MAURY USCG vessel records
← All vessels

KAYTOS

KAYTOS is a 2006 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in June 2025, along with 20 deficiencies — 1 with no resolution recorded —.

Records from 2016 to 2025. Most recent: inspection, 9 June 2025.

Built
2006
Last inspected
9 June 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 June 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD2097
815772
Flag
UNITED STATES
Maury page id
psix-815772

Documentation record

Registered dimensions (L × B × D)29.9 ft × 9.5 ft × 3.5 ft
Registered tonnagegross 6 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALUMINUM CHAMBERED BOATS INC · BELLINGHAM, WA, UNITED STATES · built 2006
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portAUKE BAY, AK
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Gross Ton
6 - Simplified, Net Ton
5 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

9 June 2025 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8148702
17 June 2024 Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7936790
25 January 2024 Administrative Inspection · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7854293
22 May 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7692597
15 August 2022 Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7534782
7 April 2022 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7429546
27 April 2021 COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7184022
26 May 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6961350
15 April 2020 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6943116
3 June 2019 Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6702806
10 May 2018 Annual Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6420706
1 June 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6152449
17 July 2016 Type not recorded
No type recorded · Station Juneau · USCG Arctic District (CGD-A) · Activity 5942887
2 June 2016 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5896681
23 May 2016 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5886770
18 April 2016 Hull Examination · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5857154

Deficiency record · 20

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 June 2025 No resolution recorded
A sensor must be located above the expected bilge water level in the following locations: (2) The lowest part of a space containing a fuel tank when separate from the machinery space. Vapor detection system is located on top of gasoline fuel tank. Re-locate to lower location to meet requirement. 46CFR182.480(e)(2) Deficiency to be resolved prior to 2026 operating season.
Action required: 705 - Other - as specified
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 9 June 2025 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The FCC-licensed technician must use the latest FCC Information Bulletin, How to Conduct an Inspection of a Small Passenger Vessel. Radiotelephone certificate did not include all communication equipment onbaord. On-board EPIRB was not checked off on the certificate. 47CFR80.903
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 June 2025
Resolution: Certificate updated.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 June 2024 Resolved
A sensor must be located above the expected bilge water level in the following locations:(2) The lowest part of a space containing a fuel tank when separate from the machinery space. Vapor detection system is located on top of gasoline fuel tank. Re-locate to lower location. 46CFR182.480(e)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2024
Resolution: Received photo new vapor detector installation location. Sniffer was moved from the top of the tank to the bottom
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 17 June 2024 Resolved
Every ship subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC licensed technician in accordance for 80.59 once every five years. Radiotelephone certificate did not include all communication equipment onboards. On-board EPIRB was not checked off on the certificate. 46CFR80.903
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 July 2024
Resolution: O/O provided FCC cert with EPIRB checked off.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 22 May 2023 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have a light to indicate discharge. The port fireboy light did not light when tested. Repair or install new light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2023
Resolution: New port fireboy indicator light installed, ops check good.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 May 2023 Resolved
Gauges to indicate engine revolutions per minute (RPM), must be provided for all propulsion engines installed in the vessel. stbd Engine RPM gauge not functional. Reapir/replace RPM gauge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2023
Resolution: Identified loose wire behind dash, repaired and RPM gauge works.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 May 2023 Resolved
A hatch exposed to the weather must be watertight. The aft deck hatch is missing portions of gasket and gasket glue is failing. Replace/renew gasket on hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 June 2023
Resolution: gasket renewed.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 22 May 2023 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Conduct drills with a different crew in presence of Marine Inspector.
Action required: 705 - Other - as specified
Due 5 June 2023
Resolved 5 June 2023
Resolution: conducted drills, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 May 2021 Resolved
The life ring buoy floating light battery was expired. Provide new battery. No night time operations until deficiency is rectified.
Action required: 705 - Other - as specified
Due 20 May 2021
Resolved 7 June 2021
Resolution: Received email with picture of new battery installed.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 3 June 2019 Resolved
Hydrostatic release for life raft was improperly installed. Install hydrostatic release properly.
Action required: 10 - Deficiency Rectified
Resolved 3 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 June 2019 Resolved
Renew battery for life ring floating light prior to conducting nighttime operations.
Action required: 705 - Other - as specified
Resolved 14 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 June 2019 Resolved
Replace unservicable ring bouy.
Action required: 10 - Deficiency Rectified
Resolved 3 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 June 2019 Resolved
Properly mark vessel's name on ring bouy.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 June 2019
Navigation › Piloting/Steering › Marine Charts
Issued 15 May 2018 Resolved
Provide updated navigational charts for operating area - 46 CFR 184.420 - 22May2018
Action required: 705 - Other - as specified
Due 22 May 2018
Resolved 15 May 2018
Resolution: Operator provided new charts.
Lifesaving › Lifebuoys › Serviceable
Issued 10 May 2018 Resolved
Replace unservicable lifebuoy - 46 CFR 180.70 - 22 May 2018
Action required: 705 - Other - as specified
Due 22 May 2018
Resolved 31 May 2018
Resolution: New lifebuoy provided.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 1 June 2017 Resolved
Alarm panel for gasoline vapor detection system non-functional.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2017
Resolution: Attended vessel to witness new alarm panel, all sat.
Navigation › Piloting/Steering › Marine Charts
Issued 1 June 2017 Resolved
Charts onboard not up to date with LNM. Replace or correct necessary charts.
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 28 June 2017
Resolution: Verified up to date nautical charts onboard.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 1 June 2017 Resolved
Provide enrollment letter from consortium.
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 28 June 2017
Resolution: Master sent drug consortium enrollment letter.
Fire Fighting › Remote Fuel Shutoff › General
Issued 23 May 2016 Resolved
Properly label location of the aft emergency F/O shut off valves.
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 2 June 2016
Resolution: Owner re stenciled location of the emergency fuel shut off valves.
Engineering › Fuel Oil Service System › Hose
Issued 18 April 2016 Resolved
Properly bond fuel tank fill pipe to vessels fuel tank that is connected by rubber hose.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 19 April 2016
Resolution: Owner added a bonding wire from the fill pipe to the fuel tank.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.