MAURY USCG vessel records Sign in
← All vessels

TRADEPOORT

TRADEPOORT is a 1998 freight ship. The Coast Guard has recorded 56 inspections since 2000, most recently in January 2007, along with 24 deficiencies and 15 operational controls.

Records from 2000 to 2007. Most recent: inspection, 30 January 2007.

Built
1998
Last inspected
30 January 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9184689 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
NETHERLANDS
—
Maury page id
psix-8154

Inspections, by type

…with no type recorded40
Years with a record 8 calendar years (2000–2007)
The 56 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3282 - Dead Weight, Gross Ton
2615 - Convention (Subpart B), Gross Ton
4944 - Displacement, Gross Ton
1226 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 56

30 January 2007 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2864039
4 January 2007 Ballast Water Examination · MARPOL Annex I Examination · NPV Safety Exam · MARPOL Annex V Examination · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2850351
4 January 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2850432
30 August 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2764441
2 August 2006 ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2733863
19 July 2006 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2718151
16 July 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2714392
4 July 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2700574
13 June 2006 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2678842
24 May 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2657596
24 May 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2658116
3 March 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2595464
3 February 2006 Random ISPS/MTSA/PSC · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2578885
6 January 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2563697
6 January 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2563724
5 January 2006 ISPS II Exam · Ballast Water Examination · NPV Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2561081
9 November 2005 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2535015
1 July 2005 PII Safety Exam · MARPOL Annex V Examination · ISPS III Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2405567
5 April 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2352893
22 March 2005 MARPOL Annex I Examination · Random ISPS/MTSA/PSC · PII Safety Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2315775
5 January 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2269112
5 January 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2269468
5 October 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2213864
18 September 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2199252
6 August 2004 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2158221
3 August 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2154918
2 August 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2153656
8 July 2004 ISPS II Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2126439
7 July 2004 ISPS II Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2124881
25 June 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2110691
11 June 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2095569
27 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2054913
27 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2054935
16 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2045880
9 January 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1980982
9 December 2003 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1960998
17 October 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1930684
14 October 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1928183
5 August 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1867447
2 May 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1784909
2 May 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1784945
11 December 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1717783
27 November 2002 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1711646
31 October 2002 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1699336
29 October 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1697787
15 October 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1689104
19 September 2002 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1677814
23 August 2002 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1666415
27 June 2002 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1640273
30 April 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1611112
29 April 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1610866
1 September 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 164343
24 May 2001 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 290337
18 August 2000 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 281219
22 July 2000 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 109061
8 June 2000 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 278586

