MAURY USCG vessel records Sign in
← All vessels

W. E. MORRIS

W. E. MORRIS is a 2006 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2006, most recently in April 2025, along with 23 deficiencies.

Records from 2006 to 2025. Most recent: inspection, 11 April 2025.

Built
2006
Last inspected
11 April 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

815627
Flag
UNITED STATES
—
Maury page id
psix-815627

Inspections, by type

Years with a record 17 calendar years (2006–2025)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
3 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 23

11 April 2025 Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8099441
25 April 2024 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7891850
9 May 2023 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7676158
17 April 2023 Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7663159
23 May 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7439951
13 May 2021 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7193464
19 April 2021 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7179744
11 June 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6980289
30 May 2019 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6699058
1 May 2019 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6678680
16 May 2018 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6417720
15 May 2017 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6146239
25 April 2017 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6132575
21 April 2016 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5859317
21 May 2014 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4865125
8 May 2012 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4305728
5 January 2012 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4218815
16 December 2011 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4209291
21 September 2010 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3854226
30 March 2009 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3442624
25 April 2007 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2915264
16 May 2006 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2650051
7 February 2006 COI Inspection · Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2632616

Deficiency record · 23

09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 May 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. First-aid kit onboard was expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2022
Resolved 3 June 2022
Resolution: New first-aid kit purchased and placed onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 May 2022 Resolved
Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. No visual alarm was shown when bilge pump was used in auto/manual.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2022
Resolved 3 June 2022
Resolution: Bilge light to show activation was replaced and test: SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2021 Resolved
Each ring life buoy must be marked with type II retroreflective material. The ring life buoy did not had the approved retroflective tape on. 46CFR185.604
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2021
Resolved 20 May 2021
Resolution: Operator replaced the whole ring buoy.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2021 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the [name withheld] extinguisher bracket was damaged and could not close. 46CFR181.520
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2021
Resolved 20 May 2021
Resolution: Received photos of the new extinguisher mount.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 13 May 2021 Resolved
Air-Cooled propulsion and auxiliary diesel engines installed below deck, as permitted by 182.420 must be fitted with air supply ducts or piping must from the weather deck. One of the vents had a malfuction where the vent would not close in case of fire. 46CFR182.465(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2021
Resolved 20 May 2021
Resolution: Received photo of the replaced vent.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 May 2021 Resolved
Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose. The bilge flexible hose was not double clamped. 46CFR182.720(e)(v)(B)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2021
Resolved 20 May 2021
Resolution: Received photos of the installed rings.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 June 2020 Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing for portable and fixed gas fire extinguishing systems to the marine inspector. Vessel is limited to the carriage of six passengers until portable and fixed fire fighting systems have been serviced.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 June 2020
Resolution: Operator provided proof of servicing for all fire extinguishing systems.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 June 2020 Resolved
On a vessel of 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. The high water level alarm was inoperable.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 July 2020
Resolution: Operator sent a video of functioning high water level alarm.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 June 2020 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The lamp was not illuminating when the bilge pump was operating in auto mode.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 July 2020
Resolution: Operator sent a video of indicator functioning while bilge pump was operating.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 June 2020 Resolved
A submersible electric bilge pump may be used as a power bilge pump provided that a positive shutoff valve is installed at the hull penetration. Not required until next hull exam (April 2021).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2021
Resolved 13 May 2021
Resolution: Observed the installation of the bilge pump shut-off valve.
Navigation › Piloting/Steering › US Coast Pilot
Issued 16 May 2018 Resolved
TJT01- Have on board light list and coastal pilot for Gloucester harbor area by 01JUN18; 46CFR184.420.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2018
Resolved 31 May 2018
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 16 May 2018 Resolved
TJT02- Have name of vessel and retro on life ring by 01JUN18; 46CFR185.604.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2018
Resolved 31 May 2018
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 May 2018 Resolved
TJT03- Provide a cover for battery box by 01JUN18; 46CFR183.350(e).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2018
Resolved 31 May 2018
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 16 May 2018 Resolved
TJT04- Provide proof of EAP training for Drug Program by 01JUN18; 46CFR16.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2018
Resolved 31 May 2018
Operations/Management › Drills/Instruction › Safety Orientation
Issued 16 May 2018 Resolved
TJT05- Provide emergency instructions and post by 01JUN18; 46CFR185.510.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2018
Resolved 31 May 2018
Lifesaving › Lifebuoys › Serviceable
Issued 15 May 2017 Resolved
Provide new life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2017
Resolved 24 May 2017
Resolution: Recieved photo of new lifering.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 15 May 2017 Resolved
Provide drug and alcohol records.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 May 2017
Resolved 24 May 2017
Resolution: Recieved documentation of compliance with drug and alcohol program.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 25 April 2016 Resolved
water light, battery not serviceable and seal broken light had water inside it. 46CFR180.70 by 10MAY16.
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 13 May 2016
Resolution: Received pictures from rep to prove purchas of new light.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 May 2012 Resolved
Both fixed and portable fire fighting extinguishers are not serviced up to date. Provide proove of servicing by authorized personel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2012
Resolution: Provided proove of servicing by authorized personel for both fixed and portable fire fighting extinguishers.
Documentation › Certificates/Documents › FCC SSL
Issued 8 May 2012 Resolved
FCC SSL not available for inspection. Provide FCC SSL
Action required: 705 - Other - as specified
Due 8 June 2012
Resolved 24 May 2012
Resolution: Provided FCC SSL.
Documentation › Certificates/Documents › Stability Letter
Issued 16 December 2011 Resolved
THE VESSEL'S OWNER/OPERATOR HAS NOT REQUESTED AN INITIAL OR UPDATED STABILITY LETTER OR HAS NOT CERTIFIED COMPLIANCE WITH THE REVISED STABILITY CRITERIA FOR ASSUMED AVERAGE WEIGHT PER PERSON (AAWPP) OF 185 POUNDS. BASED UPON A WEIGHT RATIO CALCULATION, THE VESSEL'S CAPACITY IS THEREFORE LIMITED TO: 18 PERSONS (PASSENGERS AND CREW) 46 CFR 170.090
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 5 January 2012
Resolution: Vessel''s owner/operator submitted stability change request letter to Sector Boston Marine Inspections for weight ratio reduction.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 21 September 2010 Resolved
Provide and install 1 B-II portable fire extinguisher.
Action required: 705 - Other - as specified
Due 28 September 2010
Resolved 27 September 2010
Resolution: Vessels owner installed the B-II fire extinguisher as required.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 May 2006 Resolved
Conduct new to zone inspection, including all drills and DAPI, FCC and Master's certificates prior to carriage of pax.
Action required: 705 - Other - as specified
Due 8 May 2006
Resolved 29 June 2006

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.