Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)43.2 ft × 13.0 ft × 5.4 ft
Registered tonnagegross 18 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSCHWARZ MARINE COMPANY · TWO RIVERS · built 1962
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMILWAUKEE, WI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 September 2025 · expires 30 September 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Regulatory (Subpart C or D), Gross Ton 11 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 10
9 December 2025Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8279859
3 November 2025COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8262362
4 June 2025Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8149702
10 September 2024Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8000311
16 August 2023Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7770142
19 July 2022Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7572449
6 October 2021Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7324089
4 March 2021Deficiency Check
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7118133
16 June 2020COI Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6978574
8 September 2011Industry Initiated Exam
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4139138
The following alarms must be provided for auxiliary generators. Engine high cooling and low lubricating pressure. Present testing results for the same, logged.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 9 December 2025
Resolution: Alarm testing for genset was presented.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 November 2025Resolved
Extension cords must not be used as a permanent connection to a source of electrical power. Remove permanent green extension cord in pilot house.
Action required: 10 - Deficiency Rectified
Resolved 18 November 2025
Resolution: Extension cord was removed in front of Inspectors.
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and stern of vessel. Port and starboard bow name needs contrasting paint color from the hull.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 9 December 2025
Resolution: Vessel name on bow sides has been painted contrasting color from hull.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 September 2024Resolved
Electrical systems must be maintained to ensure proper operation. The stbd outboard battery box is missing its cover. Procure a new battery box cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2024
Resolved 12 September 2024
Resolution: Operator sent photo showing the battery box cover has been replaced.
Action required: 705 - Other - as specified
Due 6 October 2021
Resolved 6 October 2021
08 - Alarms › N/A - No Subsystem › General alarm
Issued 14 July 2020Resolved
Each towing vessel must be fitted with a general alarm and P/A system i.a.w. 143.235(b). Vessel does not have a P/A or general alarm.
Action required: 705 - Other - as specified
Due 1 April 2021
Resolved 4 March 2021
Resolution: ?Verified and tested installed PA system
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 July 2020Resolved
Each towing vessel operating on oceans, coastwise, or Great Lakes routes must have a means to take blood pressure readings, splint broken bones, and apply large bandages for serious wounds i..a.w. 140.435.
Vessel does not have a device to monitor blood pressure.
Action required: 705 - Other - as specified
Due 30 April 2021
Resolved 4 March 2021
Resolution: BP monitor and splint bag onboard
143.230(a) Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention.
Low hydraulic steering fluid level Alarm must:Be visible and audible at each operating station
Action required: 705 - Other - as specified
Due 30 April 2021
Resolved 7 March 2021
Resolution: verified audible and visual alarms
Each towing vessel must perform the applicable tests in Table 143.245(b) and must be recorded in accordance with part 140:
Alarm set points: Twice every 5 years, with no more than 3 years elapsing since last test.
Action required: 705 - Other - as specified
Due 30 April 2021
Resolved 4 March 2021
Resolution: Verified testing completed
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 July 2020Resolved
Each detector, control panel, remote indicator panel, and fire alarm are approved by the Commandant under approval series 161.002 or listed by a NRTL as set forth in 29 CFR 1910.7; and must be installed, tested, and maintained in accordance with the manufacturer's design manual. Fire detection system manual not available for test instruction.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2021
Resolved 4 March 2021
Resolution: Fire detection system instructions onboard and verified testing performed by vendor.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.