MAURY USCG vessel records Sign in
← All vessels

AMSTEL TRADER

AMSTEL TRADER is a 2003 freight ship. The Coast Guard has recorded 32 inspections since 2006, most recently in January 2016, along with 12 deficiencies and 5 operational controls.

Records from 2006 to 2016. Most recent: inspection, 25 January 2016.

Built
2003
Last inspected
25 January 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9264776 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
815629
Flag
NETHERLANDS
—
Maury page id
psix-815629

Inspections, by type

…with no type recorded10
Years with a record 8 calendar years (2006–2016)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6704 - Convention (Subpart B), Gross Ton
8015 - Dead Weight, Ton
3557 - Simplified, Net Ton
3557 - Convention (Subpart B), Net Ton
6704 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

25 January 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5802628
8 October 2014 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5001289
16 May 2014 ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4860017
16 December 2011 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4209664
12 August 2011 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4112257
4 November 2010 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3884695
21 October 2010 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3876350
23 September 2010 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3855558
7 September 2010 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3843958
22 March 2010 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3700601
12 March 2010 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3693875
12 February 2010 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3676888
10 February 2010 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3678012
28 January 2010 COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3671762
26 January 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3670002
17 July 2009 Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3536638
3 July 2009 COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3521982
13 March 2009 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3432944
27 February 2009 COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3424416
11 September 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3322758
8 June 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2976566
5 January 2007 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2850839
4 January 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2849832
29 September 2006 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2790197
26 September 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2786960
1 September 2006 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2766867
20 July 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2718819
24 June 2006 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2690303
22 June 2006 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2687709
22 June 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2688326
21 May 2006 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2654491
24 April 2006 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2632724

Deficiency record · 12

Construction/Loadline › Structures › Air Pipe
Issued 11 August 2011 Resolved
THE EXPOSED PARTS OF THE PIPES SHALL BE OF SUBSTANTIAL CONSTRUCTION... SATISFACTORY MEANS, PERMANENTLY ATTACHED, SHALL BE PROVIDED FOR CLOSING THE OPENINGS OF THE AIR PIPES. NUMEROUS TANK VENT FITTINGS ON THE MAIN DECK SHOW SIGNIFICANT CORROSION.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 12 August 2011
Electrical › Electric Supply System (service) › Cable
Issued 11 August 2011 Resolved
ALL ELECTRICAL APPARATUS SHALL BE SO CONSTRUCTED & SO INSTALLED AS NOT TO CAUSE INJURY WHEN HANDLED IN THE NORMAL MANNER. JUNCTION BOXES MOUNTED ON VENTILATION PIPING ARE CORRODED & WASTED, EXPOSING WIRES THROUGHOUT VARIOUS LOCATIONS ON DECK.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 30 December 2011
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 August 2011 Resolved
NOT LESS THAN ONE HALF OF THE TOTAL NUMBER OF LIFEBUOYS SHALL BE PROVIDED WITH LIFEBUOY SELF-IGNITING LIGHTS BROKEN THROUGHOUT DECK.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2011
Lifesaving › Rescue Boat › Propulsion Engine
Issued 11 August 2011 Resolved
CARGO SHIPS SHALL CARRY AT LEAST ONE RESCUE BOAT COMPLYING WITH SECTION 5.1 OF THE CODE. PROVISION SHALL BE MADE FOR AHEAD AND ASTERN PROPULSION OF THE LIFEBOAT. RESCUE BOAT ENGINE WILL NOT ENGAGE AND GO FORWARD AND ASTERN.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2011
Engineering › Fuel Oil Service System › Ventilation
Issued 11 August 2011 Resolved
THE MACHINERY SHALL BE OF A DESIGN & CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. FUEL OIL PURIFIER IN ENGINE ROOM HAS A VENTILATION HOSE ATTACHED TO IT RUNNING FROM ENGINE ROOM VENTILATION. THE HOSE IS JUST WIRED ON TO PREVENT OVERHEATING OF THE PURIFIER. PARTS ARE ON ORDER FOR REPAIR.
Action required: 15 - Rectify deficiencies by next port
Resolved 30 December 2011
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 11 August 2011 Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS. THE FOLLOWING REQUIREMENTS SHALL BE MET: IGNITION SOURCES SHALL BE SEPARATED FROM COMBUSTIBLE MATERIALS. NUMEROUS OILY RAGS & CARDBOARD BOXES WERE SCATTERED THROUGHOUT ENGINE SPACE, ESPECIALLY CONCENTRATED AROUND FUEL OIL PURIFIER.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2011
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 11 August 2011 Resolved
THE MACHINERY SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. THE VALVE FOR THE EMERGENCY GENERATOR FUEL TANK FUEL FILTERS FROM THE DAY TANK IS NOT OPERATING AS DESIGNED. VALVE HANDLE IS TIED IN PLACE WITH RAG.
Action required: 15 - Rectify deficiencies by next port
Resolved 30 December 2011
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 29 April 2006 Resolved
One SCBA inoperable. Provide two firemans outfits IAW Solas Ch II-2 Reg 10.10.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2006
Resolution: Vessel purchased new SCBA and filled with air prior to departure.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 29 April 2006 Resolved
Provide oil pollution placard IAW 33 CFR 155.450
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 May 2006
Resolution: Corrected to the satisfaction of attending Coast Guard Inspector with new placards
Documentation › Markings/Placards › Garbage Placard
Issued 29 April 2006 Resolved
Provide garbage placard IAW Marpol Annex V/Reg 9
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 April 2006
Resolution: Vessel posted garbage placards IAW Marpol Annex V/Reg. 9 in the designated areas.
Documentation › Markings/Placards › Garbage Placard
Issued 29 April 2006 Resolved
Provide sewage pacard IAW 33 CFR 159.59
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 June 2006
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 29 April 2006 Resolved
Provide steering gear block diagram IAW Solas Ch. V Reg. 26.3.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 May 2006
Resolution: Corrected to the satisfaction of attending Coast Guard Inspector

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.