THOMAS J BROWN

Built
1962
Last inspected
25 February 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 25 February 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 13 calendar years (1997–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDP5838
Flag
UNITED STATES
Maury page id
psix-81423

Documentation record

Registered dimensions (L × B × D)60.6 ft × 18.8 ft × 8.1 ft
Registered tonnagegross 61 / net 42
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGLADDING-HEARN SHIPBLDG · SOMERSET MA, UNITED STATES · built 1962
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNORFOLK, VA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 25 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Regulatory (Subpart C or D), Gross Ton
42 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 15 inspections, each with its date, unit and type; 42 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 4 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BUCHANAN #34 Freight Barge · MISLE 1042567 · 31 August 2009 · activity 3601063FEENEY 26 Freight Barge · MISLE 47159 · 9 April 2001 · activity 183927B-254 Freight Barge · MISLE 97928 · 9 April 2001 · activity 183927NH 106 Freight Barge · MISLE 104684 · 9 April 2001 · activity 183927

Inspection history · 15

25 February 2026 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8314627
12 December 2024 COI Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8037811
26 August 2022 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7544020
14 July 2022 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7506497
21 July 2020 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7012674
1 October 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6552255
1 June 2017 Deficiency Check · Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6165930
14 February 2013 Deficiency Check · Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4537332
15 February 2012 Administration
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4245109
31 August 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3601063
1 March 2004 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2016410
5 October 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1073761
9 April 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 183927
18 October 2000 Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1055892
9 December 1997 Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1117743

