Records from 2006 to 2026. Most recent: inspection, 6 August 2026.
Documentation record
Registered dimensions (L × B × D)491.8 ft × 72.0 ft × 41.0 ft
Registered tonnagegross 9,746 / net 9,746
ITC dimensions (L × B × D)491.8 ft × 72.0 ft × 41.0 ft
ITC tonnagegross 10,840 / net 5,625
BuilderUSCS ATB LLC · SPARROWS POINT, MD, UNITED STATES · built 2007
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 27 January 2026 · expires 28 February 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5625 - Convention (Subpart B), Net Ton
9746 - Regulatory (Subpart C or D), Net Ton
19999 - Dead Weight, Ton
10840 - Convention (Subpart B), Gross Ton
9746 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 49
6 August 2026
Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8457336
17 November 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8269631
9 September 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8230116
17 April 2025
Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8113245
31 March 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8102773
19 August 2024
MTSA Verification · MARPOL Annex II Examination · Periodic Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7965980
26 July 2024
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7967637
2 June 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7929266
14 August 2023
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7769152
28 February 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7643424
17 February 2023
Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7638402
11 February 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7635408
8 July 2022
MARPOL Annex I Examination · Internal Structural Exam · Drydock Exam · Deficiency Check · MARPOL Annex II Examination · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7479072
21 June 2022
COI Inspection · MTSA/ISPS Verification · Drydock Extension · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7477552
15 June 2022
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7478443
21 September 2021
Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7313006
26 July 2021
MTSA Verification · Administrative Inspection · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7268523
14 April 2021
Bulk Liquid Transfer Monitor
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7175364
25 January 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7130127
2 September 2020
Periodic Inspection · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7048298
20 April 2020
Administrative Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6948480
17 September 2019
MARPOL Annex II Examination · MTSA Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6814750
9 July 2018
Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex II Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6473496
9 May 2017
Internal Structural Exam · Drydock Exam · MARPOL Annex I Examination · COI Inspection · MARPOL Annex II Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6141972
27 October 2016
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6030948
13 October 2016
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6023731
13 October 2015
Periodic Inspection · MTSA/ISPS Verification · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5743427
18 May 2015
Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5130388
10 October 2014
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5002758
22 October 2013
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4739207
11 August 2013
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4681543
5 September 2012
Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4433327
15 August 2012
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4411545
12 June 2012
Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4341567
29 June 2011
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4060598
21 December 2010
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3914377
21 July 2010
MARPOL Annex I Examination · MARPOL Annex II Examination · MTSA Verification · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3802093
27 May 2010
Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3747004
3 February 2010
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3675041
8 September 2009
MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3589430
23 July 2009
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3544242
24 February 2009
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3423244
25 September 2008
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3332375
23 September 2008
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3331133
8 July 2008
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3261649
18 March 2008
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3167033
21 February 2008
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3151219
29 January 2008
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3138123
25 January 2006
Hull Examination · Initial Certification · MTSA Verification · Internal Structural Exam · Construction Oversight · Cargo Tank Internal · Security Plan Review - VSP
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2927631
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 9 September 2025
Resolved
EACH HOSE MUST BE MARKED IWTH ONE OF THE FOLLOWING: "OIL SERVICE" OR FOR HAZARDOUS MARTERIALS, THE WORDS "HAZMAT SERVICE - SEE LIST. ALL HOSES NOT MARKED.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 9 September 2025
Resolution: Hoses stamped while inspection was still happening.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 9 September 2025
Resolved
EACH HOSE ALSO MUST BE MARKED WITH THE FOLLOWING... MAXIMUM ALLOWABLE WORKING PRESSURE. ALL HOSES NOT MARKED.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 9 September 2025
Resolution: Hoses stamped while inspection was still ongoing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 September 2022
Resolved
Pressure vessels shall be designed, constructed, and inspected in accordance with section VIII of the AMSE Boiler and Pressure Vessel Code. Both start air receivers have several pits exceeding the allowable limit. Repair pits to the ASME VIII standard or replace the receivers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2022
Resolved 14 October 2022
Resolution: Revceived report illustrating the air receivers were repaired in accordance with ASME standards.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 15 June 2022
Resolved
Vessel's Thermal Fluid Heater suffered a leak due to corrosion located at the bottom of the tank.