Deficiency record · 24

Communications › Alarms/Indicators › Propeller Pitch Position Indicator
Issued 24 May 2006 Resolved
Vessel's propellor pitch indicator located on the bridge is not operational.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 June 2006
Resolution: Received Technician’s report on repairs to pitch indicators
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 5 January 2006 Resolved
Echo depth sounding device inoperative: Provide technician survey report prior to departure, attesting to satisfactory repair or stating reason(s) for inability to repair prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 January 2006
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 22 March 2005 Resolved
OILY WATER SEPARATING SYSTEM INOPERATIVE
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2005
Resolved 23 March 2005
Resolution: Received Class Report (Bureau Veritas job MIA0/2005/UNK; BV ID 00296Y): OWS repaired and test satisfactorily.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 22 March 2005 Resolved
MARINE SANITATION DEVICE INOPERATIVE. MODIFICATIONS MADE TO USCG-APPROVED TYPE-II.
Action required: 705 - Other - as specified
Due 22 March 2005
Resolved 5 April 2005
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 22 March 2005 Resolved
NO DESIGNATED HOSPITAL SPACE. CITE: ILO 147
Action required: 705 - Other - as specified
Due 5 April 2005
Resolved 23 March 2005
Resolution: Received Class Report (Bureau Veritas job MIA0/2005/UNK; BV ID 00296Y): Crewmember removed from hospital space.
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 22 March 2005 Resolved
NO PRE-ARRIVAL CHECKS COMPLETED FOR ARRIVAL TO JACKSONVILLE, FL.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 March 2005
Resolved 23 March 2005
Resolution: JACMS Inspector verified presence of previous log entries for pre-arrival checks. Master stated conducting and logging checks is part of pre-arrival procedure for vessel.
Fire Fighting › Fire Pumps › Arrangement
Issued 22 March 2005 Resolved
BALLAST PUMP STARBOARD SIDE INOPERATIVE. IMPROPER ARRANGEMENTS OF PUMPS.
Action required: 705 - Other - as specified
Due 22 March 2005
Resolved 23 March 2005
Resolution: Received Class Report (Bureau Veritas job MIA0/2005/UNK; BV ID 00296Y): Vessel has adequate arrangement of pumps per SOLAS 74 (Amend) II-2/52.
Fire Fighting › Remote Fuel Shutoff › General
Issued 22 March 2005 Resolved
FUEL-OIL TRIP FOR EMERGENCY DIESEL GENERATOR INOPERATIVE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2005
Resolved 23 March 2005
Resolution: Received Class Report (Bureau Veritas job MIA0/2005/UNK; BV ID 00296Y): Fuel-Oil Trip repaired.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 March 2005 Resolved
NO MACHINERY GUARD ON EMERGENCY FIRE PUMP: EXPOSED COUPLER.
Action required: 705 - Other - as specified
Due 22 March 2005
Resolved 5 April 2005
Resolution: Per BV Class Report of 04 Apr 2005 (BV Job MIA0/2005/J0268), guard fitted to emergency fire coupling.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 22 March 2005 Resolved
WIRE RUN FROM ENGINE ROOM TO SWITCHBOARD ROOM MISSING FIRE STOP AT A-0 BULKHEAD.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 March 2005
Resolved 23 March 2005
Resolution: Received Class Report (Bureau Veritas job MIA0/2005/UNK; BV ID 00296Y): Bulkhead penetration sealed with proper material.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 March 2005 Resolved
VARIOUS DEAD-END WIRES STARBOARD SIDE ENGINE ROOM FORWARD.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2005
Resolved 5 April 2005
Resolution: Per BV Class Report of 04 Apr 2005 (BV Job MIA0/2005/J0268), dead end wires removed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 March 2005 Resolved
TEMPORARY REPAIR ON STARBOARD SIDE SALT-WATER COOLING PUMP SUCTION LINE FOR SHIP'S SERVICE DIESEL GENERATOR.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2005
Resolved 5 April 2005
Resolution: Per BV Class Report of 04 Apr 2005 (BV Job MIA0/2005/J0268), pipe on discharge from SW cooling pump repaired.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 22 March 2005 Resolved
NON-CONFORMITIES AND THIER POSSIBLE CAUSES ARE NOT REPORTED: OILY WATER SEPERATOR, BILGE PUMP, SEWAGE SYSTEM. Cite: ISM10.2.2
Action required: 705 - Other - as specified
Due 22 March 2005
Resolved 22 March 2005
