MV CHLOE CANDIES is a 2006 industrial vessel. The Coast Guard has recorded 19 inspections since 2016, most recently in October 2025, along with 8 deficiencies and 2 casualty investigations between 2019 and 2023.
Records from 2016 to 2025. Most recent: inspection, 9 October 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
DocumentationValid · issued 2 June 2026 · expires 31 July 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4057 - Convention (Subpart B), Gross Ton 1217 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
19 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; 2 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 19
9 October 2025ACP COI Oversight · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8233247
3 February 2025MTSA/ISPS Verification · ACP COI Oversight · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8064829
31 October 2024Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8046824
28 June 2024Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7986669
18 April 2024Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7897422
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 3 February 2025Resolved
VSL ENGAGED IN COMMERCIAL SERVICE THAT DOES NOT CARRY PASSENGERS SHALL MAINTAIN A VIDEO SURVEILLANCE SYSTEM.
MV CHLOE CANDIES DID NOT HAVE AN INSTALLED VIDEO SURVEILLANCE SYSTEM. VESSEL CONTAINED DETAILED PLANS AND ALL EQUIPMENT READY FOR INSTALL, BUT CANNOT AT THIS TIME DUE TO BEING UNDER CONTRACT AND SHALL INSTALL WITHIN 30 DAYS OF INSPECTION DATE. CONTACT MARINE INSPECTOR FOR CONSIDERATIONS.
CITE: 46 USC 4901
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2025
Resolved 20 March 2025
Resolution: Vessel properly installed the cameras needed to fulfill SASH requirements.
Watertight doors and hatches in machinery spaces were found not to be watertight. Vessel shall install satisfactory gaskets and make door adjustments to ensure that watertight integrity is maintained in the following spaces: adjust watertight door in the transducer space, adjust watertight door leading from the engine room to ECR, adjust and replace gasket on the watertight door from the engine room to the deck, and adjust z-drive emergency escape hatch. Replace worn gaskets on all three hatch covers located on the focsle. Clean, replace, and or rebuild both bow thruster emergency escape hatch covers. Hatch covers are severely corroded in several areas that impact watertight integrity.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 June 2022
Resolution: MI visually inspected all watertight doors and gaskets to the satisfaction of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 March 2020Resolved
02 life jackets were found un-servicable. Replace both life jackets at the engineering watch station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2020
Resolution: Cleared by Lloyds Register.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 March 2020Resolved
Emergency lighting in the vicinity of the emergency switchboard was insufficient; replace battery in the emergency light.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2020
Resolution: Cleared by Lloyds Register.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 4 March 2020Resolved
Front of emergency switchboard allowed for access inside via two small size holes posing a potential hazard to personnel; close off front of switchboard to eliminate potential safety hazard to personnel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2020
Resolution: Cleared by Lloyds Register
The procedure for tests must be in a sequential-checkoff format and set forth the details of the test. In Class report/PSTP cards, multiple tests were identified as missing information, not aligning with details set forth in PSTP approval letter, having been conducted by a
third party w/ no supporting documentation, or having
not been conducted at all/at proper intervals.Provide proper documentation showing proper completion of all PSTP.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 February 2021
Resolution: MI observed completed PSTPs from 2020.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 March 2020Resolved
Fire boundary doors shall be self-closing. Make necessary door adjustments to ensure Class A fire boundaries are maintained for the galley door, main deck ladder well door, and the door leading from the ladder well to the bridge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2020
Resolution: Cleared by Lloyds Register
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 4 March 2020Resolved
Dampers were corroded in multiple areas affecting closure and weather tightness. Make proper repairs to 02 ventilation dampers located in the forward starboard focsle.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 March 2020
Resolution: Cleared by Lloyds Register
24 April 2019Routine · role: Involved in a Marine Casualty · activity 6671005
21 May 2023Routine · role: Involved in a Marine Casualty · activity 7740971
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.