MAURY USCG vessel records Sign in
← All vessels

TAI PROSPERITY

TAI PROSPERITY is a 2005 freight ship. The Coast Guard has recorded 32 inspections since 2006, most recently in May 2021, along with 12 deficiencies and 8 operational controls.

Records from 2006 to 2021. Most recent: inspection, 19 May 2021.

Built
2005
Last inspected
19 May 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9303510 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
814989
Flag
PANAMA
—
Maury page id
psix-814989

Inspections, by type

…with no type recorded13
Years with a record 13 calendar years (2006–2021)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it41372 - Convention (Subpart B), Gross Ton
26094 - Convention (Subpart B), Net Ton
77747 - Dead Weight, Metric Ton
88366 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

19 May 2021 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7200861
18 May 2021 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7195319
13 May 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7195912
14 May 2020 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6953427
17 March 2020 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6928018
22 February 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6920606
14 November 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6854933
21 September 2018 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6545738
29 March 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6373792
19 March 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6374797
7 March 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6096818
12 October 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6021213
30 October 2015 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5750708
16 October 2014 Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5005620
8 August 2014 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4948810
7 August 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4947294
7 August 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4947557
7 August 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4948155
6 August 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4946526
4 August 2014 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4937089
7 February 2010 PII Safety Exam · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3676638
28 March 2009 Deficiency Check · ISPS I Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3441515
28 March 2009 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3442834
24 March 2009 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3439029
7 June 2008 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3222001
25 March 2008 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3171122
2 May 2007 Random ISPS/MTSA/PSC · MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2920732
1 May 2007 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2920693
24 October 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2807452
4 May 2006 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2640466
3 May 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2640045
29 April 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2636863

Deficiency record · 12

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 May 2021 Resolved
Ship shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a class society which is recognized by the Administration. PSCO noted jacket water leaking from main engine. 74 SOLAS 14 11-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 May 2021
Resolved 19 May 2021
Resolution: Ship crew renewed O-rings to seal system from leaking. Pressurized system after repairs and observed no leaks.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 May 2021 Resolved
Ship shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a class society which is recognized by the Administration. PSCO noted excessive hydraulic oil accumulation on the steering gear. 74 SOLAS 14 II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2021
Resolution: Crew cleaned steering gear system and surrounding containment area. Witness operation of steering system with no leaks detected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 November 2019 Resolved
The machinery & associated piping system & fittings shall be of a design & construction for which they are intended. The limit switch on the fuel supply valve for #2 SSDG indicating open/closed is held on by baleing wire & does not operates intended.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 November 2019
Resolution: Sector NC received, reviewed and approved class report from Bureau Vertias to rectify outstanding discrepancy.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 14 November 2019 Resolved
The machinery & associated piping system & fittings shall be of a design & constructionfor which they are intended. The diesel pre ignition sensor on incenerator is held on by & is covered w/ electrical tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 November 2019
Resolution: Sector NC received, reviewed and approved class report from Bureau Vertias to rectify outstanding discrepancy.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 14 November 2019 Resolved
The machinery & associated piping system & fittings shall be of a design & construction adequate for the service for which they are intended. The fuel filter sensor on the #2 steering system is held on by electrical tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 November 2019
Resolution: Sector NC received, reviewed and approved class report from Bureau Vertias to rectify outstanding discrepancy.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 November 2019 Resolved
Electrical installations shall be such that the safety of the crew will be ensured. Workshop in E/R has overhead light installed in temporary manner. Light bulb does not have protective cover & cable is run to electrical outlet creating potential hazard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 November 2019
Resolution: Sector NC received, reviewed and approved class report from Bureau Vertias to rectify outstanding discrepancy.
Navigation › Collision/Grounding Avoidance › Radar
Issued 29 March 2018 Resolved
1530-RADAR-All ships 3,000 gross tonnage and upward shall, have a 3 ghz radar or, where considered appropriate by the administration, a second 9 ghz radar. PSCO observed that second radar display does not function. SOLAS 74 (a) 2014 Cons. V/19.2.7.1 17a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 March 2018
Resolved 21 September 2018
Resolution: Recieved Class, Tech., and Flag report attesting to repair - new SOLAS Safety Solas Equipment Certificate issued.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 8 August 2014 Resolved
The vessel experienced propulsion loss while in the Mississippi River.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2014
Resolved 9 August 2014
Resolution: Received, reviewed and accepted class report from BV stating that repairs were completed and found satisfactory.
Operations/Management › Pollution › Control of Garbage
Issued 4 August 2014 Resolved
0190 - Ship's logbooks - The entry for each discharge or incineration shall include date and time, position, of the ship, category of the garbage and the estimated amount discharged or incinerated. Entries made into the garbage record book by the [name withheld] on 5May13, 10Nov13, and 17Jun14 were not filled out in accordance with posted instructions. Specifically the PSCO observed the following, a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 October 2014
Resolution: Received a Panama Flag report satisfying the requirement.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 4 August 2014 Resolved
0715 - detection - the function of the fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction of the Administration by means of equipment producing hot air at the appropriate temperature. The crew is testing the fixed heat detectors with a lighter. The Chief Engineer stated that he does not have the proper mechanism to test the heat detectors. Provide
Action required: 705 - Other - as specified
Due 4 September 2014
Resolved 16 October 2014
Resolution: Received a Panama Flag report satisfying the requirement.
Lifesaving › Launching Appliances › Davit
Issued 7 June 2008 Resolved
Limit switch for the stbd motor lifeboat is sticking/malfunctioning, preventing smooth/proper recovery of MLB. Repair/ replace limit switch to sat of class. SOLAS (2004 Ed) III /20.2
Action required: 15 - Rectify deficiencies by next port
Resolved 28 March 2009
Resolution: Recieved class report attesting to proper repair of limit switch.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 7 June 2008 Resolved
Crew unfamiliar with abandon ship drill (lowering of lifeboat). SOLAS (2004 Ed) III/19.3.3
Action required: 705 - Other - as specified
Due 7 June 2008
Resolved 7 June 2008
Resolution: Reviewed with crew, required crew to demonstrate lowering lifeboat numerous times satisfactorily.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.