MAURY USCG vessel records Sign in
← All vessels

GEOQUIP SAENTIS

GEOQUIP SAENTIS is a 2005 offshore supply vessel. The Coast Guard has recorded 13 inspections since 2006, most recently in March 2022, along with 11 deficiencies and 3 operational controls.

Records from 2006 to 2022. Most recent: inspection, 16 March 2022.

Built
2005
Last inspected
16 March 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9282132 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
814525
Flag
BAHAMAS, THE
—
Maury page id
psix-814525

Inspections, by type

…with no type recorded4
Years with a record 6 calendar years (2006–2022)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it1131 - Convention (Subpart B), Net Ton
3404 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

16 March 2022 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7430883
17 February 2022 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7397877
10 May 2021 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7193552
3 August 2020 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7043770
14 May 2020 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6953121
28 October 2019 Deficiency Check · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6843353
11 October 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6837249
9 October 2019 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6831315
18 May 2007 PII Safety Exam · Deficiency Check · ISPS II Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2933681
16 May 2006 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2650763
27 April 2006 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2635126
26 April 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2634033
19 April 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2628186

Deficiency record · 11

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 May 2021 Resolved
To prevent the ignition of flammable liquids, means shall be provided to control leaks of flammable liquids. PSCO observed oil leaks on drilling unit generator. 74SOLAS(04)II-2/4.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2021
Resolved 15 May 2021
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 10 May 2021 Resolved
The fire integrity of the divisions shall be maintained at openings and penetrations. PSCO observed cable penetrations above upper engine room door not sealed. 74SOLAS(04)II-2/9.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2021
Resolved 15 May 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 October 2019 Resolved
Any person who discharges or proposes to discharge pollutants, and who does not have an effective permit, must submit a completed application to the EPA. Vessel does not have a vessel general permit. 40 CFR 122.21(a) 40c
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 October 2019
Resolution: Vessel's master provided an electronic copy of the vessel general permit.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 October 2019 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of power. PSCO identified inoperable embarkation lighting at the port and starboard embarkation decks. 74 SOLAS (2014) III/11.4 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 October 2019
Resolved 28 October 2019
Resolution: Deficiency rectified. Electrician made appropriate repairs on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 October 2019 Resolved
Main and emergency switchboards shall be so arranged as to give easy access as may be needed to apparatus and equipment without danger to personnel. PSCO observed PFDs and immersion suits stored behind switchboards. 74 SOLAS (2004) II-1/45.2 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 October 2019
Resolved 28 October 2019
Resolution: Crew removed PFDs and immersion suits. Rectified on the spot.
Operations/Management › Pollution › Compliance with Transfer Procedures
Issued 18 May 2007 Resolved
Provide oil transfer procedures.
Action required: 705 - Other - as specified
Resolved 18 May 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 27 April 2006 Resolved
O-ring failure in CO2 system caused off-gassing of approximately 50% of available gas. Repair and have class attest to proper repair and function of CO2 system prior to departure from port. SOLAS CH II-2 Reg 10
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2006
Resolution: CLASS hired CO2 systems company to make repairs. repairs were made. recieved service report and class report attesting to repairs
Documentation › Markings/Placards › Oil Discharge Placard
Issued 27 April 2006 Resolved
Oil Placard needs to be posted IAW 33 CFR 155.450. 33CFR 155.450
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 16 May 2006
Resolution: Vessel now has placards in place IAW 33 Cfr 155.450. vessel also has extra palacard on board .
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 27 April 2006 Resolved
Vessel is missing Ballast Water Management Plan. Provide a vessel specific plan IAW 33 CFR 151.2035 to Coast Guard inspectors prior to departure from port. 33 CFR 151.2035
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2006
Resolution: Vessel now has a ship specfic ballast water mangement plan in place IAW 33 cfr 151.2035
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 27 April 2006 Resolved
Flag State Endorsement is missing for the three officers (3rd Engineer and two 2nd Officers). Provide valid flag state endorsements or proof of application for prior to deaprture from port. STCW Reg I/2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2019
Resolution: application has been sent for one of the 2nd officers. the ship has a new 3rd officer and a new 2nd officer. vessel is in compliance with Safe manning document and with STCW regulations
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 27 April 2006 Resolved
Viewing glass for incinerator needs to be replaced. SOLAS Ch I Reg 11
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 4 November 2006

Ownership record