Behind this panel: 13 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 13
2 December 2024
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8042011
19 July 2023
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7735901
8 July 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7498693
20 April 2022
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7413702
29 April 2021
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7183981
23 June 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6986469
27 April 2020
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6951420
9 July 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6742193
14 June 2018
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6444826
23 April 2018
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6398357
27 June 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6188989
29 April 2016
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5867078
29 April 2016
Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5867245
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 July 2022
Resolved
Spaces containing propulsion machinery are required to have fixed fire system protection. The fireboy bottle did not have a charge indicated on the pressure gauge. Replace bottle to satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2022
Resolved 25 August 2022
Resolution: Verified re-install of pre-engineered firboy bottle, in the green, all sat. Tested engine shutdown and restart.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2020
Resolved
Each ring life buoy must meet the requirements of found in 46CFR160.050. The vessel does not have a ring buoy onboard that meets these requirements.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 8 July 2020
Resolution: Confirmed that correct ring buoy was installed.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 23 June 2020
Resolved
The stability letter must be kept onboard in a weathertight container and readily available. The vessel does not have their stability letter onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 8 July 2020
Resolution: Verified that stability letter was onboard.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 23 June 2020
Resolved
The COI must be kept onboard in a weathertight container and readily available. The vessel does not have their COI onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 8 July 2020
Resolution: Confirmed that the COI was onboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 July 2019
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted
in the vicinity of the vent.
Vessel operator could not readily operate close/open of the vents.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2019
Resolved 22 July 2019
Resolution: Vessel operator provided photographs of new vents with closures installed on engine cover.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 July 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts and nautical publications.
Vessel operator has a 2004 Inland Navigation Rules.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2019
Resolved 22 July 2019
Resolution: Vessel operator provied photograph on updated 2018 Inland Navigation Rules book.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 27 June 2017
Resolved
Vsl rep had copies of operators' licenses. Issued requirement to see original licenses
Action required: 705 - Other - as specified
Due 11 July 2017
Resolved 10 July 2017
Resolution: Rcvd copies of licenses
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 27 June 2017
Resolved
Cooling line did not have double hose clamps on it.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2017
Resolution: Verified double hose clamps
Lifesaving › Lifebuoys › Serviceable
Issued 11 May 2016
Resolved
Life ring bouy no longer serviceable. Provide life ring bouy prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 May 2016
Resolution: New life ring bouy provided.
Fire Fighting › Fire Bucket › Availability
Issued 11 May 2016
Resolved
Fire buckets missing. Provide fire buckets prior to carrying passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 12 May 2016
Resolution: New 2.5 gal fire buckets provided.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (air intake)
Issued 11 May 2016
Resolved
Air intake piping not properly secured. Repair/replace and ensure proper way of securing intake ventillation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 20 May 2016
Resolution: Ventillation was reinstalled with screws.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 May 2016
Resolved
Provide first aid kit.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 12 May 2016
Resolution: New first aid kit provided.