verified alarms were operable and identifiable on the bridge.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 24 January 2023
Resolved
Each watertight door in a bulkhead must be marked on both sides. Mark watertight door in accordance with cite. 46 CFR 131.893
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 10 February 2023
Resolution: Verified all three watertight doors were labeled on both sides.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 January 2023
Resolved
Electrical equipment shall protect crew and persons on board from electrical hazards. Two junction boxes were in poor condition; bow thruster and water heater space. 46 CFR 129.200 (b)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 10 February 2023
Resolution: Verified junction boxes no longer exposed an electrical hazard
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 January 2023
Resolved
Employees must maintain records of chemical tests and provide records to the Coast Guard upon request. Provide list of employees & company testing program procedures. 46 CFR 16.260
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 10 February 2023
Resolution: Verified drug and alocohol program was in proper order.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 21 March 2022
Resolved
Vessel's COI requires 37 immersion suites. Vessel only had 30 on board. Vessel is required to outfit the vessel with 7 additional immersion suites. Vessel's total persons allowed will be reduced to 30 until the immersion suits are added.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 March 2022
Resolution: reduced offshore workers
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 21 March 2022
Resolved
Steering gear tests are required to be logged. No steering gear tests have been logged.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2022
Resolution: complete
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 21 March 2022
Resolved
Complete and log abandon ship drills in accordance with 46CFR131.530.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2022
Resolution: complete
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 21 March 2022
Resolved
Complete and log fire drills in accordance with 46CFR131.535.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2022
Resolution: complete
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 21 March 2022
Resolved
Complete and log weekly, monthly, quarterly drills in accordance with 46CFR131.560.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2022
Resolution: complete
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 21 March 2022
Resolved
Rudder angle indicator had a 10 degree deviation between full rudder pot and starboard. Rudder angle indicator requires calibration.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 May 2022
Resolution: Tested satisfactory
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 21 March 2022
Resolved
Provide 500 ft of 3' manila axillary line for the line throwing gun.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2022
Resolution: Complete
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 21 March 2022
Resolved
Clean hydraulic fluid from bilge in bow thruster space to allow for bilge suction testing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2022
Resolution: Complete
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 21 March 2022
Resolved
Provide a signed copy of the endorsed Load Line Certificate testifying to the 2022 annual survey.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 March 2022
Resolution: Received a signed copy
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 March 2022
Resolved
Generator prime movers are required to be equipped with a over speed safety device. The port generator over speed safety devise did not operate over 65 htz.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2022
Resolution: complete
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 March 2022
Resolved
Port and Starboard generator winding covers were not bolted down securing them in place. Ensure cover is bolted in place to prevent shifting.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2022
Resolution: Complete
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 March 2022
Resolved
Starboard main engine local RPM gauge was not operating. Provide a functional RPM gauge.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2022
Resolution: Cleared onscene
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 March 2022
Resolved
Repair bow thruster pressure regulator switch for bow thruster prim mover gear box.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 April 2022
Resolution: Cleared onscene
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 21 March 2022
Resolved
Conduct an anchor drill.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 April 2022
Resolution: Cleared onscene
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 21 March 2022
Resolved
Provide updated navigation publications. Tide Tables, Light List and Coast Pilot are all out of date.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2022
Resolution: Complete
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 21 March 2022
Resolved
Vessels alarm panel is displaying a fire alarm, port gear oil pressure alarm andstbd generator water temp alarm. Vessel lost generator while attempting to get underway for drills. Captain claims the shutdown was due to the alarm panel issue.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 April 2022
Resolution: Cleared onscene
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 December 2020
Resolved
missing one waterlight
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 January 2021
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 December 2020
Resolved
Replace float free EPIRB housing
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 January 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 15 December 2020
Resolved
Provide a copy of ABS Class and LL Certificates
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 15 December 2020
Resolved
Attach painter to weak link for 12 person life raft
Action required: 10 - Deficiency Rectified
Resolved 8 January 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 December 2020
Resolved
Make wire penetration in engine room watertight bulkhead watertight
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 December 2020
Resolved
Provide flame bowls for all non-metallic fuel filters
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 January 2021
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 15 December 2020
Resolved
Replace e-light over port main engine
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 January 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 December 2020
Resolved
M/V DANIELLE MILLER is overdue for its second annual inspection; COI was issued on 16MAY2018.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 December 2020
Resolved 11 January 2021
Resolution: Enforcement action taken.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 18 September 2019
Resolved
Annual survey was not complete
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 December 2020
Resolution: Verified certificate during inspection
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 September 2019
Resolved
Provide Letter of Intent and General Permit
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 December 2020
Resolution: Verified General Permit and Letter of Intent during inspection
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 18 September 2019
Resolved
Provide instructions for the use of the emergency steering system
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 December 2020
Resolution: Verified emergency instructions
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 15 June 2018
Resolved
Partially installed Portable Accomodation Modules are not to be utilized by crew or offshore workers prior to satisfactory inspection by CG Marine Inspector and the COI is ammended to reflect approval.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 July 2018
Resolved 22 July 2018
Resolution: Finalized Installation