Vessel is required to affect repairs to the thermal fluid heater, test all safety, hydrostatic test/pressure test the tank/repair to the satisfaction of the attending MI/surveyor.
Vessel is restricted prior to carrying cargo that needs to be heated.
Action required: 705 - Other - as specified
Resolved 13 September 2022
Resolution: Tank replaced with new UPV
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 13 October 2016
Resolved
All cargo/vapor piping and associated hatch coaming should be vapor tight. CG MI's indentified vapor leakage in the #3P vapor piping and #2 P tank hatch. Prove vapor tightness to attending MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 27 October 2016
Resolution: Vessel's Chief Mate replaced applicable gaskets on #3 Port vapor piping and #2 Port Tank Hatch. Vessel will ensure system vapor tightness on following voyage according to vessel's procedures.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 October 2016
Resolved
Remove dead-ended wiring in machinery pace above air receivers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 27 October 2016
Resolution: Vessel removed dead-end wiring in machinery space above air receiver
Electrical › Electrical Distribution System (service) › Switchboard
Issued 13 October 2016
Resolved
Replace soft blank in electrical panel in machinery space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 27 October 2016
Resolution: Soft blank was replaced with steel blank on electrical panel in machinery space.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 13 October 2016
Resolved
Remove excessive trash and dead-ended wiring behind/within switchboard in machinery space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 27 October 2016
Resolution: Trash and dead-end wiring removed from switchboard area in machinery space.
Engineering › Compressed Air System (start air) › Valve
Issued 13 October 2016
Resolved
Demonstrate proper operation of relief valves for air receivers in machinery space.
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 27 October 2016
Resolution: Air receiver relief valves replaced by vessel's engineers, proper operation demonstrated by engineers and verified by marine inspector.
Construction/Loadline › Markings › Load Line Mark
Issued 13 October 2016
Resolved
Permanantly affix loadline markings to both sides of vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 27 October 2016
Resolution: Load line observed by Marine Inspector to be properly affixed permanently by punch marks. Load line marked in contrasting color to hull
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 13 October 2016
Resolved
Verify vapor tightness on high/overfill alarm handles and forward vapor line P/V packing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 27 October 2016
Resolution: Chief Mate tightened High Level/Overfill handle seals to stop vapor leakage. Additionally replaced gasket on P/V vacuum side to restrict unintended air intake into vapor line. High Level/Overfill alarm tested to ensure good seal.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 13 October 2015
Resolved
The five Class 1/Division 1 fittings on the cargo tank high level alarms were not packed and sealed properly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 October 2015
Resolved 14 October 2015
Resolution: All five Class 1/Division 1 fitting were properly packed and sealed.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 10 October 2014
Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward. All vapor connection flange face and reducers are missing studs and existing studs are not permanently attached.
Due 10 November 2014
Resolved 3 November 2014
Resolution: Vessel provided picture of the permanent stud attached to all vapor connection flange face and reducers.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 10 October 2014
Resolved
Each ungrounded system must be provided with a suitable sensitive ground detection system which provides continuous indication of circuit status to ground. 240 Volt ground detection is not indicating a continuous circuit status.
Due 10 November 2014
Resolved 3 November 2014
Resolution: Received email with pictures and Marine Electrician service report stating the repairs made to the 240 Volt ground detection system.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 June 2012
Resolved
Provide machinery guards on generator belts in machinery room. 46 CFR 32.02-15.