Deficiency record · 42

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 February 2026 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be maintained to ensure proper operation. During the inspection, it was reported that a ship's service generator is prone to overheating under certain operational conditions. 46 CFR 143.205
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 March 2026
Resolution: Vsl removed service generator and will use battery bank as secondary source of power.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 February 2026 Resolved
New installations that are not replacements in kind must comply with the requirements of subpart C of this part. During the inspection, it was reported that the vsl primarily utilizes an unapproved Welder Generator as the secondary source of power. 46 CFR 143.205
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 March 2026
Resolution: Vsl removed welder generator and will use battery bank as secondary source of power.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 February 2026 Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. MI observed excessive oil in the bilge. 46 CFR 142.220(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 March 2026
Resolution: Oil was removed from the bilge.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 February 2026 Resolved
Electrical connections must be suitably installed to pre prevent from coming loose through vibration or accidental contact. MI observed extension cords used as permanent means for providing power to pilot house battery charger. 46 CFR 143.400(e)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 March 2026
Resolution: Extension cords were removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 February 2026 Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. MI observed loose and exposed wiring in the forepeak void. 46 CFR 143.400(e)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 March 2026
Resolution: Exposed wiring was removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 25 February 2026 Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. MI observed missing and inadequate insulation on the MDE turbocharger, and exhaust manifolds. 46 CFR 143.220(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2026
Resolved 5 March 2026
Resolution: Adequate insulation was pleaced on MDE turbocharger, and exhaust manifolds.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 February 2026 Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. MI observed loose overhead lighting fixtures in the aft machinery space as well as lighting fixtures that were being held together with zip ties. 46 CFR 143.400(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2026
Resolved 5 March 2026
Resolution: Lighting fixtured were reinstalled and zipties were removed from overhead lighting.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 February 2026 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an or essential system develops problems that require attention. MI observed that the alarm control panel in the pilothouse was troubleshooting. 46 CFR 143.230(a)
Action required: 10 - Deficiency Rectified
Due 25 February 2026
Resolved 25 February 2026
Resolution: New battery installed in panel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 February 2026 Resolved
Electrical components that pose an electrical hazard must be in an enclosure. MI identified exposed wiring in the aft fiddly distribution box. 46 CFR 143.400 (g)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2026
Resolved 5 March 2026
Resolution: Aft fiddly distribution Box was closed off.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 February 2026 Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. MI witnessed unattached junction box cover in aft fiddly. 46 CFR 143.400(e)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2026
Resolved 5 March 2026
Resolution: Junction box in aft fiddley was re-attatched.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 February 2026 Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. MI identified vsl's fixed fire pump connected with a alligator clips. 46 CFR 143.400(e)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2026
Resolved 5 March 2026
Resolution: Alligator clips from fixed fire pump was removed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 February 2026 Resolved
The owner, managing operator, or master of a towing vessel must ensure that the vessel's lifesaving and fire suppression and detection equipment is in good working order. MI witnessed the fwd standpipe from bow to fwd berthing not closed off. 46 CFR 140.650
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2026
Resolved 5 March 2026
Resolution: Vsl capped off fwd standpipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 30 December 2024 Resolved
The following systems must be equipped with gauges at the machinery location: (1) Main engine lubricating oil pressure and main engine RPM. RPM gauge for the main engine is inoperable. //46 CFR 143.230(c)(1)//
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2025
Resolved 19 March 2025
Resolution: New rpm gauge installed on MPE; all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 December 2024 Resolved
A towing vessel may not be operated without having onboard a valid COI issued by the Coast Guard as required by 46 CFR 136.202. Rectify prior to towing. 46 CFR 136.200(a)
Action required: 705 - Other - as specified
Due 12 December 2024
Resolved 30 December 2024
Resolution: Issued temporary COI.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 December 2024 Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. Fuel oil cut off valves did not operate properly to stop the flow of fuel to the engine and generator. 46 CFR 143.260(b)
Action required: 60 - Rectify deficiencies prior to movement
Due 12 December 2024
Resolved 30 December 2024
Resolution: MI observed proper function of fuel shut off valves to the engine and generator.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 December 2024 Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. The owner or managing operator must ensure that the system is arranged and installed so a fire in the engine room automatically sets off alarms on a fire detection control panel at the operating station. Vessel was not outfitted with a fire detection control panel at the operating station. 46 CFR 142.330(a)
Action required: 60 - Rectify deficiencies prior to movement
Due 12 December 2024
Resolved 30 December 2024
Resolution: Fire control panel installed by Hiller was operable from the operating station.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 12 December 2024 Resolved
Means must be provided for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. E/R ventilation openings could not be closed. Vessel had several holes from accommodation spaces into E/R. Prior to towing operations. 46 CFR 144.605
Action required: 705 - Other - as specified
Due 12 December 2024
Resolved 19 March 2025
Resolution: Owner installed mechanical closures in plenum deck ventilation openings. Holes from acommodation spaces to E/R were closed; all sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 December 2024 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Alarms must be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm; if the alarm at the operating station is a summary alarm, the specific alarm condition must be indicated at the machinery or bilge location. Operating station was not outfitted with a visible and audible alarm. Prior to towing operations. 46 CFR 143.230(b)
Action required: 705 - Other - as specified
Due 12 December 2024
Resolved 30 December 2024
Resolution: MI observed engine room alarms at the operating station.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 December 2024 Resolved
Machinery systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Fuel cutoff valves for port and starboard fuel tanks were leaking from packing. 46 CFR 143.205
Action required: 705 - Other - as specified
Due 12 December 2024
Resolved 30 December 2024
Resolution: MI observed proper function of fuel shut off valves to the engine and generator and no leaking from the packing.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 12 December 2024 Resolved