Resolution: JACMS received Det Norske Veritas Class Report for ISM Audit (dated 2005-03-22 for DNV Co. ID 118145, Ship 25946). Surveyor required internal audit of SMS on 4/22/2005.
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 22 March 2005 Resolved
CHIEF ENGINEER DOES NOT DEMONSTRATE PROPER FAMILIARIZATION ON HIS DUTIES. Cite: ISM6.3
Action required: 705 - Other - as specified
Due 22 March 2005
Resolved 22 March 2005
Resolution: JACMS received Det Norske Veritas Class Report for ISM Audit (dated 2005-03-22 for DNV Co. ID 118145, Ship 25946). Surveyor required internal audit of SMS on 4/22/2005.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 22 March 2005 Resolved
NON-CONFORMITY REPORTS NOT FILED IN ACCORDANCE WITH VESSEL'S SMS FOR INOPERATIVE MACHINERY IN ENGINE ROOM. Cite: ISM11
Action required: 705 - Other - as specified
Due 22 March 2005
Resolved 22 March 2005
Resolution: JACMS received Det Norske Veritas Class Report for ISM Audit (dated 2005-03-22 for DNV Co. ID 118145, Ship 25946). Surveyor required internal audit of SMS on 4/22/2005.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 22 March 2005 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 22 March 2005
Resolved 24 March 2005
Resolution: JACMS received Det Norske Veritas Class Report for ISM Audit (dated 2005-03-22 for DNV Co. ID 118145, Ship 25946). Surveyor required internal audit of SMS on 4/22/2005. Chief Engineer relieved of duty on 3/24/2005.
Fire Fighting › Fire Hoses
Issued 23 August 2002 Resolved
Fire hoses (5) have leaks IAW SOLAS 74 Amended/ II-2/ 21. Provide with replacement fire hoses (5) prior to departure. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2002
Resolution: Three new fire hoses provided onboard and two remaining hoses cut to remove holed area.
Lifesaving › Rescue Boat
Issued 23 August 2002 Resolved
Rescue boat not launched within last 3 months IAW SOLAS 74 Amended/ III/ 18.3.7 Conduct boat drill to the satisfaction of attending USCG inspector prior to departure from next U.S. port.
Action required: 15 - Rectify deficiencies by next port
Resolved 18 September 2002
Resolution: rescue boat launched on 08SEP02. Drill conducted to the satisfaction of the attending inspector.
Engineering › Steering Gear System
Issued 23 August 2002 Resolved
Steering instructions and block diagram in steering room and bridge inadequate IAW SOLAS 74 Amended/ V/ 19-2(c)(i) Correct NLT 23SEP02.
Due 23 September 2002
Resolved 19 September 2002
Resolution: Steering instructions and block diagrams located on the bridge and the steering gear room found to be in compliance with SOLAS/V/19-2(c)(i)
Lifesaving › Launching Appliances
Issued 23 August 2002 Resolved
Launching instructions for rescue boat are not specific to type of rescue boat on board vessel IAW SOLAS 74 Amended/ III/ 9.2.1 Provide appropriate launching instructions. LEGACY COMPONENT DESC: Launching Instructions
Due 6 September 2002
Resolved 19 September 2002
Resolution: Posted launching instructions are appropriate to the rescue boat on board.
Fire Fighting › Structural - A Class Divisions
Issued 23 August 2002 Resolved
Fire door located at emergency escape trunk (lowest deck in engine room) has no door handle IAW SOLAS 74 Amended/ II-2/ 47.1 LEGACY COMPONENT DESC: Openings - Fire Doors
Due 6 September 2002
Resolved 19 September 2002
Resolution: Missing handle on the door has been replaced and is in operable condition.
Fire Fighting › Fixed Fire Detection System
Issued 23 August 2002 Resolved
Smoke detector in work shop is inoperable IAW SOLAS 74 Amended/ II-2/ 52.1 LEGACY COMPONENT DESC: Smoke Detectors
Due 23 September 2002
Resolved 3 September 2002
Resolution: Smoke detector replaced on 3 SEP 02 with operable detector in compliance with SOLAS 74 Amended/II-2/ 52.1
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 27 June 2002 Resolved
Letter of Deviation granted for vessel to enter the Port of Savannah with an inoperable gyro compass repeater at the main steering stand. Repair gyro compass and submit technicians report prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2002
Resolved 28 June 2002
Resolution: Received technicians report from [name withheld] stating gyro compass was repaired and tested to the satisfaction of the attending technician.
Engineering
Issued 8 June 2000 Resolved
NO BUNKERING TRANSFER PROCEDURES ON BOARD, CORRECT PRIOR TO NEXT U.S. BUNKERING.
Condition: Unknown
Due 18 August 2000
Resolved 18 August 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.