MAURY USCG vessel records
← All vessels

ALWAYS SUNDAY

ALWAYS SUNDAY is a 2006 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2016, most recently in April 2026, along with 37 deficiencies, 2 operational controls and 1 casualty investigation in 2025.

Records from 2016 to 2026. Most recent: inspection, 22 April 2026.

Built
2006
Last inspected
22 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 April 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDQ8070
815595
Flag
UNITED STATES
Maury page id
psix-815595

Documentation record

Registered dimensions (L × B × D)41.5 ft × 23.0 ft × 8.5 ft
Registered tonnagegross 28 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMAINE CAT · BREMEN, ME, UNITED STATES · built 2006
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portPANAMA CITY BEACH, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 4 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Simplified, Gross Ton
22 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 24

22 April 2026 Internal Structural Exam · Administrative Inspection · Vessel Attendance · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8353954
23 February 2026 Deficiency Check · Special · Vessel Attendance · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8314532
29 September 2025 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8243451
26 August 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8218398
20 March 2025 Damage Survey · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8097268
20 March 2025 Type not recorded
No type recorded · Station Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8097374
20 March 2025 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8098517
10 September 2024 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8000037
18 July 2024 Drydock Exam · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7961194
11 October 2023 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7807036
5 September 2023 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7785508
16 February 2023 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7637028
26 August 2022 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7546184
9 August 2021 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7283357
9 June 2021 Internal Structural Exam · COI Inspection · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7220827
9 October 2020 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7074532
21 August 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6770407
16 July 2019 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6752604
22 April 2019 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6651385
23 July 2018 Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6487905
9 August 2017 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6235423
2 May 2017 Deficiency Check · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6136926
19 July 2016 Administrative Inspection · COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5944615
12 February 2016 Damage Survey · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5814608