Each towing vessel operating north of lat. 32° N. or south of lat. 32° S. must carry at least one appropriate-size immersion suit, approved under approval series 160.171, for each person onboard. Two immersion suits carried onboard were not USCG type approved. Vessel limited to 03 persons onboard. Prior to issuance of COI. 46 CFR 141.350
Action required: 705 - Other - as specified
Due 12 December 2024
Resolved 30 December 2024
Resolution: Vessel has 05 CG approved immersion suits.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 December 2024 Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. The two watertight doors from engine room to the weather deck did not have gaskets. 46 CFR 140.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2025
Resolved 30 December 2024
Resolution: Engine room watertight doors have satisfactory gaskets.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 12 December 2024 Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. Machinery guards were missing on generator and on port and starboard sides of main diesel engine. 46 CFR 144.820
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2025
Resolved 30 December 2024
Resolution: Guards were installed on the generator and port and stbd sides of the main diesel engine.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 December 2024 Resolved
Decks and bulkheads designed to be watertight or weathertight must be maintained in that condition. There were several open bulkhead penetrations in aft engine room bulkhead, forward engine room bulkhead and fidley deck / bulkheads. 46 CFR 140.610(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2025
Resolved 30 December 2024
Resolution: Open bulkhead penetrations were filled.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 December 2024 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. High jacket water alarm for the main engine was unable to be tested. 46 CFR 143.230(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2025
Resolved 30 December 2024
Resolution: MI tested high jacket water alarm. Alarms setpoints were calibrated by third party. all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 December 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Dead end wires were present in the engine room. 46 CFR 143.205
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2025
Resolved 30 December 2024
Resolution: Dead end wires removed in engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 December 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Dead end wires were present in the lazarette. 46 CFR 143.205
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2025
Resolved 30 December 2024
Resolution: Dead end wires removed in lazarette.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 December 2024 Resolved
Alarms must be visible and audible at each operating station. Audible alarm for machinery room alarms was not operating reliably. 46 CFR 143.230(b)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2025
Resolved 30 December 2024
Resolution: Audible alarm were operating reliably.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 December 2024 Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea or 33 CFR part 84 as appropriate to its area of operation. Inboard screens on the sidelights were painted with gloss paint. 46 CFR 140.720
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2025
Resolved 30 December 2024
Resolution: Navigation lights screens were matte black.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 12 December 2024 Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 1 inch high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH —KEEP CLOSED”. Watertight door and hatch signs were not posted. 46 CFR 144.160(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2025
Resolved 30 December 2024
Resolution: MI observed watertight door and hatch signs were posted.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 12 December 2024 Resolved
Each escape hatch and emergency exit used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high: “EMERGENCY EXIT, KEEP CLEAR”. Emergency exit signs were not posted from the crew berthing area leading to the focsle. 46 CFR 144.160(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2025
Resolved 30 December 2024
Resolution: MI observed emergency exit signs were posted.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 December 2024 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The toggle switch for the alarm panel is currently located at the top of the engine room ladderwell, a position where it is vulnerable to accidental deactivation. 46 CFR 143.230(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2025
Resolved 30 December 2024
Resolution: Toggle switch for alarm panel was modified to prevent accidental deactivation.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 December 2024 Resolved
The following list of items must be recorded in the official logbook: Personnel records; Safety orientation; Record of drills and instruction; Examinations and tests; Operative navigational safety equipment; Navigation assessment; Navigation safety training; Oil residue discharges and disposals; Record of inspection of towing gear; and Fire-detection and fixed fireextinguishing. Vessel has been in a laid-up status and does not have a current logbook or logging system. 46 CFR 140.915(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2025
Resolved 19 March 2025
Resolution: Vessel's helm-connect profile was created and is now active. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 12 December 2024 Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. As per USCG Type Approval number 160.162/3/3, the life raft hydrostatic release is intended for disposal 2 years after installation. Life raft hydrostatic release was not marked with expiration date. 46 CFR 141.230
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2025
Resolved 30 December 2024
Resolution: Hydrostatic release was marked with the expiration date on the corresponding certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 December 2024 Resolved
Portable watertight containers for pyrotechnic distress signals must be of a bright color and must be clearly marked in legible contrasting letters at least 0.5 inches high with “DISTRESS SIGNALS.” Portable watertight container for pyrotechnic distress signals was not correctly marked. 46 CFR 141.375(e)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2025
Resolved 30 December 2024
Resolution: Container for distress signals was marked.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 July 2022 Resolved
All owners and operators of an existing towing vessel must have on board a valid COI prior to the specified phase-in period. This vessel has not scheduled and inspection or obtained a valid COI. The vessel shall be made available for Coast Guard COI inspection immediately and the vessel may no longer be permitted to operate.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 9 November 2035
Resolved 30 December 2024
Resolution: Issued Temp. COI.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 1 October 2018 Resolved
Vsl is broadcasting Invalid Call Sign
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 26 August 2022
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 18 October 2000 Resolved
NEEDS PROTECTIVE GUARD OVER MDE FLYWHEEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 November 2000
Resolved 26 October 2004
Lifesaving › Launching Appliances › Winch
Issued 18 October 2000 Resolved
HYDROLIC FLUID LEAKING ONTO EXPOSED WIRES.
Condition: Unknown
Due 18 November 2000
Resolved 26 October 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 18 October 2000 Resolved
POTABLE IVO OF BERTHING AREA NEEDS BRACKET.
Condition: Unknown
Due 18 November 2000
Resolved 26 October 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 October 2000 Resolved
ring life buoy needs a light.
Condition: Unknown
Due 12 November 2000
Resolved 26 October 2004
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 18 October 2000 Resolved
PFD MISSING VSL NAME, & LIGHTS AND WHISTLES.
Condition: Unknown
Due 18 November 2000
Resolved 26 October 2004
Personnel › Certificates/Documents/Licenses › License, Master
Issued 18 October 2000 Resolved
NEED MASTER ORIGINAL LIC, PHOTOCOPY WAS ON-BORAD.
Condition: Unknown
Due 18 November 2000
Resolved 26 October 2004

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.