MAURY USCG vessel records
← All vessels

LARVIK

LARVIK is a 2006 tank ship. The Coast Guard has recorded 17 inspections since 2016, most recently in August 2025, along with 6 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 28 August 2025.

Built
2006
Last inspected
28 August 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 August 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9307346
813501
Flag
BAHAMAS, THE
Maury page id
psix-813501

Documentation record

Tonnage as PSIX records it16707 - Convention (Subpart B), Net Ton
72605 - Displacement, Metric Ton
61213 - Dead Weight, Metric Ton
35711 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

28 August 2025 Administrative Inspection · PSC B · COC-TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8217715
21 October 2024 PSC B
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8020979
23 August 2024 COC-TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7981606
27 September 2023 Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7799153
21 August 2023 COC-TVE Annual · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7771501
1 September 2022 COC-TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7548211
11 November 2021 COC-TVE Annual · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7347991
5 September 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7304551
22 March 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7160639
7 September 2020 PSC B · COC-TVE Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7049993
16 September 2019 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6809340
23 August 2018 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6520328
24 April 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6398707
10 February 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6353089
27 July 2017 Ballast Water Examination · ISPS III Exam · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6219038
31 July 2016 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5958055
25 January 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5802981

Deficiency record · 6

11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 23 August 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed port side rescue boat engine failure when testing the engine in astern. Engine died and thick black oil was observed leaking from exhaust. Engine was restarted after 15 minutes and thick white smoke with more oil came from exhaust. Engine RPMs were excessive and uncontrollable. 74 SOLAS (20) III/20.2 Code 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2024
Resolution: PSC NOLA received a class report from Lloyd's Register satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 August 2024 Resolved
Where the access to the emergency fire pump is by means of an airlock the administration may accept an arrangement with the door of the machinery space being of “A-60” class standard and the other door being at least steel, both reasonably gas tight, self closing and without holdback arrangements. Neither door to the emergency fire pump were self closing. 74 SOLAS (20) II-2/10.2.2.3.2.2 Code 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2024
Resolved 29 August 2024
Resolution: PSC NOLA received a class report from Lloyd's Register satisfying the requirement.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 August 2024 Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the organization. PSCO observed several deteriorated gaskets and missing bolts on conduit junction boxes on the cargo deck. 74 SOLAS (20) II-1/45.11 Code 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2024
Resolved 29 August 2024
Resolution: PSC NOLA received a class report from Lloyd's Register satisfying the requirement.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 27 September 2023 Resolved
33 CFR 151.2035 To discharge ballast water into the waters of the United States, the master, owner, operator, agent or person in charge of a vesel subject to 151.2025 of this part must either ensure that the ballast water meets the ballast water discharge standard in 151.2030(a), usa an AMS as described in 151.2025(a)(3), or ballast with water from a U.S. public water system, acording to the schedule in paragraph (b) of this section. Vessel is past its compliance dater per the implementaiton schedule in 33 CFR 151.2035(b). The vessel's installed BWMS system is inoperable. The vessel is not authorized to discharge untreated ballast into the waters of the U.S. without prior written authorization from the local COTP under the provisions of 33 CFR 151.2040(b).
Action required: 10 - Deficiency Rectified
Due 4 October 2023
Resolved 27 September 2023
Resolution: Prior to PSCO departure, technician completed repairs and the system is functional. See attached tecnician report.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 7 September 2020 Resolved
SOLAS(2004 CONS) CH. II-1 REG 44.2- EACH EMERGENCY GENERATING SET ARRANGED TO BE AUTOMATICALLY STARTED SHALL BE EQUIPPED WITH STARTING DEVICES WITH A STORED ENERGY CAPABILITY OF AT LEAST THREE CONSECUTIVE STARTS. EMERGENCY GENERATOR COULD NOT BE STARTED USING BATTERY POWER. 04114.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 September 2020
Resolved 7 September 2020
Resolution: PSCO witnessed installation of new battery and confirmed that charging system was SAT. Issued 10c.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 23 August 2018 Resolved
Code: 1710 The oil record book shall be kept in such a place as to be readily available for inspection at all reasonable times. Crew could not provide the Oil Record Book Part II. Cite: MARPOL I/ 36.7
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 August 2018
Resolved 23 August 2018
Resolution: Crew accurately logged previos cargo operations and began new Oil Record Book II for current cargo operations.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.