Deficiency record · 37

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 March 2026 Resolved
All small battery installations must have covers or other means to protect against falling objects.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2026
Resolved 12 March 2026
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 March 2026 Resolved
High water alarm is required in all compartments with a through hull fitting.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2026
Resolved 6 March 2026
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2026 Resolved
Stowage conatiners for required life jackets must be properly labeled.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2026
Resolved 12 March 2026
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 26 August 2025 Resolved
A pre-engineered fixed gas fire extinguishing system must have a means to shut down all ventilation systems and all engines that draw intake air from within the protected space. Vessel is not equipped with means to shut down ventilation. 46 CFR 181.420(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 29 September 2025
Resolution: Installation of four ventilation covers completed. See documents for picture.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 20 March 2025 Resolved
Each vessel inspected and certificated under the provisions of this subchapter must, when any passengers are aboard during the tenure of the certificate, be in full compliance with the terms of the certificate. The vessel was involved in a marine casualty on 20MAR25 whereby its propulsion equipment and/or structural integrity may have been compromised. The vessel shall not carry passengers until a damage assessment and any required repairs are complete to the satisfaction of an attending Marine Inspector. Once the vessel is safely docked, permission from the OCMI must be granted prior to the vessel moving. 46 CFR 176.100(b) - 701 - C
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2025
Resolved 22 March 2025
Resolution: MI attended to conduct full underway steering test after inspecting refurbished prop and rudder.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 August 2024 Resolved
All vessels must have navigation lights that are in compliance with applicable sections on international and inland navigation rules. Vessels under power stern light is out. Repair to the satisfaction of the attending MI. Vessel is restricted from power operations after sunset until repaired. 46 CFR 183.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2024
Resolved 10 September 2024
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 August 2024 Resolved
Gauges to indicate engine revolutions per min., jacket water discharge temp and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. Vessels engine gauges at the operating station do not show J/W temp or L/O pressure. Repair to the satisfaction of the attending MI. 46 CFR 182.410 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2024
Resolved 16 October 2024
Resolution: New gauges installed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 16 August 2024 Resolved
On a vessel of at least 26 feet a visual and audible alarm must be provided at the operating station to indicate high water level. Vessel's high water alarms have a visual and very low audible alarm. Audible alarm requires to be loud enough that the operators attention would be drawn when sounded. Repair to the satisfaction of the attending MI. 46 CFR 182.530
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2024
Resolved 10 September 2024
Resolution: New audible alarm installed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 August 2022 Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: Three hand red flare distress signals and three hand orange smoke distress signals. Replace expired flares.
Action required: 10 - Deficiency Rectified
Due 26 August 2022
Resolved 26 August 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 August 2022 Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. Replace expired alcohol swabs.
Action required: 10 - Deficiency Rectified
Due 26 August 2022
Resolved 26 August 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Remove water from battery compartment.
Action required: 10 - Deficiency Rectified
Due 26 August 2022
Resolved 26 August 2022
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 26 August 2022 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. Renew expired COD.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2022
Resolved 6 September 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 October 2019 Resolved
Conduct operational test on fixed fire extinguishing system (FIREBOY) following installation of replacement cylinders in Port and STBD engine rooms. Test shall be conduct in the presence of attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2019
Resolved 26 November 2019
Resolution: Vessel rep provided video of both systems operational.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 August 2019 Resolved
Repair/replace visual light indicator for pre-engineered fixed gas fire extinguishing system. Complete by August 28th, 2019.
Action required: 705 - Other - as specified
Due 28 August 2019
Resolved 17 October 2019
Resolution: Indicators replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 August 2019 Resolved
Provide manufacture date for both Port and STBD fireboy cylinders.
Action required: 705 - Other - as specified
Due 28 August 2019
Resolved 17 October 2019
Resolution: New cylinders ordered.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 22 April 2019 Resolved
Make opening/penetration in STBD aft Engine Room vapor/watertight. *Prior to credit Drydock
Action required: 705 - Other - as specified
Resolved 26 April 2019
Resolution: Opening closed with starboard.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 22 April 2019 Resolved
Grind down fiber glass on areas identified by attending Marine Inspectors and repair: 02 spots on outside port hull, 01 area on aft hull tunnel. Repair 1st layer of de-laminated glass with same layup schedule (chop mat) and epoxy resin. Make area available for re-inspection once repair has been completed. *Prior to credit Drydock
Action required: 705 - Other - as specified
Resolved 23 April 2019
Resolution: FRP repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 April 2019 Resolved
Replace prop hubs on both folding props *Prior to credit Drydock
Action required: 705 - Other - as specified
Resolved 26 April 2019
Resolution: Prop hubs replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 22 April 2019 Resolved
Provide a metallic positive shutoff valve at the hull penetration for each installed submersible bilge pump (04). *Prior to credit Drydock
Action required: 705 - Other - as specified
Resolved 26 April 2019
Resolution: Shutoff valves installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2019 Resolved
Clean all corrosion from battery terminals and replace wing nuts with permanent type connections.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 May 2019
Resolution: Battery terminals cleaned.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 April 2019 Resolved
Repair/replace forward deck hatch on Portside, hatch missing securing device and hinge was broken off.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2019
Resolution: New hardware installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 July 2018 Resolved
Provide/demonstrate means to restart STBD engine after pre-engineered fixed fire extinguishing system is activated.
Action required: 705 - Other - as specified
Due 30 July 2018
Resolved 30 July 2018
Resolution: Engine is able to restart in override mode after simulating Fireboy discharge.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 July 2018 Resolved
Inspect/service B-II portable fire extinguisher. Last serviced April 2017.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2018
Resolution: B-II fire extinguisher serviced and on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 July 2018 Resolved
Electrically bong both Port/STBD fuel tanks to a common ground.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2018
Resolution: Tanks bonded to common ground.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 July 2018 Resolved
Join metallic fill pipes to Port/STBD fuel tanks to protect against generation of static discharge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2018
Resolution: File pipes joined to tank with bonding wires.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 23 July 2018 Resolved
Magnetic compass must be illuminated during limited visibility (night).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2018
Resolution: Light operational.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 August 2017 Resolved
Provide complete first aid kit. Ammonia inhalants are expired.
Action required: 705 - Other - as specified
Due 17 August 2017
Resolved 24 August 2017
Resolution: Provided complete first aid kit with ammonia inhalants.
Documentation › Certificates/Documents › Stability Letter
Issued 10 August 2017 Resolved
Provide Sail Plan with stamped approval date Jan 6, 2011 in accordance with Stability Letter.
Action required: 705 - Other - as specified
Due 17 August 2017
Resolved 16 January 2018
Resolution: Obtained sail plan.
Communications › Radio Communications › VHF Radiotelephone
Issued 10 August 2017 Resolved
Provide VHF-DSC radio with programmed MMSI and GPS input
Action required: 705 - Other - as specified
Due 10 September 2017
Resolved 24 August 2017
Resolution: Vessel connected GPS to radio and programmed MMSI.
Communications › Alarms/Indicators › High Water Alarm
Issued 10 August 2017 Resolved
Provide visual indicator for starboard aft high water alarm
Action required: 705 - Other - as specified
Due 17 August 2017
Resolved 24 August 2017
Resolution: Repaired indicator for high water alarm.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 10 August 2017 Resolved
Provide independent Fire Boy shutdowns and overrides for both engines.
Action required: 705 - Other - as specified
Due 17 August 2017
Resolved 24 August 2017
Resolution: Installed seperated controller and indicators for port engine.
Sail Rigging › Spars › Masthead Hardware and Sheaves
Issued 2 May 2017 Resolved
Unstep mast and make available for inspection.
Action required: 705 - Other - as specified
Resolved 5 May 2017
Resolution: Mast unstepped.
Engineering › Fuel Oil Service System › Valve
Issued 2 May 2017 Resolved
Renew/repair fuel oil sensor housing in port engine room.
Action required: 705 - Other - as specified
Resolved 5 May 2017
Resolution: Fuel oil sensor housing serviced.
Sail Rigging › Catamaran › Crossbeam
Issued 2 May 2017 Resolved
Provide repair proposal for forward crossbeam prior to conducting repairs.
Action required: 705 - Other - as specified
Resolved 5 May 2017
Resolution: Crossbeam repaired by welder.
Engineering › Fuel Oil Service System › Hose
Issued 19 July 2016 Resolved
Replace fittings on fuel cutout valves to the satisfaction on attending marine inspector
Action required: 705 - Other - as specified
Due 19 August 2016
Resolved 15 August 2016
Resolution: Renewed valves, hoses, and fittings
Engineering › Fuel Oil Service System › Hose
Issued 19 July 2016 Resolved
Renew fittings to flow scan in stbd engine room with manufacturer approved fittings
Action required: 705 - Other - as specified
Due 19 August 2016
Resolved 15 August 2016
Resolution: Renewed hoses and fittings.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 12 February 2016 Resolved
Make permanent repairs to port outdrive skirt and port engine mounts to the satisfaction of an attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2016
Resolved 18 February 2016

Casualty record · 1

20 March 2025Routine · role: Involved in a Marine Casualty · activity 8098517
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.