A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
2 December 2024
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8042011
19 July 2023
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7735901
8 July 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7498693
20 April 2022
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7413702
29 April 2021
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7183981
23 June 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6986469
27 April 2020
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6951420
9 July 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6742193
14 June 2018
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6444826
23 April 2018
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6398357
27 June 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6188989
29 April 2016
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5867078
29 April 2016
Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5867245
3 June 2014
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4878312
6 May 2014
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4851792
19 June 2012
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4347603
9 December 2011
Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4205157
24 April 2008
Annual Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3194766
4 June 2007
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2951059
25 May 2006
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2658430
24 April 2006
Initial Certification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2632462
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 July 2022
Resolved
Spaces containing propulsion machinery are required to have fixed fire system protection. The fireboy bottle did not have a charge indicated on the pressure gauge. Replace bottle to satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2022
Resolved 25 August 2022
Resolution: Verified re-install of pre-engineered firboy bottle, in the green, all sat. Tested engine shutdown and restart.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2020
Resolved
Each ring life buoy must meet the requirements of found in 46CFR160.050. The vessel does not have a ring buoy onboard that meets these requirements.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 8 July 2020
Resolution: Confirmed that correct ring buoy was installed.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 23 June 2020
Resolved
The stability letter must be kept onboard in a weathertight container and readily available. The vessel does not have their stability letter onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 8 July 2020
Resolution: Verified that stability letter was onboard.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 23 June 2020
Resolved
The COI must be kept onboard in a weathertight container and readily available. The vessel does not have their COI onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 8 July 2020
Resolution: Confirmed that the COI was onboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 July 2019
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted
in the vicinity of the vent.
Vessel operator could not readily operate close/open of the vents.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2019
Resolved 22 July 2019
Resolution: Vessel operator provided photographs of new vents with closures installed on engine cover.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 July 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts and nautical publications.
Vessel operator has a 2004 Inland Navigation Rules.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2019
Resolved 22 July 2019
Resolution: Vessel operator provied photograph on updated 2018 Inland Navigation Rules book.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 27 June 2017
Resolved
Vsl rep had copies of operators' licenses. Issued requirement to see original licenses
Action required: 705 - Other - as specified
Due 11 July 2017
Resolved 10 July 2017
Resolution: Rcvd copies of licenses
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 27 June 2017
Resolved
Cooling line did not have double hose clamps on it.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2017
Resolution: Verified double hose clamps
Lifesaving › Lifebuoys › Serviceable
Issued 11 May 2016
Resolved
Life ring bouy no longer serviceable. Provide life ring bouy prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 May 2016
Resolution: New life ring bouy provided.
Fire Fighting › Fire Bucket › Availability
Issued 11 May 2016
Resolved
Fire buckets missing. Provide fire buckets prior to carrying passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 12 May 2016
Resolution: New 2.5 gal fire buckets provided.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (air intake)
Issued 11 May 2016
Resolved
Air intake piping not properly secured. Repair/replace and ensure proper way of securing intake ventillation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 20 May 2016
Resolution: Ventillation was reinstalled with screws.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 May 2016
Resolved
Provide first aid kit.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 12 May 2016
Resolution: New first aid kit provided.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 June 2012
Resolved
60 Ft Lifeline on ring buoy is wasted due to sunlight.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 2 July 2012
Resolved 27 June 2012
Resolution: New 60 ft lifeline placed on vessel.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 18 June 2012
Resolved
Lifebuoy missing retro tape.
Condition: Improper/Lack of Maintenance
Due 2 July 2012
Resolved 27 June 2012
Resolution: Retro tape placed on life ring.
Documentation › Certificates/Documents › Stability Letter
Issued 9 December 2011
Resolved
CG 835 FOR NON-COMPLIANCE WITH AAWP STANDARDS, MAX. PERSONS ALLOWED ONBOARD REDUCED TO 18
Due 1 June 2012
Resolved 13 December 2011
Resolution: At owner''s request, conducted voluntary weight ratio reduction, issued new stability letter and amended COI.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 24 April 2006
Resolved
Provide a logbook, charts, nav rules and appropriate navigation pubs for the operating area.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2006
Resolved 26 May 2006
Resolution: Provided sat.
Documentation › Markings/Placards › Certificate of Number (state)
Issued 24 April 2006
Resolved
Properly place the state registration number on the bow.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2006
Resolved 26 May 2006
Resolution: Registration numbers placed on hull sat.
Documentation › Logs/Records › Drug Test Records
Issued 24 April 2006
Resolved
Prove enrollment in an approved drug and alcohol program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2006
Resolved 26 May 2006
Resolution: Enrollment provided sat.
Personnel › Training › Familiarization Training
Issued 24 April 2006
Resolved
Conduct underway drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2006
Resolved 26 May 2006
Resolution: drills completed sat.
Personnel › Training › Familiarization Training
Issued 24 April 2006
Resolved
Conduct new to zone inspection
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2006
Resolved 26 May 2006
Resolution: Conducted sat.