Action required: 705 - Other - as specified
Due 14 September 2012
Resolved 12 September 2012
Resolution: Machinery guards adequately installed.
Electrical › Electrical Distribution System (service) › Switch
Issued 12 June 2012
Resolved
Missing label on one switchboard switch. 46 CFR 111.30-15(b)
Action required: 705 - Other - as specified
Due 22 August 2012
Resolved 25 July 2012
Resolution: Corrected to the satisfaction of the attending Marine Inspector.
Engineering › Electric Propulsion System › Wiring
Issued 12 June 2012
Resolved
Remove unused hanging wire on fuel system wiring. 46 CFR 111.60-17(a).
Action required: 705 - Other - as specified
Due 22 August 2012
Resolved 25 July 2012
Resolution: Corrected to the satisfaction of the attending Marine Inspector.
Engineering › Gasoline Engine (auxiliary) › Exhaust Piping (4 cycle)
Issued 12 June 2012
Resolved
Install lagging properly on exhaust piping on midship HPU. 46 CFR 58.10-5.
Action required: 705 - Other - as specified
Due 22 August 2012
Resolved 25 July 2012
Resolution: Corrected to the satisfaction of the attending Marine Inspector.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 12 June 2012
Resolved
Clean oil residue on aft end of midship HPU. 46 CFR 31.10-15(b)
Action required: 705 - Other - as specified
Due 22 August 2012
Resolved 25 July 2012
Resolution: Corrected to the satisfaction of the attending Marine Inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 June 2012
Resolved
Electrical wiring in vicinity of 2P cargo tank access is chafing and needs to be better guarded with chafing rings or some manner. 46 CFR 111.60-5.
Action required: 705 - Other - as specified
Due 22 August 2012
Resolved 25 July 2012
Resolution: Corrected to the satisfaction of the attending Marine Inspector.
Deck/Cargo › Cargo Heating › General
Issued 12 June 2012
Resolved
Replace two rusted valves on thermal fluid heater piping in vicinity of 2P cargo tank. 46 CFR 56.20
Action required: 705 - Other - as specified
Due 22 August 2012
Resolved 15 August 2012
Resolution: Vessel''s replaced two rusted cargo heating valves on deck, all sat.
Deck/Cargo › Cargo Heating › General
Issued 12 June 2012
Resolved
Replace 2P aft tank washing valve that is rusted. 46 CFR 56.20.
Action required: 705 - Other - as specified
Due 22 August 2012
Resolved 25 July 2012
Resolution: Corrected to the satisfaction of the attending Marine Inspector.
Deck/Cargo › Cargo Heating › General
Issued 21 July 2010
Resolved
Replace wasted 1S &5P thermal oil deck heater supply/return valves. Heater valves are deteriorated and need to be replaced.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 22 September 2010
Resolved 10 September 2010
Resolution: Received photos of new valves installed.
Deck/Cargo › Holds/Tanks › Cargo Tank Arrangement/Size
Issued 8 September 2009
Resolved
Vessel cargo tank internal inspection is overdue as a result of the 2yr intervals for carriage of phenol cargoes. Vessel rep stated barge will never carry phenol cargoes and will rqst via MSC that phenols be removed from CAA.
Action required: 705 - Other - as specified
Due 9 November 2009
Resolved 26 October 2009
Resolution: Amended COI condition of carriage to prohibit phenol cargoes.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 29 June 2006
Resolved
The radar cargo level indicator electrical equipment is not certified for use in Hazardous Locations. Until ATEX approved electrical equipment is certified to IEC standards, it may only be energized when the installed Nitrogen Inert Gas System is operational and maintaining an inert atmosphere within the cargo tanks. 12/23: extended 6 mos due to ongoing testing/approval
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 June 2008
Resolved 23 September 2008
Resolution: cleared based on approval letters, correspondance with MSC and photos showing the required labeling and cable penetration packings in the hazardous areas. Removed restriction from COI routes and conditions.